Product catalog summary
Overview of ElectroForce Cardiovascular Solutions
ElectroForce provides a wide array of cardiovascular testing instruments aimed at the research, development, and validation of medical devices such as stents, heart valves, and vascular grafts. These instruments are designed for reliability and durability, capable of simulating both physiological and hyperphysiological conditions to expedite device testing and approval processes.
ElectroForce Technology
The proprietary technology employs electromagnetic motors for high dynamic performance and precise control over displacements, forces, and pressures. It supports long-term testing with minimal wear and includes a 10-year motor warranty.
Pulsatile Fatigue Testing
The DuraPulse Stent/Graft Test (SGT) instrument applies accelerated pulsatile distentions to stented devices, adhering to international standards like ISO 25539-2. It features dual-sided pulse generation for symmetric loading and accommodates various device geometries and sizes.
Axial Multi-Specimen Fatigue Testing
The MSF16 instrument allows for the simultaneous testing of up to 16 specimens, providing high statistical confidence in fatigue studies. It offers precise control over test parameters and includes features like independent load cells and temperature-controlled baths.
Multi-Axial Peripheral Stent Fatigue Testing
The MAPS instrument simulates complex in vivo conditions experienced by peripheral arteries, combining pulsatile fatigue with tensile, bending, and torsion modes. It supports various configurations to replicate anatomical conditions.
Heart Valve Accelerated Wear Testing
The DuraPulse Heart Valve Test (HVT) instrument tests heart valves at high frequencies, accommodating different valve types and sizes. It features independent sample control and advanced pressure control algorithms.
Biomaterial Characterization
The Planar Biaxial Test Instrument characterizes the material properties of biomaterials and medical devices, offering independent motor control and a range of testing modes. It supports environmental testing conditions with temperature-controlled baths.
Accessories and Software
ElectroForce provides a range of accessories and software solutions to enhance testing capabilities, including interchangeable manifolds, digital video extensometers, and user-friendly interfaces for test setup and data acquisition.
Support Services
Comprehensive support services are available to ensure optimal performance and reliability of ElectroForce instruments, aiding in the development of life-saving cardiovascular technologies.
Specifications and Components
The document details the specifications of ElectroForce Cardiovascular Test Instruments, including dimensions and weight. It lists various components such as pulsatile test instruments, manifold sets, silicone tubes, optical micrometers, pressure control assemblies, and pressure sensors. Accessories include system status indicator lights, uninterruptible power supply, tension grips, compression platens, and more.
Control System
The WinTest® digital control system is highlighted for its intuitive user interface, closed-loop waveform control, and data acquisition capabilities. It offers powerful waveform generation tools, advanced controls, and calculated channels for real-time mathematical calculations.
Software Applications
The DuraPulse™ SGT and HVT Application Software provide adaptive control modes, real-time data acquisition, and unique set-up windows for each device. The Multi-Axial Peripheral Stent Application Software allows for easy definition of test conditions.
Advanced Features
WinTest TuneIQ® and DuraPulse PeakIQTM are advanced software tools that enhance test control and optimize test conditions. The High Accuracy Displacement Sensor (HADS) offers high resolution and accuracy for displacement measurements.
Customer Support
TA Instruments emphasizes its commitment to after-sales support with a large team of field technical and service professionals worldwide, ensuring exceptional service and customer loyalty.
See more

Catalog excerpts

ELECTROFORCE® CARDIOVASCULAR TEST INSTRUMENTS-1

ELECTROFORCE® CARDIOVASCULAR TEST INSTRUMENTS

 Open the catalog to page 1
ELECTROFORCE® CARDIOVASCULAR TEST INSTRUMENTS-2

Accelerating development of life-saving technologies ElectroForce® Cardiovascular Solutions 4 Axial Multi-Specimen Fatigue 14 Multi-Axial Peripheral Stent Fatigue 20 Heart Valve Accelerated Wear 22

 Open the catalog to page 2
ELECTROFORCE® CARDIOVASCULAR TEST INSTRUMENTS-3

Bare Metal Stents Drug-Eluting Stents Heart Valves Septal Closure Devices Vena Cava Filter Structures Characterizing the widest range of Cardiovascular Medical Devices Annuloplasty Devices Cardiac Leads Vascular Grafts Decellularized Tissue 2 dynamic Performance & proven Reliability over billions of cycles ElectroForce® Cardiovascular test instruments comprise the most comprehensive portfolio of testing solutions for endovascular and interventional cardiology medical devices. For over 25 years, our test instruments have been used for research, development, and validation of innovative cardiovascular...

