ELECTRONICS COMPONENTS

 Open the catalog to page 1
Current Sensors-2

Circuit system / Application notes / Data sheet F-Series, L-Series, S-Series

 Open the catalog to page 2
Current Sensors-3

Group Network - Overseas ■ •Tamura Europe Limited Czech branch • ■ATamura Europe Limited (U.K • ■••Tamura Corporation of Korea • ■ATamura Chemical Korea Co., • ATamura Corporation •Tamura Kaken Corp., Tamura Power • •Tamura Corporation (Thailand), •Tamura Corporation Vietnam • ■ATamura Electronics (Malaysia) SDN.BHD. •Tamura Kaken (Malaysia) SDN.BHD. (Huizhou) Co.,Ltd. (Shenzhen) Co.,Ltd. I Anzen Dengu (Huizhou)Co, Ltd. Electronic components Electronic chemicals / FA systems Information Equipment # : General and administratis • ■A Shanghai Xiangle Tamura Electro Chemical Industry Co., Ltd. •...

 Open the catalog to page 3
Current Sensors-4

Outline / Applications / Features The current sensor is a sensor to measure the current as its name. However, The current is various. There is a current value up to 10k amperes treated in the power plant from 1 mA, and the shape of current waves also has AC, DC, and AC + DC. Since a method and a structure the best in each measuring object are different, there are also various current sensors. Tamura supplies the sensor using the Hall-Effect system for measuring the current value from several amperes to several kilo-ampere. The Hall-Effect current sensor measures the magnetic flux produced in...

 Open the catalog to page 4
Current Sensors-5

Applications of Current Sensor Series (Example)

 Open the catalog to page 5
Current Sensors-6

Current Sensor / Guide map

 Open the catalog to page 6
Current Sensors-7

Current Sensor / Guide map

 Open the catalog to page 7
Current Sensors-8

TXV^rM^J^ CURRENT SENSORS Circuit system Tamura offers multiple current sensor options to meet application requirements: Open Loop or Linear type (magnetic proportionality); Closed Loop or Servo-type (magnetic balance); Flux-Gate (magnetic equilibrium). Open loop If the current is applied to the cable, the magnetic field proportional to the current in surroundings of the cable is generated on Ampere's rule. The magnetic core is set in surroundings of the cable to improve the sensitivity. The Magnetic field is converted into the voltage by the linear type - hall element is placed in the gap of...

 Open the catalog to page 8
Current Sensors-9

TXV^^l2l^ CURRENT SENSORS MUlMlliMH 1/1 I 2 114121 Application notes <General Considerations> 1. The sensor uses polar electronic components. When the polarity of the power supply is mistaken, the sensor is damaged. 2. Static electricity or excessive voltage can increase an offset voltage in the Hall element, and cause offset voltage to change. Please exercise care in handling and application. 3. In order to prevent the influence of noise, the use of twisted cable or shielded cable for the output line is recommended 4. If using this device within a magnetic field generated by other devices, the...

 Open the catalog to page 9
Current Sensors-10

TXVWl2l^ CURRENT SENSORS ^KSfflE] 1/1 Ml 1405 Part numbering system O Model (3 figures or 4 figures) Open loop system (Magnetic Proportion System) Closed loop system (Servo system) Fluxgate system Open loop system - One chip ASIC I Mounting configuration (1 figure) P : Through Hole Mounting Device M : Surface Mount Device I Rated current (3 figures) 0 Control power supply type (1 figure) S : Single supply D : Dual supply 0 Power supply voltage (2 figures) 0 Special specification (4 figures_MAX.)

 Open the catalog to page 10
Current Sensors-11

Important Notice 1. The content of this information is subject to change without prior notice for the purpose of improvements, etc. Ensure that you are in possession of the most up-to-date information when using this product. 2. This product is intended to be used in general electronics applications (electric home appliances, business equipment, information equipment, communication terminal equipment, measuring devices, industrial equipment, and so on). This product is neither intended nor warranted for use in following Special application (such as for medical devices, transportation equipment,...

