L07PxxxD15

L07PxxxD15

L07PxxxD15

Product catalog summary
Specifications
The document outlines the specifications for a magnetic proportion system with two circuits, designed for use at an ambient temperature of 25°C, with a load resistance of 10kΩ and a power supply voltage of ±15V. The primary nominal current ranges from 3A to 30A, with a saturation current of up to three times the nominal current. The rated output voltage is 4V with a tolerance of ±0.060V, and the offset voltage is ≤ ±0.060V when the current is 0A. Output linearity is maintained within ±1% across the current range. The power supply voltage tolerance is ±5%, and the consumption current is ≤ ±30mA. The response time is ≤ 5μs, and the thermal drift of gain and offset are specified as ≤ 0.1%/°C and ≤ ±2.5mV/°C, respectively. The hysteresis error is ≤ 30mV. Insulation voltage is AC2000V for 1 minute, and insulation resistance is ≥ 500MΩ at DC500V. The operating temperature range is -30°C to +80°C, and the storage temperature range is -40°C to +85°C.
Procedures and Recommendations
The document advises that the product is intended for general electronic applications and is not designed for use in critical applications such as medical devices or nuclear power control. Users are responsible for ensuring the safety and reliability of their designs. The document also provides guidelines for use in special environments, such as exposure to liquids, corrosive gases, or strong electromagnetic fields, and advises against such uses unless thorough safety checks are performed.
Important Notices
The document includes several important notices, including that the content is subject to change without notice, and that the product is not designed to resist radiation. It also states that the document and its contents may not be reproduced without permission from Tamura Corporation.
See more

Catalog excerpts

L07PxxxD15-1

電流センサ関連 CURRENT SENSORS 磁気比例式 2回路タイプ Magnetic Proportion System, 2 Circuits Type カタ ログ品番 Types 項 目 Spec 定格電流 Primary norminal current 飽和電流 Saturation current 定格出力電圧 Rated output voltage 出力直線性 Output linearity (0A〜If) 電源電圧 Power supply voltage 消費電流 Consumption current 出力電圧温度特性 Thermal drift of gain オフセ ト電圧温度特性 ッ Thermal drift of offset didt 応答速度 Response time ヒステ シス誤差 リ Hysteresis error 絶縁耐圧 Insulation voltage AC2000V, 1分間 感応電流0.5mA ⇔ 2次間 1次 AC2000V for 1 minute (Sensing current 0.5mA) Primary ⇔ Sacondary 絶縁抵抗 Insulation resistance 動作温度範囲 Ambient Operating temperature 保存温度範囲 Ambient storage temperature ※1 オフセ ト電圧はコアヒステ シス除去後の値と ッ リ する。  ※2 チャ ンネル毎の値と 他チャ し、 ンネルの入力電流は0Aと する。  ※ UL承認条件につき しては、 ま 別紙を参照願います。 *1 Offset voltage value is after removal of core hysteresis. *2 Shall be each channel's value. Other channel's input current to be 0A. *Please refer to the another sheet about conditions of UL Recognition. Note Unless otherwise specified, tolerances shall be ±0.5mm Unit is [mm]

 Open the catalog to page 1
L07PxxxD15-2

電流センサ関連 CURRENT SENSORS ご注意 Important Notice 1. 本書の記載内容は、改良などにより予告なく変更することがありま す。 ご使用の際には、最新の情報であることをご確認下さい。 2. 本製品は一般的な電子機器家電製品、事務機器、情報機器、通信 端末機器、計測機器、産業機器などへの使用を意図しております。 極めて高度な品質及び信頼性が要求され、その製品の故障や誤動 作が人命・身体に危害を及ぼす機器、装置医療機器、輸送機器、 交通信号制御機器、火災・防犯装置、航空宇宙機器、原子力制御、 燃料制御、車載機器、各種安全装置などの特定用途に使用される ことを目的として設計及び製造されたものではございません。 本資料に個別に記載されている場合を除き、本特定用途に使用され た場合には、お客様または第三者の損害等について当社はいかな る責任も負いかねます。 3. 当社は品質、信頼性の向上に努めておりますが、電流センサはある 程度の確率で機能不具合、故障の発生は避けられません。故障の 結果として、人身事故、火災事故、社会的損傷などを発生させないよ う、使用者の責任において、装置やシステム上での十分な安全設計 と確認を行って下さい。 4. 本書に記載されている動作例および回路例は、使用上の参考として 示したもので、これらに起因する当社もしくは第三者の工業所有権、...

 Open the catalog to page 2

All Tamura Corporation catalogs and technical brochures

  1. S25PxxxD15*

    3  Pages

  2. S26P200D15Y

    3  Pages

  3. S29S1T0D24Z*

    4  Pages

  4. Current Sensors

    111  Pages

  5. L07PxxxS05

    2  Pages

  6. L07PxxxD15S

    2  Pages

  7. F03PxxxS05

    8  Pages

  8. F01PxxxS05

    7  Pages

*Prices are pre-tax. They exclude delivery charges and customs duties and do not include additional charges for installation or activation options. Prices are indicative only and may vary by country, with changes to the cost of raw materials and exchange rates.