1. Catalogs
  2. TA Instruments
  3. HIGH PERFORMANCE TGA SYSTEMS
video corpo

HIGH PERFORMANCE TGA SYSTEMS

HIGH PERFORMANCE TGA SYSTEMS
1 / 26 PagesView full catalog

HIGH PERFORMANCE TGA SYSTEMS

Product catalog summary
Overview of Thermogravimetric Analyzers (TGA)
TA Instruments offers the Discovery line of Thermogravimetric Analyzers, including models TGA 55, TGA 550, and TGA 5500, designed for high performance, accuracy, and reliability in research applications.
Specifications and Features
  • TGA 5500: High performance with minimal signal drift, fast heating/cooling, and a 25-position autosampler.
  • TGA 55: Cost-effective with Tru-Mass™ Balance for sensitivity and accuracy.
  • TGA 550: Flexible with advanced features like Hi-Res™ TGA and MTGA™.
Tru-Mass™ Balance
Ensures high sensitivity and low drift for accurate weight measurements without baseline subtractions.
Furnace Technology
TGA 5500 features a patented IR furnace; TGA 55 and 550 use standard and optional EGA furnaces for efficient heat transfer.
Autosampler and Atmosphere Control
25-position autosampler compatible with various pans; Gas-Delivery Manifold for consistent atmosphere control.
Software and User Interface
TRIOS software offers comprehensive data analysis, real-time editing, and data sharing; touch screen interface for simplified operation.
Advanced Analysis Techniques
  • Modulated TGA™ (MTGA): Provides kinetic data and activation energy calculation.
  • Hi-Res™ TGA: Controls heating rate for better resolution of weight losses.
  • Evolved Gas Analysis (EGA): Qualitative investigation of gases using MS or FTIR.
Applications of TGA
Includes verification of thermal events, moisture content analysis, volatiles analysis, and compositional analysis of materials.
High Pressure TGA Systems
Discovery HP-TGA instruments feature magnetic suspension balance, high pressure/temperature capabilities, and compact design.
Specifications
HP-TGA features a ceramic tube with a platinum heating element, operating up to 1100°C and 80 bar, suitable for corrosive atmospheres.
Procedures
Measures weight changes under varying conditions, supports Curie-point calibration, and operates in toxic/corrosive/explosive atmospheres.
Software
TRIOS software provides control and analysis capabilities, real-time data analysis, and automated reporting.
Applications
Suitable for high-temperature corrosion studies, gasification, pyrolysis, and decomposition of materials like calcium oxalate and PVC.
Key Features
Includes touch screen interface, ergonomic design, real-time monitoring, and advanced analysis capabilities.
Conclusion
The Discovery HP-TGA offers flexibility and precision for thermogravimetric analysis under high-pressure conditions, essential for research and industrial applications.
See more

Catalog excerpts

HIGH PERFORMANCE TGA SYSTEMS-1

The WORLD’S FINEST line of THERMOGRAVIMETRIC ANALYZERS

 Open the catalog to page 1
HIGH PERFORMANCE TGA SYSTEMS-2

HIGH PERFORMANCE TGA SYSTEMS that deliver the Most Accuracy Highest Sensitivity Greatest Reliability

 Open the catalog to page 2
HIGH PERFORMANCE TGA SYSTEMS-3

Thermogravimetric Analysis xxxxxx TA Instruments invites you to experience the world’s finest line of Thermogravimetric Analyzers, the Discovery TGA 55, TGA 550, and TGA 5500. Discover the advanced engineering and attention to detail that provides enhancements in every aspect of TGA technology and a new level of user experience. From the most cost-effective and flexible TGA with industry-leading performance, to the most advanced TGA available, there is a Discovery TGA to meet your needs Ultimate performance with every option to meet the requirements of the most demanding applications The TGA...

 Open the catalog to page 3
HIGH PERFORMANCE TGA SYSTEMS-4

No one makes a MORE SENSITIVE and ACCURATE THERMOBALANCE At the core of every new Discovery TGA is the proprietary Tru-Mass™ Balance. The Tru-Mass Balance system is Thermally isolated for high sensitivity in every laboratory environment, delivers the highest Resolution to separate components of the most challenging TGA samples, and has Ultra-low drift (Tru-Mass) for weight accuracy. Unlike competitive designs, the Discovery TGA delivers optimum performance without requiring baseline subtractions and other post-test manipulation required by competitors. The result is an innovative TGA with unrivaled...

 Open the catalog to page 4
HIGH PERFORMANCE TGA SYSTEMS-5

WIDEST RANGE of HEATING & COOLING RATES IR Furnace EVERY furnace on EVERY system is designed and manufactured by TA specifically for high performance TGA measurements. From the economical high-performing wire wound and EGA furnaces to the patented IR furnace* with industry-leading heating rates, there is a TGA furnace to meet your needs. Wire Wound (Pt/Rh) Furnace The TGA 5500 is the only system offering patented infrared heating technology. Optional Evolved Gas Analysis (EGA) furnace for the TGA 55 and TGA 550. • Linear controlled heating rates of 0.1 to 500°C/min • Linear controlled heating...