 Open the catalog to page 3
ELECTROFORCE® CARDIOVASCULAR TEST INSTRUMENTS-4

ELECTROFORCE® CARDIOVASCULAR SOLUTIONS TABLETOP & FLOOR-STANDING INSTRUMENTS Planar Biaxial TestBench Instrument DuraPulse™ Heart Valve Test (HVT) Instrument MSF16 Multi-Specimen Fatigue Instrument 9400 Multi-Axial Peripheral Stent (MAPS) Test Instrument DuraPulse Stent/Graft Test (SGT) Instrument

 Open the catalog to page 4
ELECTROFORCE® CARDIOVASCULAR TEST INSTRUMENTS-5

Anisotropic behavior characterization of heart valve leaflet materials Multi-specimen fatigue of heart valve sub-structures TRUSTED for TESTING along the... ENTIRE DEVELOPMENT PATHWAY Accelerated radial fatigue of entire stented heart valve frame Accelerated wear testing of complete heart valve device

 Open the catalog to page 5
ELECTROFORCE® CARDIOVASCULAR TEST INSTRUMENTS-6

ELECTROFORCE® TECHNOLOGY Perform fatigue tests at the highest frequencies Proprietary electromagnetic motor delivers industry-leading dynamic performance Unmatched waveform control and repeatability Friction-free technology provides unmatched responsiveness enabling the precise control of displacements, forces, and pressures Replicate 10 years of device life in a matter of weeks! Reliability that won’t let you down ElectroForce® linear motors integrate a flexural suspension eliminating the need for rolling or sliding bearings that wear out during long-term tests The industry’s only 10-year motor...

 Open the catalog to page 6
ELECTROFORCE® CARDIOVASCULAR TEST INSTRUMENTS-7

The industry standard for pulsatile fatigue testing of stented devices PULSATILE FATIGUE TEST INSTRUMENTS DURAPULSE™ STENT/GRAFT TEST (SGT) INSTRUMENT DuraPulse™ stent/graft test (SGT) instruments integrate proprietary ElectroForce® linear motors to apply accelerated pulsatile distentions to stent and stented devices deployed in mock vessels. Meeting or exceeding testing requirements defined by international standards such Dynamic optical micrometer measures real-time mock vessel diameter changes as ISO 25539-2, ASTM F2477 and ASTM F3211, DuraPulse SGTs reduce device time-to-market while providing...

 Open the catalog to page 7
ELECTROFORCE® CARDIOVASCULAR TEST INSTRUMENTS-8

PULSATILE FATIGUE TEST INSTRUMENTS I DURAPULSE™ STENT/GRAFT TEST (SGT) INSTRUMENT 4-Tube Manifold Kit Interchangeable Manifold Design Increased Flexibility Reduced Capital Investment ElectroForce Cardiovascular Test Instruments 13

 Open the catalog to page 8
ELECTROFORCE® CARDIOVASCULAR TEST INSTRUMENTS-9

MULTI-SPECIMEN FATIGUE TEST INSTRUMENTS 3330 MSF16 INSTRUMENT TA Instrument’s MSF16 Multi-Specimen Fatigue Instrument is designed to accelerate fatigue studies for a variety of materials, subcomponents and complete devices. With the capability of simultaneously testing 16 specimens at up to 100 Hz, users can generate S/N curves faster The proven workhorse for multi-specimen axial fatigue and with higher statistical confidence levels than ever before. In this system, proven and refined technologies come together to quickly ElectroForce 3330 MSF16 Dynamic Performance Advantage and confidently deliver...

 Open the catalog to page 9
ELECTROFORCE® CARDIOVASCULAR TEST INSTRUMENTS-10

MULTI-SPECIMEN FATIGUE TEST INSTRUMENTS MULTI-STATION TESTBENCH INSTRUMENT ElectroForce® Multi-Station TestBench instruments combine up to four independently-controlled, compact load frames, controlled from a single computer. Each TestBench station can be operated in either force or displacement control, offering the flexibility needed to perform long-term testing on devices or tissues that require stress or strain test conditions. Unmatched versatility in a multi-sample testing configuration • Available in either 2-, 3-, or 4-station configurations with a single shared computer • Independent...

 Open the catalog to page 10
ELECTROFORCE® CARDIOVASCULAR TEST INSTRUMENTS-11

MULTI-AXIAL PERIPHERAL STENT TESTING 9400 MAPS INSTRUMENT The patented Multi-Axial Peripheral Stent (MAPS) test instrument is the only system available that simultaneously provides the complex loading conditions experienced by peripheral arteries arteries such as those required by ASTM F2942. Combining accelerated pulsatile fatigue with tensile, bending, and torsion modes of loading in a single test instrument, MAPS can be used to replicate the twisting and bending of the superficial femoral artery that results from motions during walking, running, or jumping. In a similar fashion, the test instrument...

 Open the catalog to page 11
ELECTROFORCE® CARDIOVASCULAR TEST INSTRUMENTS-12

HEART VALVE ACCELERATED WEAR TESTING DURAPULSE™ HEART VALVE TEST (HVT) INSTRUMENT Setting the standard for accelerated prosthetic heart valve testing according to ISO 5840 test protocols, the DuraPulse™ Heart Valve test (HVT) instrument is capable of testing surgical or transcatheter heart valves at frequencies greater than 30 Hz. Available in 2-, 4- or 6-station configurations, the DuraPulse HVT provides independent sample control, enabling the removal and inspection of a single device without High-frequency performance and pressure control previously unachievable in heart valve durability testing...

 Open the catalog to page 12
ELECTROFORCE® CARDIOVASCULAR TEST INSTRUMENTS-13

Perhaps the most versatile test instrument available, the ElectroForce® Planar Biaxial can be used to characterize the material properties of biomaterials and medical devices, such as pericardium or heart valve leaflets. Available in 2- and 4-motor configurations, this system can assess the anisotropic behavior of materials to support development of constitutive models, compare the mechanical properties of synthetic materials to biologic tissues, or perform fatigue tests. Superior control and dynamic performance to characterize anisotropic material behavior Unparalleled performance for biomaterial...