BF.. SERIES BUFFER TANKS
Open the catalog to page 1BF.. Series Buffer Tanks All chilled water applications where system water volume should be increased… Industrial cooling Machine cooling systems All process cooling applications requiring precise temperature control HVAC cooling High-rise buildings - housing, office buildings, hotels Buildings that require cooling in winter – shopping malls, factories All cooling systems that should be separated by a heat exchanger… Buffer Tanks at var ious capacities from 100 lit ers to 5000 liters easy to install withbaffle plates self insulated 1 We reserve the right to make changes in technical informa
Open the catalog to page 2GENERAL FEATURES BF.. Series Buffer Tanks Specially designed and manufactured to increase water volume in all chilled water applications where additional water volume is needed. Presented for our customers in various capacities from 100 liters to 5000 liters. In order to prevent temperature stratification and provide a homogeneous heat distribution, there are a number of baffle plates within the tank. By this way, the air in the water can easily be separated and discharged from the top of the tank. Delivered as perfectly insulated to minimize energy loss. The outer surface is protected...
Open the catalog to page 3BF.. Series Buffer Tanks In order for a comfort or industrial purpose cooling system to operate properly and efficiently, the total volume of water in the circulation must be above a certain amount. This amount is determined by the system capacity and the desired control accuracy. If the total water volume of the system is below this amount, the thermal capacity should be increased, by installing a TANPERA-BF Series Buffer Tank to the system. The average water temperature in the cooling systems varies with the variation in the load, depending on the rate at which the instantaneous load is...
Open the catalog to page 4DETERMINING THE CAPACITY Application Whether there is a need for a buffer tank in a chilled water system, if there is a need, the capacity of the TANPERA-BF Series Buffer Tank that should be used, may be calculated by the following method. Required Minimum Water Volume (l) = Total Cooling Load (kW) x B (l/kW) The coefficients on the table recommended by the chiller manufacturers can be used to calculate the Minimum Water Volume required for the system. After that, System Active Water Volume should be calculated. Here the volume that the account needs to participate in, is the volume of the...
Open the catalog to page 5BF.. Series Buffer Tanks Function of the TANPERA-BF Series Buffer Tank is to prevent over-switching of the compressor and also to prevent excessive fluctuations in the water temperature going to the system. For this reason, the position of the tank on the chilled water circuit should also be suitable for the purpose of use in the system. TANPERA-BF SERIES BUFFER TANK In typical comfort applications, where the main purpose is to prevent over-switching of the compressor, it is advisable to put the buffer tank before the chiller. TANPERA-BF SERIES BUFFER TANK If the tank is used in an...
Open the catalog to page 6BF.. Series Buffer Tanks Product Type Code Buffer tank type code Technical Specifications Capacity : 100 - 5000 liter Total storage capacity (liters) Designated use : Hot water not exceeding 90°C Nominal operating pressure (bar) Operating pressure : 10 bar Position; V: Vertical, H: Horizontal Mounting position : Vertical (optionally: Horizontal) Coating : Two layers of anticorrosion paint on the outside Insulation : 80 mm thick open cell soft polyurethane Protective sleeve : Vinyl sheath Structural Capacity Group Liters
Open the catalog to page 7^ PLATE HEAT EXCHANGERS V STORAGE WATER HEATERS WITH INDIRECT PIPE COIL V ELECTRIC STORAGE WATER HEATERS 4 DOMESTIC HOT WATER STORAGE TANKS V PACKAGE TYPE DOMESTIC HOT WATER SYSTEMS BUFFER TANKS EXPANSION TANKS J DEAERATORS - DIRT SEPERATORS V HYDROLIC SEPERATORS The great white heron can stand for a long time in the cold water as it can perform an effective heat exchange between the blood coming from the heart at 40°C and the blood returning from the feet at 1°C. v TANPERA A.§. §eyhli Mah. Ankara Cad. No: 380/C 34906 Pendik - istanbul / TURKEY +90 216 482 11 88 - info@tanpera.com.tr -...