1. Catalogs
  2. TAKACHI Electronics Enclosure Co., Ltd.
  3. TMB series - TERMINAL JUNCTION BOX

TMB series - TERMINAL JUNCTION BOX

TMB series - TERMINAL JUNCTION BOX
1 / 18 PagesView full catalog

TMB series - TERMINAL JUNCTION BOX

Product catalog summary
Terminal Junction Box Specifications:
The terminal junction box includes a built-in terminal block with IP65 protection, available in ABS and glass fiber-filled polycarbonate. Models in the TMB series offer 4, 6, and 10 poles with metric knock-outs for M20 cable glands.
Installation Instructions:
Knock-out covers can be removed using a flathead screwdriver and a hammer.
Terminal Block Specifications:
Rated for 400V and 17.5A, suitable for 1.5mm² wire with a standard tightening torque of 0.8N·m.
Technical Data:
Features IP65 protection, operating temperature from -10°C to +60°C, with recommended torque varying by model.
Components:
Includes a top cover, body, gasket, conductive plate, terminal screws, and cover screws, with materials differing by model.
Dimensions and Models:
Detailed dimensions are available online for each model.
Accessories:
Optional parts include shorting bars, cable glands, and mounting brackets.
Weatherproof Cable Gland Specifications:
The RMW series is designed for outdoor use with IP67 protection, featuring a silicone sealing insert and O-ring, operating from -20°C to +80°C.
Polyamide Cable Gland Specifications:
The RM series offers IP67 protection with NBR rubber sealing and O-ring, operating from -20°C to +80°C.
Strain Relief Cable Gland:
The RSP series provides strain relief and waterproofing equivalent to IP67.
Testing and Recommendations:
Includes test results for weatherproofing and torque application recommendations.
Overview:
Technical specifications and guidelines for RSP, AG, and RMH series cable glands, including dimensions, materials, recommended torque values, and installation instructions.
Specifications:
  • RSP Series: IP68 protection, suitable for cable diameters from 2.5mm to 42mm, made from PA6GF, halogen-free.
  • AG Series: IP68 protection, operating from -20°C to +100°C, compliant with EN50262 Ver. A, suitable for uneven surfaces with optional sealing washer.
  • RMH Series: Multi-hole cable gland with IP65 protection, operating from -20°C to +80°C, protecting up to 6 cables.
Recommended Torque Values:
  • RSP Series: Torque varies by cable range, e.g., RSP8-2.5 requires 0.6-0.7 N・m for the cap and 0.4 N・m for the lock nut.
  • AG Series: Torque varies, e.g., AG8-3.5 requires 0.5 N・m for the cap and 1.0 N・m for the lock nut.
Installation Guidelines:
  • Ensure proper tightening to prevent damage and maintain waterproofing.
  • Use tools to prevent co-rotation during tightening.
  • Consider environmental factors like temperature and material hardness.
Materials:
  • Components primarily made from PA6GF, TPE, and NBR materials.
  • Lock nuts not included for M8 and M10 sizes; appropriate thread holes must be drilled.
Additional Notes:
  • DXF/DWG/PDF drawings available online for detailed dimensions.
  • Optional parts like sealing washers and plugs available for specific needs.
See more

Catalog excerpts

TMB series - TERMINAL JUNCTION BOX-1

Technical Data Recommended torque : ■ Terminal junction box with built-in terminal block. ■ ABS and Glass fiber filled polycarbonate types are available. ■ TMB-4P • 6P • 10P is molded with Q21.0mm metric knock-outs for M20 cable glands. ■ To knock out the hole covers, rest a flathead screwdriver at the "A" points, and punch out the knock-outs by hammering on the rear end of the screwdriver handle with a hammer. Applicable crimp terminal R1.25-3.5 Accessories (Optional parts) ^Cover screw material : Stainless steel - 4P, 6P, and 10P models • Nylon - 15PCS, 20PC, and 20PCL models. Shorting bar SBR series See website Cable gland Mounting bracket CK-34Z

 Open the catalog to page 1
TMB series - TERMINAL JUNCTION BOX-2

ABS UL94V-0 Models Product no. / Details Product no. L W H Number of poles Weight (g) ■ Drawings below are reference examples only. DXF/DWG/PDF drawings available on our website. ^021 knock-out also present on opposite side. TMB-6P ^021 knock-out also present on opposite side. TMB-10P ^021 knock-outs also present on opposite side.

 Open the catalog to page 2
TMB series - TERMINAL JUNCTION BOX-4

Accessories (Optional parts) ■ SBR70-10P, SBR85-10P, SBR95-20P, and SBR95-20N can be cut accordingly into required poles. ■ PVC coated. SBR95-20 available in both PVC coated (SBR95-20P) and non PVC coated (SBR95-20N) models. ■ See chart below for suitable box. SBR95 -20P 20P 9.6mm TMA • TMB series (Not applicable for TMB-20P, TMA20P-AS, and TMA30P-AS models) SBR95 -20N 20P 9.6mm TMA • TMB series (Not applicable for TMB-20P, TMA20P-AS, and TMA30P-AS models) Product no. / Feature ■ Pack quantity differs by models. SBR70 - 2P 2P Brass Nickel plated Yes 10 SBR70 -10P 10P Brass Nickel plated Yes 1...

