1. Catalogs
  2. Systemair
  3. Pressure Differential System

Pressure Differential System

Pressure Differential System
1 / 20 PagesView full catalog

Pressure Differential System

Product catalog summary
Overview
Pressure Differential Systems are vital for maintaining smoke-free escape routes in buildings. Systemair integrates safety with advanced ventilation technologies to enhance fire protection and evacuation efficiency.

Principle of Pressure Differential Systems
These systems facilitate safe evacuation and firefighting by combining EC motor technology with frequency converter control. This integration ensures efficient smoke extraction and overpressure, improving visibility and access during fires.

Functionality
The MUB-EC system by Systemair meets EN 12101-6 standards with fewer components, utilizing electronic control technology to eliminate pressure relief units, thus ensuring low energy consumption and high performance.

Benefits of Electronic Overpressure Systems
  • Facilitates faster evacuation through smoke-free stairways.
  • Enhances rescue operations with optimal air volume control.
  • Offers flexibility and security for emergency personnel.
  • Reduces construction and operating costs.
  • Allows architectural freedom without large air terminal devices.


Components
The system includes supply air fan units, control panels, and sensors, supporting real-time operational display and integration with smoke detectors and manual call points.

Multibox EC and Axial Fan AXC
These components maintain constant differential pressure in stairwells, adjusting fan speed to meet setpoint values and can be coupled with smoke extraction fans for enhanced performance.

Technical Specifications
Specifications for Multibox EC and Axial Fan AXC include power, airflow, temperature limits, and sound pressure levels, designed for efficiency, flexibility, and low noise.

Conclusion
Systemair's Pressure Differential Systems offer a comprehensive fire safety solution, combining advanced technology with practical design for effective smoke management and safe evacuation routes.
Specifications
Systemair products are constructed from seawater-resistant aluminum and galvanized steel, featuring IEC flange motors with Efficiency Class IE2 and stainless steel impellers. They are suitable for coastal applications, withstanding temperatures of 400°C for 120 minutes and 600°C for 120 minutes.

Technical Data
Key data includes:
  • Max temperature: 400°C/120 min, 600°C/120 min
  • IE2 high-efficiency motor
  • Max airflow: 6196 m³/h
  • Fan impeller speed: 1445-1430 1/min
  • Max air temperature for 120 min: 300°C
  • Sound pressure level at 3 m: 73 dB(A)
  • Weight: 100 kg
  • Insulation class: H
  • Enclosure class: IP 55

Components and Accessories
The induction thrust fan (IHS) is compact, suitable for horizontal installation, and features a galvanized steel casing and aerodynamic impeller. Accessories include switches, smoke detectors, and alarms for enhanced safety.

Functional Principle of IHS
The IHS fan creates an air curtain above entry doors, reducing airflow through open entrances and maintaining air speed in stairwells during emergencies.

Systemair Global Presence
Systemair operates globally with facilities in multiple countries, each specializing in different air handling and ventilation products.

Quality and Certification
Systemair is ISO 9001, ISO 14001, and ATEX certified, with modern R&D labs adhering to international standards like AMCA and ISO.

Green Ventilation
Systemair promotes energy-efficient products under the "Green Ventilation" label, focusing on energy economy and efficiency.
See more

Catalog excerpts

Pressure Differential System-1

Fans | Air Handling Units | Air Distribution Products | Fire Safety | Air Conditioning | Air Curtains and Heating Products | Tunnel Fans Pressure Differential Systems The solution for smoke-free escape and emergency routes

 Open the catalog to page 1
Pressure Differential System-2

Safety can be integrated in planning. With Systemair. Principle Pressure Differential Systems 4 Function 6 Multibox EC 8 Axial fan AXC 10 Roof fan DVV and DVG 12 Induction thrust fan IHS 14 Accessories 16 Systemair 18

 Open the catalog to page 2
Pressure Differential System-3

The overpressure ventilation technology was invented during the eighties as an appropriate element within fire protection concepts for skyscrapers. The manufacturer Systemair was instrumental in pushing the development of an important improvement: the electronic control for pressurisation ventilation fans. This system provides higher security for selfrescue and especially for the fire brigade.

 Open the catalog to page 3
Pressure Differential System-4

Principle Pressure Differential Systems Stairways Pressure Differential Systems Important for save live and for a fast fire fighting In the case of fire, it is not just for the people fleeing that smoke gases present the greatest threat. It also puts the rescue service personnel at risk and hinders their work. Therefore, electronically-controlled overpressure systems bring a new dimension to fire protection. With a simple switch, the fire services can switch the supply air fans to maximum power, limiting the need for mobile fans to be used, or even making them unnecessary. This means that electronic...

 Open the catalog to page 4
Pressure Differential System-5

Principle Pressure Differential Systems Ten benefits of electronic overpressure systems 1. Faster self rescue Fire escape stairways are recommended even if other arrangements are permitted for escape and rescue routes. People evacuation is faster through smoke-free stairways or stairways with less smoke – the panic risk can be reduced. 2. Faster rescue by others On electronic overpressure systems, the air supply of the fans can be switched to the maximum air volume by a firefighter‘s switch. This enables pushing back and leading smoke away, even at high fire temperatures. The pressure in the...