 Open the catalog to page 5
HIGH PERFORMANCE TGA SYSTEMS-6

Atmosphere Control BEST SAMPLE–ATMOSPHERE INTERACTION All Discovery TGA models are designed with superior atmosphere control to meet the most demanding applications. Whether maintaining an inert atmosphere, switching to an oxidative purge, or maintaining a high vacuum, the Discovery TGA is up to the task. Atmosphere Control Features and Benefits: Reliable Automation The Discovery TGA features a 25-position autosampler designed to be the most rugged and reliable system ever developed. Autosampler Features and Benefits: • Compatible with all pan types and sizes for ultimate flexibility • Sealed...

 Open the catalog to page 6
HIGH PERFORMANCE TGA SYSTEMS-7

“APP” Style Touch Screen Touch Screen Features and Benefits: • Ergonomic design for easy viewing and operation • Packed with functionality to simplify operation and enhance user experience. The touch screen includes: • Start/stop runs • Test and instrument status • Real-time signals • Real-time plot • Active method viewing • Advance method segments • Autosampler calibration • Loading/unloading and taring pans • System information The app-style touch screen, powerful new TRIOS software and the robust, reliable autosampler with automated calibration and verification routines all work seamlessly...

 Open the catalog to page 7
HIGH PERFORMANCE TGA SYSTEMS-8

TRIOS Software Discover powerful TRIOS software that delivers exceptional user experience in a combined package for instrument control, data analysis, and reporting for thermal analysis and rheology. New features such as multiple calibration sets, real-time test method editing, The Most VERSATILE CONTROL and ANALYSIS SOFTWARE! and inter-laboratory data and test method sharing provide unmatched flexibility, while one-click analysis and custom reporting raise productivity to new levels. Complete Data Analysis Capabilities TRIOS Features: • Control multiple instruments with a single PC and software...

 Open the catalog to page 8
HIGH PERFORMANCE TGA SYSTEMS-9

Modulated TGA™ Separation of Overlapping Weight Losses in Polyurethane 120 the heating rate is controlled by the decomposition rate of the sample. The Discovery TGA 5500 and 550 Standard TGA @ 10 ˚C/min Hi-Res TGA @ 50 ˚C/min designs are ideal for these measurements, featuring rapid response furnaces for precise temperature control and sensitive thermobalances designed to quickly detect small weight changes. • Separation of broad and overlapping weight losses • Increased productivity with better resolution The figure above shows the Hi-Res TGA results for a polyurethane material by standard and...

 Open the catalog to page 9
HIGH PERFORMANCE TGA SYSTEMS-10

Evolved gas analysis involves the qualitative investigation of the evolved gas products from a TGA experiment.These products are generally the result of decomposition, but can also evolve from desorption, evaporation or chemical reactions. Evolved gas analysis is typically performed by interfacing a mass spectrometer (MS) or Fourier transform infrared spectrometer (FTIR) to the exit port of the TGA furnace. Through the use of a heated transfer line, the evolved gas stream is delivered to the MS or FTIR instrument, and the compositional analysis is performed in real TGA-FTIR: Phenolic Resin Decomposition...

 Open the catalog to page 10
HIGH PERFORMANCE TGA SYSTEMS-11

Discovery Mass Spectrometer (DMS) Parameter The Discovery MS is a benchtop quadrupole mass spectrometer, designed and optimized for evolved gas analysis. It features industry-standard technology configured for the efficient transfer and rapid detection of offgas from the TGA furnace. Parts per billion (ppb) sensitivity is ensured with our state-of-the-art quadrupole detection system, including a closed ion source, a triple mass filter, and a dual (Faraday and Secondary Electron Multiplier) detector system. This analyzer configuration is selected to optimize sensitivity and long-term stability...

 Open the catalog to page 11
HIGH PERFORMANCE TGA SYSTEMS-12

Blending Gas Delivery Module Discovery TGA The Blending Gas Delivery Module (Blending GDM) delivers flexibility in gas handling on the Discovery TGA 5500, TGA 550, and SDT 650. The Blending GDM is an external accessory with two gas inlet ports that, when connected to the reactive gas port on the TGA or SDT, gives the user a total of four gases to control. The software-controlled accessory allows for automated switching between the four gas ports as well as blending of binary mixtures of gases. The added blending capability allows for TGA experiments to be carried out in an atmosphere where the...

 Open the catalog to page 12

All TA Instruments catalogs and technical brochures

  1. DCR_series

    16  Pages

  2. RSDSC-DSC-ITC

    54  Pages

  3. Discovery SA

    17  Pages

  4. SDT

    28  Pages

  5. TGA

    26  Pages

  6. DILATOMETRY

    13  Pages

  7. TMA

    15  Pages

  8. RUBBER TESTING

    19  Pages

  9. DMA

    23  Pages

  10. IsoSORP®

    13  Pages

  11. BROCH-DSDT

    28  Pages

  12. VTI-SA+

    6  Pages

Archived catalogs

*Prices are pre-tax. They exclude delivery charges and customs duties and do not include additional charges for installation or activation options. Prices are indicative only and may vary by country, with changes to the cost of raw materials and exchange rates.