Specifications:
The document outlines the specifications for a current sensor, including terminal numbers, dimensions, and weight. The primary nominal current is specified for two types: 50A and 100A. Measuring resistance varies with Vcc values of ±12V and ±15V. The output current is 25mA or 50mA with a turn ratio of 1:2000. Output current accuracy is ±0.25%, excluding offset current, which is ≤ ±0.15mA. Maximum current is specified for a 10-second operating time, with different values depending on resistance load (RL). Power supply voltage ranges from ±12V to ±15V, with consumption current ≤ ±16mA. Response time is ≤ 0.5μs at a di/dt of 100A/μs. Thermal drift of gain and offset are specified, along with hysteresis error and insulation properties.

Procedures and Standards:
The document includes important notices regarding the use of the product. It is intended for general electronic applications and not for special applications requiring high reliability, such as medical or transportation equipment. Users are advised to ensure safety in their designs to prevent accidents. The document disclaims responsibility for any rights violations or damages incurred from special applications unless specified.

Recommendations:
Users should verify the most up-to-date information before using the product. The product is not designed for special environments, such as exposure to liquids, corrosive gases, or strong electromagnetic fields. It is not radiation-resistant, and the document prohibits reproduction without permission.

Key Data from Tables and Diagrams:
The document provides detailed dimensions and tolerances for the sensor, with a typical weight of 26g. It includes a diagram with terminal numbers and dimensions in millimeters. The insulation voltage is AC5000V for 1 minute, and insulation resistance is ≥500MΩ at DC500V. Operating temperature ranges from -40℃ to +85℃, and storage temperature from -40℃ to +90℃.
See more

Catalog excerpts

Servo system Current-out type dv/dt improvement type S23P M2 series_S23P50D15M2-1

電流センサ関連 CURRENT SENSORS 磁気平衡式電流出力型 dv/dt 特性強化タイプ Servo system Current-output type dv/dt improvement type 項 目 Spec 定格電流 Primary norminal current 測定抵抗 (If=±ADC, Ta=85℃) Measuring resistance 定格出力電流 Output current 出力電流精度 Output current accuracy 最大電流 通電時間 Operating time: ≦10sec Maximum current Vcc=±15V 出力直線性 Output linearity 電源電圧 Power supply voltage ±12V ±5%〜±15V ±5% (Ratad output current is restricted by Vcc) 消費電流 Consumption current didt 応答速度 @90% of If Response time 出力電流温度係数 Thermal drift of gain オフセ ト電流温度係数 ッ Thermal drift of offset ヒステ シス誤差 リ Hysteresis error 絶縁耐圧 Insulation voltage AC5000V, 1分間(感応電流0.5mA) 1次 ⇔ 2次間 AC5000V for 1 minute (Sensing current 0.5mA) Primary ⇔ Sacondary 絶縁抵抗 Insulation resistance 動作温度範囲 Ambient Operating temperature 保存温度範囲 Ambient storage temperature 2次側コイル抵抗値 Secondary coil resistance ※1 オフセ ト電流はコアヒステ シス除去後の値と ッ リ する。 Offset current value is after removal of core hysteresis. ※ UL承認条件につき しては、 ま 別紙を参照願います。  Please refer to the another sheet about conditions of UL Recognition. Note Unless otherwise specified, tolerances shall be ±0.5mm Unit is [mm]

 Open the catalog to page 1
Servo system Current-out type dv/dt improvement type S23P M2 series_S23P50D15M2-2

電流センサ関連 CURRENT SENSORS ご注意 Important Notice 1. 本書の記載内容は、改良などにより予告なく変更することがありま す。 ご使用の際には、最新の情報であることをご確認下さい。 2. 本製品は一般的な電子機器家電製品、事務機器、情報機器、通信 端末機器、計測機器、産業機器などへの使用を意図しております。 極めて高度な品質及び信頼性が要求され、その製品の故障や誤動 作が人命・身体に危害を及ぼす機器、装置医療機器、輸送機器、 交通信号制御機器、火災・防犯装置、航空宇宙機器、原子力制御、 燃料制御、車載機器、各種安全装置などの特定用途に使用される ことを目的として設計及び製造されたものではございません。 本資料に個別に記載されている場合を除き、本特定用途に使用され た場合には、お客様または第三者の損害等について当社はいかな る責任も負いかねます。 3. 当社は品質、信頼性の向上に努めておりますが、電流センサはある 程度の確率で機能不具合、故障の発生は避けられません。故障の 結果として、人身事故、火災事故、社会的損傷などを発生させないよ う、使用者の責任において、装置やシステム上での十分な安全設計 と確認を行って下さい。 4. 本書に記載されている動作例および回路例は、使用上の参考として 示したもので、これらに起因する当社もしくは第三者の工業所有権、...

 Open the catalog to page 2

All Tamura Corporation catalogs and technical brochures

  1. S25PxxxD15*

    3  Pages

  2. S26P200D15Y

    3  Pages

  3. S29S1T0D24Z*

    4  Pages

  4. Current Sensors

    111  Pages

  5. L07PxxxS05

    2  Pages

  6. L07PxxxD15S

    2  Pages

  7. L07PxxxD15

    2  Pages

  8. F03PxxxS05

    8  Pages

  9. F01PxxxS05

    7  Pages

*Prices are pre-tax. They exclude delivery charges and customs duties and do not include additional charges for installation or activation options. Prices are indicative only and may vary by country, with changes to the cost of raw materials and exchange rates.