 Open the catalog to page 11
Current Sensors-12

According to UL508 standard and CSA C22.2 No.14 standard Note> Models F01P; followed by 006, 015, 025 or 050, followed by S05, may be followed by D, or L, may be followed by slash and any numbers from 01 through 99 or blank. Models F02P; followed by 006, 015, 025 or 050, followed by S05, may be followed by D, L, -P0, - P1, -P2, -P3, -P4, -P5, -P6, -PI, -P8, -P9, -PA, -PB, -PC, -PD, -PE or-PF, may be followed by slash and any numbers from 01 through 99 or blank. Models F03P; followed by 006, 015, 025 or 050, followed by S05, may be followed by D, L, -P1, -P2, -P3, -P4, -P5, -P6, - P7, -P8, -P9,...

 Open the catalog to page 12
Current Sensors-13

CURRENT SENSORS Note> Models F01P; followed by 006, 015, 025 or 050, followed by S05, may be followed by D, or L, may be followed by slash and any numbers from 01 through 99 or blank. Models F02P; followed by 006, 015, 025 or 050, followed by S05, may be followed by D, L, -P0, P1, -P2, -P3, -P4, -P5, -P6, -P7, -P8, -P9, -PA, -PB, -PC, -PD, -PE or -PF, may be followed by slash and any numbers from 01 through 99 or blank. Models F03P; followed by 006, 015, 025 or 050, followed by S05, may be followed by D, L, -P1, -P2, -P3, -P4, -P5, -P6, P7, -P8, -P9, -PA, -PB, -PC, -PD, -PE or -PF, may be followed...

 Open the catalog to page 13
Current Sensors-14

CURRENT SENSORS Ratings - Electrical Series Primary (Feed - through) Secondary (Sensing) Primary (Feed - through) Secondary (Sensing) Input

 Open the catalog to page 14
Current Sensors-15

CURRENT SENSORS Note> Models F01P; followed by 006, 015, 025 or 050, followed by S05, may be followed by D, or L, may be followed by slash and any numbers from 01 through 99 or blank. Models F02P; followed by 006, 015, 025 or 050, followed by S05, may be followed by D, L, -P0, P1, -P2, -P3, -P4, -P5, -P6, -P7, -P8, -P9, -PA, -PB, -PC, -PD, -PE or -PF, may be followed by slash and any numbers from 01 through 99 or blank. Models F03P; followed by 006, 015, 025 or 050, followed by S05, may be followed by D, L, -P1, -P2, -P3, -P4, -P5, -P6, P7, -P8, -P9, -PA, -PB, -PC, -PD, -PE or -PF, may be followed...

 Open the catalog to page 15
Current Sensors-16

CURRENT SENSORS The descriptions are directed from UL. CAUTION / Notice CAUTION: Do not wrap the primary conductor around the core part of the product to increase measured current. / - - / Notice: Do not wrap the primary conductor around the core part of the product for preventing to reduce the required Spacings. - / Notice: Do not wrap the primary conductor around the core part of the product for preventing to reduce the required Spacings. The maximum temperature at case should not exceed 140 C by the case’s insulation performance. - / Notice: Do not wrap the primary conductor around the core...

 Open the catalog to page 16

All Tamura Corporation catalogs and technical brochures

  1. S25PxxxD15*

    3  Pages

  2. S26P200D15Y

    3  Pages

  3. S29S1T0D24Z*

    4  Pages

  4. L07PxxxS05

    2  Pages

  5. L07PxxxD15S

    2  Pages

  6. L07PxxxD15

    2  Pages

  7. F03PxxxS05

    8  Pages

  8. F01PxxxS05

    7  Pages

*Prices are pre-tax. They exclude delivery charges and customs duties and do not include additional charges for installation or activation options. Prices are indicative only and may vary by country, with changes to the cost of raw materials and exchange rates.