TAKACHI ELECTRONICS ENCLOSURE CO., LTD. 3-21-16 Higashi-ryoke, Kawaguchi-shi, Saitama, 332-0003 JAPAN RM・RMW series - Changes to Cap design RM series: ALL (excluding RM50L-38□ & RM63L-44□) ■ Affected series / models : RMW series: ALL (excluding RM50L-38□) Black Light gray Light gray ■ Changes : Mold renewal and design change on the cap. ■ Purpose: To ensure consistent quality throughout via streamlined supply chain and materials. ■ Effective date : Once present inventory has run out / been depleted. ■ Note 1: No changes to material and color. ■ Note 2: No changes to item product number or pricing. Thank you for your understanding. For more information, kindly contact us at: sales
Open the catalog to page 1series POLYAMIDE CABLE GLAND ■ Low cost cable glands made from polyamide material. ■ Wide selection, for M8 ~ M63, suitable for 01mm ~ 044 mm cable. ■ High oil resistant NBR rubber sealing and O-ring. ■ Protection class equivalent to IP67. Technical Data Protection class : Equivalent to IP67* Operating temperature : -20°C ~ +80°C *In-house test RM dimensions ■ DXF/DWG/PDF drawings available on our website. Cap design varies by size L H SW ■ Lock nut is not included for RM8S-2.5, 8S-4, and 10S-6 models. Please drill an appropriate thread hole into the enclosure for installation. Product no. /...
Open the catalog to page 2■ Weatherproof cable gland equipped with high ultraviolet and degradation resistant silicone sealing insert and O-ring. ■ Recommended to use outdoors where waterproofing is critical. ■ Protection class equivalent to IP67. ■ DXF/DWG/PDF drawings available Please drill a proper thread hole into the enclosure for installation. Cap design varies by size RMW40 or smaller
Open the catalog to page 3RMW series silicone sealing insert weatherproof test report Object: Cut into a piece of the silicone sealing insert from RMW series and attach it onto an aluminium plate. For comparison, NBR sealing insert from our RM and EPDM sealing insert from another manufacturer is also attached. Testing conditions Equipment : Conditions : 7.5kW Super Xenon Weather Meter SX75 (Suga Test Instruments Co., Ltd.- http://www.sugatest.co.jp/english/) JIS B7754 : 1991 Testing with an authorized Xenon arc lamp weathering test equipment under the conditions denoted below. Irradiance : 180W/m2 at 300-400nm Black Panel...
Open the catalog to page 4RPG SERIES POLYAMIDE CABLE GLAND ■ Inexpensive cable glands made from polyamide material with PG threading. ■ High oil resistant NBR rubber sealing and O-ring. Technical Data ■ DXF/DWG/PDF drawings available on our website.
Open the catalog to page 5Accessories (Optional parts) ■ Sealing plug for cable glands when not in use. ■ Maintain a waterproof seal when plugged into the sealing insert on cable glands. Suitable cable glands
Open the catalog to page 6series INTERCHANGEABLE HEAD TORQUE WRENCH ■ Torque wrench with interchangeable head. Suitable for the tightening of cable glands requiring a specific torque. Open end interchangeable head (spanner head) TWE series available separately. Spanner head is not included. Product no. Length Torque range (N • m) Increments (N • m) The torque wrench is not subject to RoHS regulations. Since it is an OEM product and not a JIS-compliant product, no calibration services or inspection reports, etc. are provided. When tightening, proceed first with a low value (half of the reference) of the recommended torque,...
Open the catalog to page 7Suitable TWE model RM • RMW series
Open the catalog to page 8Please read this manual carefully before use while following operation instructions. The manufacturer / retailer etc. will not be are not liable for any personal injuries, , damage to the product, or other property damage, etc. caused by improper use. * Do not use beyond the maximum torque value. This may cause damage and injury. * Do not use the torque wrench as a hammer or lever, or applying strong impact. * Do not modify or disassemble the torque wrench. These may cause strength or accuracy problems, which may lead to accidents and injuries. * Before use, check for damage, cracks, rust, or...
Open the catalog to page 9Handle center Torque scale 3⃣ How to use ① Push and hold the ring down to unlock. ・Turn the handle while the ring is in the unlock position. ③ Adjust to required torque. ・The ring will spring back to its original (lock) position. TAKACHI ELECTRONICS ENCLOSURE CO., LTD. TEL. +81-48-222-5409 https://www.takachi-enclosure.