Catalog excerpts
Tamson Instruments Specification sheet Specifications TV7000LT Tamson Visibility bath 70 Litres Low Temperature - ASTM D445 Used materials inside bath Standard C,F on request Reading Setting Depth bath Top lid stainless steel Integrated cooling High precision better than ± 0.02°C Large windows, no condensation Easy to operate RS232 communication Bath volume Noise level General The TV7000LT is a unique visibility bath with wide dimensions. Span The bath temperature can be set from -40°C to a maximum of +100C in steps of 0.01°C. An integrated cooling system is able to lower the bath temperature down to minus 40°C within approximately four hours. The cooling power is controlled over four stages, so that the heat removal capacity is trimmed to the desired set point temperature, saving up to 50% of energy. Accuracy Overall accuracy is better than ± 0.02°C, over the whole temperature range. Ambient temperature drift <0.003°C/°C. The homogeneity is better than 0.02°C. Drift, accuracy and homogeneity were measured with methanol as bath medium and are true min-max values found over eight hours. Due to its wide temperature range the bath can be used for multiple purposes varying from sub-zero temperature viscosity determination to calibration of sensors or thermometers. The large windows show the bath contents clearly. The windows are heated preventing build-up of condensate. The bath can be emptied via a drain. If bath fluid expands at higher set point temperatures overflow of bath is protected via a drain. A LED fluid level indicator alarms when fluid level is too low. Safety The bath conforms to CE regulation. Further it is equipped with multiple safety features in order to guarantee safe around the clock operation. A mechanical safety thermostat protects the bath against high temperatures and will automatically reset itself after switching the bath off and on again. In case of over temperature electronics and motor are switched off. The pump motor is protected against mechanical overload via a resettable fuse.
Open the catalog to page 1Tamson Instruments Specification sheet Specifications TV7000LT Tamson Visibility bath 70 Litres Low Temperature - ASTM D2162 Cooling down (methanol used as bath liquid) 20 Time [hrs:min] 0 Temperature stability (methanol used as bath liquid) Set point = -40°C Max Delta = 0.04°C Time [hrs:min]
Open the catalog to page 2Tamson Instruments Specification sheet Specifications TV7000LT Standard cover and Optional cover TV7000LT is standard included with: Description Cover with 7 openings: - 7 x ø51 mm opening - 2 x ø12.5mm opening for thermometer Optional covers for TV7000LT: Description Cover with 8 openings: - 8 x ø51 mm opening - 2 x ø12.5mm opening for thermometer Cover with 8 openings: - 8 x ø60 mm opening - 2 x ø12.5mm opening for thermometer 23T2402 8 * lid for ø 60 mm opening Cover with 7 openings: - 4 x ø51 mm opening - 3 x ø60 mm opening - 2 x ø12.5mm opening for thermometer
Open the catalog to page 3Tamson Instruments Specification sheet Specifications TV7000LT Accessories Tamson TT3B thermometer with external probe, three decimal reading, precision ± 0.01°C, short PT-100 probe with range -40 .. +140°C including a works calibration certificate. (Please see specification sheet "TT3B thermometer") Adapter to insert a TT3B thermometer in the opening of the cover Viscosity Accessories Please see specification sheet “Viscosity Accessories”
Open the catalog to page 4All Tamson Instruments BV catalogs and technical brochures
-
TC16 Bath/circulator
3 Pages
-
TCC-B D97 D2500 bath
4 Pages
-
TC16 ASTM D2440 Apparatus
3 Pages
-
Filtration kit
6 Pages
-
TC16 ASTM D1796 bath
2 Pages
-
ASTM D1298 density apparatus
10 Pages
-
TV4000AKV EASY