Overview: This document provides technical specifications, installation guidelines, and safety precautions for various series of cable glands and torque wrenches. It includes detailed product information, recommended usage conditions, and safety warnings.
Specifications:
  • REL Series Right Angled Cable Gland: Features L-shape cable glands with M type threads, allowing vertical wire routing. Offers IP67 equivalent protection and operates between -20°C to +80°C. Available in multiple sizes with specific cable range capacities.
  • RSP Series Strain Relief Cable Gland: Provides strain relief to prevent cable bending and breaking. Also offers IP67 equivalent protection. Includes a reference table for recommended tightening torque values.
  • TWH Series Interchangeable Head Torque Wrench: Designed for precise tightening of cable glands. Offers a torque range of 0.5 to 5.0 N•m with increments of 0.05 N•m. Various interchangeable heads available for different cable gland sizes.
Procedures:
  • Installation: Ensure proper torque application using the recommended values to avoid damage. Use tools to prevent co-rotation during tightening.
  • Operation of Torque Wrench: Set the torque before use, grip the handle center, and tighten slowly. Stop upon hearing or feeling a click to avoid overtorque.
Safety Precautions:
  • Do not exceed maximum torque values to prevent damage and injury.
  • Avoid using the torque wrench as a hammer or lever.
  • Inspect for damage before use and avoid using in high temperature or humid environments.
  • Wear safety glasses and ensure a secure grip to prevent accidents.
Recommendations:
  • Perform field testing to ensure suitability under specific conditions.
  • Store tools in a dry place and maintain cleanliness to ensure longevity.
See more

Catalog excerpts

REL series - RIGHT ANGLED CABLE GLAND-1

series RIGHT ANGLED CABLE GLAND ■ L-shape cable gland with M type threads.■ Allow wires to be routed vertically.■ Equivalent to IP67 protection class. Technical Data Protection class : Equivalent to IP67* Operating temperature : -20°C ~ +80°C *In-house test ■ DXF/DWG/PDF drawings available on our website. H Max SW

 Open the catalog to page 1
REL series - RIGHT ANGLED CABLE GLAND-2

RSP series STRAIN RELIEF CABLE GLAND ■ A total of 14 models available for selection. Protection class : Equivalent to IP67* Operating temperature : -20°C ~ +80°C ■ Strain relief cap protects cables by preventing it from bending beyond its limit and breaking.■ Economical price but high waterproofing capability equivalent to IP67. *In-house test ■ DXF/DWG/PDF drawings available on our website. ■ PA = Polyamide ComponentsProduct no. / Details Product no.

 Open the catalog to page 2
REL series - RIGHT ANGLED CABLE GLAND-3

Cable Gland Recommended Torque REFERENCE TABLE - RSP series The table below details the reference tightening torque values recommended for tightening of the cable gland. Excessive tightening may damage, or cause deformation to the cable, or to the cable gland itself. It is recommended to both utilize the table as a reference when tightening, as well as performing actual field testing to ascertain if the product/s are suitable to be used under the required conditions. Precautions should be taken when tightening to prevent damage and deformation of the components. When tightening, the connector...

 Open the catalog to page 3
REL series - RIGHT ANGLED CABLE GLAND-4

series INTERCHANGEABLE HEAD TORQUE WRENCH ■ Torque wrench with interchangeable head. Suitable for the tightening of cable glands requiring a specific torque. Open end interchangeable head (spanner head) TWE series available separately. Spanner head is not included. Product no. Length Torque range (N • m) Increments (N • m) The torque wrench is not subject to RoHS regulations. Since it is an OEM product and not a JIS-compliant product, no calibration services or inspection reports, etc. are provided. When tightening, proceed first with a low value (half of the reference) of the recommended torque,...

 Open the catalog to page 4
REL series - RIGHT ANGLED CABLE GLAND-5

Suitable TWE model RM • RMW series

 Open the catalog to page 5
REL series - RIGHT ANGLED CABLE GLAND-6

Please read this manual carefully before use while following operation instructions. The manufacturer / retailer etc. will not be are not liable for any personal injuries, , damage to the product, or other property damage, etc. caused by improper use. * Do not use beyond the maximum torque value. This may cause damage and injury. * Do not use the torque wrench as a hammer or lever, or applying strong impact. * Do not modify or disassemble the torque wrench. These may cause strength or accuracy problems, which may lead to accidents and injuries. * Before use, check for damage, cracks, rust, or...

 Open the catalog to page 6
REL series - RIGHT ANGLED CABLE GLAND-7

Handle center Torque scale 3⃣ How to use ① Push and hold the ring down to unlock. ・Turn the handle while the ring is in the unlock position. ③ Adjust to required torque. ・The ring will spring back to its original (lock) position. TAKACHI ELECTRONICS ENCLOSURE CO., LTD. TEL. +81-48-222-5409 https://www.takachi-enclosure.

 Open the catalog to page 7

All TAKACHI Electronics Enclosure Co., Ltd. catalogs and technical brochures

*Prices are pre-tax. They exclude delivery charges and customs duties and do not include additional charges for installation or activation options. Prices are indicative only and may vary by country, with changes to the cost of raw materials and exchange rates.