 Open the catalog to page 5
Pressure Differential System-6

Multibox EC Thanks to a special control system, we are able to realise a constant differential pressure in stairwells, using EC fans. The constantly-measured differential pressure is evaluated in the control system in real-time and compared with corresponding setpoint values. The speed of the EC fans is adjusted by the control system so that the setpoint values are adhered to in the stairwell. This prevents the forces required to open the doors from getting too high (max. 100 N). By selectively controlling the outflows in the individual storeys, e.g. windows, the necessary airspeed (at least...

 Open the catalog to page 6
Pressure Differential System-7

Axial fan with frequency control Thanks to a special control system, a constant differential pressure is realised in the stairwell using AXC fans. The constantly-measured differential pressure is evaluated in the control system in real-time and compared with corresponding setpoint values. The speed of the fans is adjusted by the control system so that the setpoint values are adhered to in the stairwell. This prevents the forces required to open the doors from getting too high (max. 100 N). By selectively controlling the outflows in the individual storeys, e.g. windows, the necessary airspeed...

 Open the catalog to page 7
Pressure Differential System-8

Multibox EC Casing The casing consists of an aluminium frame with fibreglass reinforced plastic corners of PA6. The double skin panels are manufactured from galvanized steel with 20 mm mineral wool insulation. Motor MUB-EC fans are driven by EC-external rotor motors. All motors are suitable for 50/60Hz. Impeller All models are equipped with impellers with backward curved blades, manufactured from aluminium. • High efficiency in all areas of the fan curve • Removable panels Speed control 100% speed control by a 0-10V signal. • Flexible air flow direction • Installation in any mounting position...

 Open the catalog to page 8
Pressure Differential System-9

Reference: doubleU City, Country: Düsseldorf, Germany Products: Pressure differential system with 4 x MUB 062 630 EC

 Open the catalog to page 9
Pressure Differential System-10

Axial fan AXC The adjustable pitch angle setting offers a wide performance and maximum flexibility to match precisely individual airflow requirements. The AXC axial fans have been performance tested in accordance with DIN ISO 5801, DIN 24163 and AMCA 210-99 on the Systemair fan test rig. Impeller The AXC die cast aerofoil aluminium impellers can be offered with full or fractional solidities, maximum efficiencies can be obtained. Different impeller/hub configurations allow high operating pressures. • AXC with aerofoil impeller, adjustable pitch angle for maximum efficiency • Die cast aluminium...

 Open the catalog to page 10
Pressure Differential System-11

City, Country: Frankfurt am Main, Germany Products: Pressure differential systems with 4 x AXC 630-6-2 (7,5 kW) medium axial fans and 1 x DVV 800D6/F600 IE2 roof fan. Bildquelle: MACINA/KSP Jürgen Engel Architekten/FREO Group

 Open the catalog to page 11
Pressure Differential System-12

Roof fan DVV and DVG Casing The casing is manufactured from seawater resistant aluminium. The base frame consist of galvanised steel. Motor Frequency converter controllable IEC flange motors which comply with Efficiency Class IE2. Impeller The impeller with backward-curved blades is manufactured from stainless steel. • Max. temperature 400°C/120 min, 600°C/120 min. Speed control For speed control use frequency inverter. • IE2 high efficiency motor inside • Suitable for coastal applications Please find more information in our online-catalogue at www.systemair.com. • Vertical exhaust • Low sound...

 Open the catalog to page 12
Pressure Differential System-14

Induction thrust fan IHS The IHS is an induction thrust fan in a compact casing with an integrated, direct driven high performance centrifugal fan. It can be supplied with on-off switch (optional) and is suitable for horizontal installation. Casing Casing manufactured from galvanised steel, for maximum protection against corrosion. Motor 3-phase motors according to IEC standards; protection class IP55. • Easy installation and maintenance • Reduces the required supply air volume • Supply and extract air shafts can be minimized which saves space an money Impeller Aerodynamic centrifugal impeller...

 Open the catalog to page 14

All Systemair catalogs and technical brochures

  1. TFC roof fans

    4  Pages

  2. F400 smoke

    6  Pages

  3. MUB Fans

    8  Pages

Archived catalogs

  1. DELTRI+

    8  Pages

  2. SYSAQUA R32

    7  Pages

  3. Topvex

    134  Pages

  4. Topvex range

    8  Pages

  5. MoJet

    6  Pages

  6. prioJet EC

    4  Pages

  7. Roof fan TFC

    4  Pages

  8. Jet Fan Systems

    34  Pages

  9. Roof Fans DVV

    8  Pages

  10. Axial fans

    48  Pages

  11. Chilled Beam

    4  Pages

  12. SAVE Brochure

    8  Pages

  13. EC-Fans

    24  Pages

  14. Roof Fans DVG

    12  Pages

  15. Box Fans 2013

    20  Pages

  16. MRT Catalogue

    28  Pages

  17. ATEX-Fans

    2  Pages

  18. Fan Catalogue

    403  Pages

  19. AXC-Box

    2  Pages

  20. KDRE/KDRD

    8  Pages

  21. Axial Fans

    40  Pages

  22. Iris Damper

    4  Pages

  23. Air Curtains

    6  Pages

*Prices are pre-tax. They exclude delivery charges and customs duties and do not include additional charges for installation or activation options. Prices are indicative only and may vary by country, with changes to the cost of raw materials and exchange rates.