11 notice_e-01 Notice for TAIYO YUDEN products@ Please read this notice before using the TAIYO YUDEN products. REMINDERS ¡ Product information in this catalog is as of October 2010. All of the contents specified herein are subject to change without notice due to technical improvements, etc. Therefore, please check for the latest information carefully before practical application or usage of the Products. Please note that Taiyo Yuden Co., Ltd. shall not be responsible for any defects in products or equipment incorporating such products, which are caused under the conditions other than those specified in this catalog or individual specification. ¡ Please contact Taiyo Yuden Co., Ltd. for further details of product specifications as the individual specification is available. ¡ Please conduct validation and verification of products in actual condition of mounting and operating environment before commercial shipment of the equipment. ¡ All electronic components or functional modules listed in this catalog are developed, designed and intended for use in general electronics equipment.(for AV, office automation, household, office supply, information service, telecommunications, (such as mobile phone or PC) etc.). Before incorporating the components or devices into any equipment in the field such as transportation,( automotive control, train control, ship control), transportation signal, disaster prevention, medical, public information network (telephone exchange, base station) etc. which may have direct influence to harm or injure a human body, please contact Taiyo Yuden Co., Ltd. for more detail in advance. Do not incorporate the products into any equipment in fields such as aerospace, aviation, nuclear control, submarine system, military, etc. where higher safety and reliability are especially required. In addition, even electronic components or functional modules that are used for the general electronic equipment, if the equipment or the electric circuit require high safety or reliability function or performances, a sufficient reliability evaluation check for safety shall be performed before commercial shipment and moreover, due consideration to install a protective circuit is strongly recommended at customer's design stage. ¡ The contents of this catalog are applicable to the products which are purchased from our sales offices or distributors (so called “TAIYO YUDEN’s official sales channel”). It is only applicable to the products purchased from any of TAIYO YUDEN’ s official sales channel. ¡ Please note that Taiyo Yuden Co., Ltd. shall have no responsibility for any controversies or disputes that may occur in connection with a third party's intellectual property rights and other related rights arising from your usage of products in this catalog. Taiyo Yuden Co., Ltd. grants no license for such rights. ¡ Caution for export Certain items in this catalog may require specific procedures for export according to “Foreign Exchange and Foreign Trade Control Law” of Japan, “U.S. Export Administration Regulations”, and other applicable regulations. Should you have any question or inquiry on this matter, please contact our sales staff.
Open the catalog to page 1126 11 ¡ FEATURES ¡ ORDERING CODE ¡ EXTERNAL DIMENSIONS/MINIMUM QUANTITY ¡ APPLICATIONS ¡ IMPEDANCE-FREQUENCY CHARACTERISTICS Measured by HP4291A Please contact TAIYO YUDEN for further information in regard to other characteristics. FL05RD / FL05R TYPE FL06BT TYPE ¡ OPERATING TEMP. filter01_e-01 – This catalog contains the typical specification only due to the limitation of space. When you consider the purchase of our products, please check our specification. For details of each product (characteristics graph, reliability information, precautions for use, and so on), see our Web site (http://www.ty-top.com/)...
Open the catalog to page 2FERRITE PRODUCTS 11 127 ¡ PART NUMBERS filter01_e-01 – This catalog contains the typical specification only due to the limitation of space. When you consider the purchase of our products, please check our specification. For details of each product (characteristics graph, reliability information, precautions for use, and so on), see our Web site (http://www.ty-top.com/) or CD catalogs. Ordering code EHS (Environmental Hazardous Substances) Inductance [ìH] Impedance kÙl (typical) DC Resistance kÙl (max) Rated current kAl (max) FL05RD 1R0E RoHS 1.0{1.0 |0.5 800 (at 400MHz) 0.08 0.5 FL05R 100A RoHS...
Open the catalog to page 3filter01_pack-P1 11 filter01_pack_e-01 ¡ PACKAGING – This catalog contains the typical specification only due to the limitation of space. When you consider the purchase of our products, please check our specification. For details of each product (characteristics graph, reliability information, precautions for use, and so on), see our Web site (http://www.ty-top.com/) or CD catalogs. FL05RD ‡@Minimum Quantity Type Minimum Quantity (pcs.) Bulk Tape & Reel Ammo FL05R 500 [[ FL05RD 400 2000 1500 FL06BT 250 [[ ‡ATaping dimensions Type Symbol Dimension FL05RD D1 9.0 max. (0.354 max.) H2 9.0 max. (0.354...
Open the catalog to page 4le0104fi01_reli-RP1 11 le0104fi01_reli_e-01 ¡ RELIABILITY DATA – This catalog contains the typical specification only due to the limitation of space. When you consider the purchase of our products, please check our specification. For details of each product (characteristics graph, reliability information, precautions for use, and so on), see our Web site (http://www.ty-top.com/) or CD catalogs. 1. Operating temperature Range LA Type CAL45 Type [25`{105Ž LHL FBA/FBR [25`{85Ž FL05 Type [25`{105Ž FL06BT Type yTest Method and Remarksz LAECAEFL : Including self-generated heat LHL : Including...
Open the catalog to page 5le0104fi01_reli_e-01 11 le0104fi01_reli-RP2 ¡ RELIABILITY DATA – This catalog contains the typical specification only due to the limitation of space. When you consider the purchase of our products, please check our specification. For details of each product (characteristics graph, reliability information, precautions for use, and so on), see our Web site (http://www.ty-top.com/) or CD catalogs. 11. Over current LA Type No emission of smoke no firing. CAL45 Type LHL There shall be no scorch or short of wire. LHLC08,LHLC10 : There shall be no firing. FBA/FBR FL05 Type FL06BT Type yTest Method...
Open the catalog to page 62 Pages
3 Pages
3 Pages
3 Pages
3 Pages
3 Pages
52 Pages
81 Pages
26 Pages
32 Pages
49 Pages
33 Pages
9 Pages
4 Pages
5 Pages
6 Pages
4 Pages
7 Pages
8 Pages
7 Pages
21 Pages
15 Pages
13 Pages
13 Pages
30 Pages
19 Pages
7 Pages
13 Pages
14 Pages
9 Pages
56 Pages
7 Pages
47 Pages
29 Pages
33 Pages
21 Pages
45 Pages
2 Pages
2 Pages
2 Pages
2 Pages
2 Pages
2 Pages
2 Pages
2 Pages
12 Pages
2 Pages
2 Pages
2 Pages
2 Pages
4 Pages