 Open the catalog to page 4
TMB series - TERMINAL JUNCTION BOX-5

Accessories (Optional parts)BCM SERIES BLIND PLUG for BCAS • BCAL ■ Blind plug for BCAS • BCAL when installing hinges and latches. Not usable when using cover screws. Part name Material Color Blind plug ABS White gray Product no. Suitable box Pack of BCM-1 BCAS series (Not available for BCAS050604, 050605 models) 1 CK SERIES STAINLESS STEEL MOUNT BRACKET CK-34Z dimensions ■ CK-34Z model requires the use of MT4-10 screw. CK-34Z Stainless steel SUS304 Barrel finish BCAS series (Not applicable for BCAS050604, 050605 models) - 4 CK-35P Stainless steel SUS304 Barrel finish BCAS050604G, BCAS050605G...

 Open the catalog to page 5
TMB series - TERMINAL JUNCTION BOX-6

■ Weatherproof cable gland equipped with high ultraviolet and degradation resistant silicone sealing insert and O-ring. ■ Recommended to use outdoors where waterproofing is critical. ■ Protection class equivalent to IP67. ■ DXF/DWG/PDF drawings available Please drill a proper thread hole into the enclosure for installation. Cap design varies by size RMW40 or smaller

 Open the catalog to page 6
TMB series - TERMINAL JUNCTION BOX-7

RMW series silicone sealing insert weatherproof test report Object: Cut into a piece of the silicone sealing insert from RMW series and attach it onto an aluminium plate. For comparison, NBR sealing insert from our RM and EPDM sealing insert from another manufacturer is also attached. Testing conditions Equipment : Conditions : 7.5kW Super Xenon Weather Meter SX75 (Suga Test Instruments Co., Ltd.- http://www.sugatest.co.jp/english/) JIS B7754 : 1991 Testing with an authorized Xenon arc lamp weathering test equipment under the conditions denoted below. Irradiance : 180W/m2 at 300-400nm Black Panel...

 Open the catalog to page 7
TMB series - TERMINAL JUNCTION BOX-8

Cable Gland Recommended Torque REFERENCE TABLE - RMW series The table below details the reference tightening torque values recommended for tightening of the cable gland. Excessive tightening may damage, or cause deformation to the cable, or to the cable gland itself. It is recommended to both utilize the table as a reference when tightening, as well as performing actual field testing to ascertain if the product/s are suitable to be used under the required conditions. Precautions should be taken when tightening to prevent damage and deformation of the components. When tightening, the connector...

 Open the catalog to page 8
TMB series - TERMINAL JUNCTION BOX-9

series POLYAMIDE CABLE GLAND ■ Low cost cable glands made from polyamide material. ■ Wide selection, for M8 ~ M63, suitable for 01mm ~ 044 mm cable. ■ High oil resistant NBR rubber sealing and O-ring. ■ Protection class equivalent to IP67. Technical Data Protection class : Equivalent to IP67* Operating temperature : -20°C ~ +80°C *In-house test RM dimensions ■ DXF/DWG/PDF drawings available on our website. Cap design varies by size L H SW ■ Lock nut is not included for RM8S-2.5, 8S-4, and 10S-6 models. Please drill an appropriate thread hole into the enclosure for installation. Product no. /...

 Open the catalog to page 9
TMB series - TERMINAL JUNCTION BOX-10

Cable Gland Recommended Torque REFERENCE TABLE - RM series The table below details the reference tightening torque values recommended for tightening of the cable gland. Excessive tightening may damage, or cause deformation to the cable, or to the cable gland itself. It is recommended to both utilize the table as a reference when tightening, as well as performing actual field testing to ascertain if the product/s are suitable to be used under the required conditions. Precautions should be taken when tightening to prevent damage and deformation of the components. When tightening, the connector...

 Open the catalog to page 10
TMB series - TERMINAL JUNCTION BOX-11

RSP series STRAIN RELIEF CABLE GLAND ■ A total of 14 models available for selection. Protection class : Equivalent to IP67* Operating temperature : -20°C ~ +80°C ■ Strain relief cap protects cables by preventing it from bending beyond its limit and breaking.■ Economical price but high waterproofing capability equivalent to IP67. *In-house test ■ DXF/DWG/PDF drawings available on our website. ■ PA = Polyamide ComponentsProduct no. / Details Product no.

 Open the catalog to page 11
TMB series - TERMINAL JUNCTION BOX-12

Cable Gland Recommended Torque REFERENCE TABLE - RSP series The table below details the reference tightening torque values recommended for tightening of the cable gland. Excessive tightening may damage, or cause deformation to the cable, or to the cable gland itself. It is recommended to both utilize the table as a reference when tightening, as well as performing actual field testing to ascertain if the product/s are suitable to be used under the required conditions. Precautions should be taken when tightening to prevent damage and deformation of the components. When tightening, the connector...

 Open the catalog to page 12

All TAKACHI Electronics Enclosure Co., Ltd. catalogs and technical brochures

*Prices are pre-tax. They exclude delivery charges and customs duties and do not include additional charges for installation or activation options. Prices are indicative only and may vary by country, with changes to the cost of raw materials and exchange rates.