TCC-B D97 D2500 bath
4Pages

{{requestButtons}}

Catalog excerpts

TCC-B D97 D2500 bath - 1

Tamson Instruments Specification sheet Adjustable Cloud and Pour Point Bath ASTM D97 - ASTM D2500 - ISO 3015 - ISO 3016 - IP 15 - IP 219 Used materials inside bath Pump pressure [mBar] Bath volume Drain to empty bath Wheels fitted for easy transport Compact, low noise Auto tune, high precision Position for six jackets (TLC40-14) Position for four jackets (TCC-B) Control mechanism With the compressor running continuously, the fluid temperature is regulated through an electronic controlled heater. Span The TLC40-14 operates from -40°C to +20C (40°F..68F). The TCC-B operates from -88°C to +20°C (-126°F to +68°F). Depth bath Cooling medium The used cooling system is ozone friendly and doesn’t contain any CFK/HCFK gas. Opening bath General Apparatus to determine the cloud and pour point manually. The TLC40-14 or TCC-B are single and adjustable circulator baths with position for six or four jackets. The pour point describes a procedure for testing the fluidity of a petroleum product at a temperature. The cloud point is defined as the temperature of a liquid specimen when the smallest observable cluster of wax crystals first appears upon cooling. Tamson is also supplying a liquid bath to preheat the sample to 48 ± 1.5°C or 12°C above the expected pour point, please see table 3. Heat removal * 24T0399: Optional pump (85~260V) pressure max 1 Bar, flow max 16 ltrs/min. Accuracy The set point is adjustable in steps of 0.1. The overall system accuracy is better than  0.1C. The temperature readout is standard available in C, on request in F. Pump A pressure pump provides circulation in the bath or via an external circuit. The pump pressure is 300 mBar and 10 liters per minute (no counter pressure) for TLC40-14. For the TCC-B the pump pressure is 1000 mBar and 16 liters per minute. With the TCC-B, the pump speed can be adjusted. Safety The bath conforms to CE regulations. It also is equipped with a mechanical adjustable and resettable safety thermostat to guarantee safe around the clock operation.

Open the catalog to page 1
TCC-B D97 D2500 bath - 2

Tamson Instruments Specification sheet Adjustable Cloud and Pour Point bath Accessories Table 1: Necessary accessories TLC40 TCC-B -14 Insulated cover for six positions with insulated lids. Insulated cover for four positions with insulated lids. Table 2: Accessories TLC40 TCC-B Description -14 Test jar for cloud and pour point, case of 24 1 pieces. 6 Test jar for cloud and pour point, 1 piece. Felt gasket (pack of ten pieces). Felt disk (pack of ten pieces). Cork for test jar (P/N 31T0012 or 09T0142), pack of ten pieces. Cork for bath thermometer, pack of ten pieces. ASTM S5C thermometer...

Open the catalog to page 2
TCC-B D97 D2500 bath - 3

Tamson Instruments Specification sheet Adjustable Cloud and Pour Point bath Bath to preheat samples Table 3: Bath to preheat samples to 48 ± 1.5°C or 12°C above the expected pour point P/N Description TC16 circulator, including cover with six ø 51mm openings with lids and a thermometer opening. 230V/5060Hz TC16 circulator, including cover with six ø 51mm openings with lids and a thermometer opening. 115V/60Hz Cork for bath thermometer, pack of ten pieces. Thermometer similar to ASTM 61C with special lowhazardous filling and works certificate at 100°C.

Open the catalog to page 3
TCC-B D97 D2500 bath - 4

Tamson Instruments Specification sheet Adjustable Cloud and Pour Point bath Graphs Temperature stability (methanol used as bath liquid) Set point = 0°C 0°C Max Time [hrs:min] Cooling down TLC40-14 (methanol used as bath liquid) Cooling down TCC-B (methanol used as bath liquid) Time [hrs:min]

Open the catalog to page 4