GC
1Pages

{{requestButtons}}

Catalog excerpts

GC - 1

MANIFOLD TYPE FILTER 35 MPa 1. Maximum operating pressure: 35 MPa Impulse test: 35 MPa x 107 times 2. Spec, for option ► Model Code Element Type 3. Manifold-mount type. 4. Please contact us for use of fluids other than mineral oil on O-rings and other parts. 5. Manifold surface finish should be Ra 1.6S( vvv) or better. 6. For mounting, please prepare and use hexagon socket cap bolt (strength 12.9). Size Ml 6x60 ■ Replacement of filter element for Model GC (1) Loosen the plug on the side of body to drain oil. (2) Remove head cover and pull upward element holding the grip on end plate of the element. (3) Check a new element, O-rings and backup rings and if they are damaged, replace with new ones. Set a new element, the plug and head cover. (4) Prior to operation start-up, loosen the cap bolt in the center of head cover to release air. Caution ■ Part List Inner Diameter Case Length Filtration Rating Option Code Coding Example F-GC-12Z-5-3C-REV Code 3C: /?3 ^ 200 ★ Not to be used with water glycol-based oil. 8C : /3S ^ 200 & Filter media used for water glycol-based oil 25C : /?25 ^ 200 differs from that for mineral oil. (Note) “CH” is for high differential pressure 21 MPa elements. Relief valve cannot be attached. When releasing air, do not over-loosen No.7 Air vent plug. Avoid No.8 Steel ball pop-out which may cause injury. When removing No.1 Cover, make sure No.11 Set screw is tighten. (Loose screw may damage No.3 Sell.) ■ O-ring and backup ring (All GC models) Fluid Type # For element replacement (Part No. with © in “O-ring and Backup ring”.) SP Fluid Type GC 12 Z “R”: Indicator is installed on the RIGHT side when viewed from inlet. “L”: Indicator is installed on the LEFT side when viewed from inlet. Coding example: SP-F-GC-12Z-H For overhaul SA Fluid Type GC 12 Z Code Coding example: SA-F-GC-12Z-UW ► Flow Rate Chart -• ISO VG32 • Viscosity: 32cSt(40°C) Code ■ Dimensions and Standard Flow Rates ^\^ymbol Model ^^Part No. Part Name'''\ * 1 For use of 5UW, 10UW and 20UW X-2 Backup ring is included for use of high differential pressure element only.

Open the catalog to page 1

All TAISEI KOGYO catalogs and technical brochures

  1. FP

    1 Pages

  2. TL

    1 Pages

  3. 4201

    1 Pages

  4. 3501/3502

    1 Pages

  5. 351/352

    1 Pages

  6. GM series

    1 Pages

  7. TM series

    1 Pages

  8. SC series

    1 Pages

  9. UH series

    1 Pages

  10. LN series

    1 Pages

  11. UM

    1 Pages

  12. UL

    1 Pages

  13. 351 352

    1 Pages

  14. TSF

    1 Pages

  15. ISH

    1 Pages

  16. VM

    2 Pages

  17. VN

    2 Pages

  18. SFR

    2 Pages

  19. SFG

    2 Pages

  20. SFN

    2 Pages

  21. LINE FILTER

    8 Pages