LOW COST IP67 METAL CABLE GLAND ■ Economical metal cable gland. ■ Equivalent to IP67 protection class. ■ Wide selection available from M12 ~ M32. Technical Data Protection class : Equivalent to IP67* Operating temperature : -20°C ~ +80°C *In-house test ■ DXF/DWG/PDF drawings available on our website.
Open the catalog to page 1■ High water protection IP68 (1bar / 30min) metal cable gland. Protection class : IP68 1bar / 30min Operating temperature : -40°C ~ +100°C Compliant with EN50262 Ver. A AGM series Lamellar insert type Thicker sealing insert evenly hold a cable by having a larger holding area. If over-tightened, it can cause the rubber bush or cable to deform, Remains durable even after repeated tightening / loosening. which can allow water to seep in.
Open the catalog to page 2■ DXF/DWG/PDF drawings available on our website. Product no. / Details Product no.
Open the catalog to page 3Cable Gland Recommended Torque REFERENCE TABLE - AGM series The table below details the reference tightening torque values recommended for tightening of the cable gland. Excessive tightening may damage, or cause deformation to the cable, or to the cable gland itself. It is recommended to both utilize the table as a reference when tightening, as well as performing actual field testing to ascertain if the product/s are suitable to be used under the required conditions. Precautions should be taken when tightening to prevent damage and deformation of the components. When tightening, the connector...
Open the catalog to page 4Technical Data Protection class : IP68 2bar / 30min, IP69K Operating temperature : -60°C ~ +100°C Compliant with IEC62444 Var. A ■ Optimal contact spring provides excellent shield contact and the smallest possible transfer impedance. ■ Clawed lock nut makes a good EMC shield contact possible on conductive enclosures. ■ Shape of the contact spring not only allows for a large clamping range to the shield but also enables easy and faster installation and re-installation. ■ 2-piece detachable sealing inserts can be adapted to the wider existing cable diameter on site. (AGE12 available only with 1-piece...
Open the catalog to page 5Remove the contact spring from the connector. Install the connector onto the enclosure. Clip the contact spring on the shielded cable. Pass the cable through the sealing insert and cap. AGE dimensions ■ DXF/DWG/PDF drawings available on our website.
Open the catalog to page 6Cable Gland Recommended Torque REFERENCE TABLE - AGE series The table below details the reference tightening torque values recommended for tightening of the cable gland. Excessive tightening may damage, or cause deformation to the cable, or to the cable gland itself. It is recommended to both utilize the table as a reference when tightening, as well as performing actual field testing to ascertain if the product/s are suitable to be used under the required conditions. Precautions should be taken when tightening to prevent damage and deformation of the components. When tightening, the connector...
Open the catalog to page 7HEAT RESISTANT METAL CABLE GLAND Heat Resistant ■ Heat resistant sealing insert made of FPM material. Resistant up to 200°C ■ IP68 1bar / 30min high performance waterproof cable gland. Technical Data Protection class : Protection class IP68 1bar / 30min 10m depth immersion in 30 minutes Operating temperature : -40°C ~ +200°C Compliant with EN50262 Var. A Conventional cable gland Thicker sealing insert evenly clasp onto the cable by having a larger area. Remains durable even after repeated tightening / loosening. If over-tightened, it can cause the rubber bush or cable to deform, which may allow...
Open the catalog to page 8AGH dimensions ■ DXF/DWG/PDF drawings available on our website. Product no. / Dimensions Cable range Mounting hole
Open the catalog to page 9Cable Gland Recommended Torque REFERENCE TABLE - AGH series The table below details the reference tightening torque values recommended for tightening of the cable gland. Excessive tightening may damage, or cause deformation to the cable, or to the cable gland itself. It is recommended to both utilize the table as a reference when tightening, as well as performing actual field testing to ascertain if the product/s are suitable to be used under the required conditions. Precautions should be taken when tightening to prevent damage and deformation of the components. When tightening, the connector...
Open the catalog to page 10series INTERCHANGEABLE HEAD TORQUE WRENCH ■ Torque wrench with interchangeable head. Suitable for the tightening of cable glands requiring a specific torque. Open end interchangeable head (spanner head) TWE series available separately. Spanner head is not included. Product no. Length Torque range (N • m) Increments (N • m) The torque wrench is not subject to RoHS regulations. Since it is an OEM product and not a JIS-compliant product, no calibration services or inspection reports, etc. are provided. When tightening, proceed first with a low value (half of the reference) of the recommended torque,...
Open the catalog to page 11Suitable TWE model RM • RMW series
Open the catalog to page 12Please read this manual carefully before use while following operation instructions. The manufacturer / retailer etc. will not be are not liable for any personal injuries, , damage to the product, or other property damage, etc. caused by improper use. * Do not use beyond the maximum torque value. This may cause damage and injury. * Do not use the torque wrench as a hammer or lever, or applying strong impact. * Do not modify or disassemble the torque wrench. These may cause strength or accuracy problems, which may lead to accidents and injuries. * Before use, check for damage, cracks, rust, or...
Open the catalog to page 13Handle center Torque scale 3⃣ How to use ① Push and hold the ring down to unlock. ・Turn the handle while the ring is in the unlock position. ③ Adjust to required torque. ・The ring will spring back to its original (lock) position. TAKACHI ELECTRONICS ENCLOSURE CO., LTD. TEL. +81-48-222-5409 https://www.takachi-enclosure.