Fans | Air Handling Units | Air Distribution Products | Fire Safety | Air Conditioning | Air Curtains and Heating Products | Tunnel Fans Pressure Differential Systems The solution for smoke-free escape and emergency routes
Open the catalog to page 1Safety can be integrated in planning. With Systemair. Principle Pressure Differential Systems 4 Function 6 Multibox EC 8 Axial fan AXC 10 Roof fan DVV and DVG 12 Induction thrust fan IHS 14 Accessories 16 Systemair 18
Open the catalog to page 2The overpressure ventilation technology was invented during the eighties as an appropriate element within fire protection concepts for skyscrapers. The manufacturer Systemair was instrumental in pushing the development of an important improvement: the electronic control for pressurisation ventilation fans. This system provides higher security for selfrescue and especially for the fire brigade.
Open the catalog to page 3Principle Pressure Differential Systems Stairways Pressure Differential Systems Important for save live and for a fast fire fighting In the case of fire, it is not just for the people fleeing that smoke gases present the greatest threat. It also puts the rescue service personnel at risk and hinders their work. Therefore, electronically-controlled overpressure systems bring a new dimension to fire protection. With a simple switch, the fire services can switch the supply air fans to maximum power, limiting the need for mobile fans to be used, or even making them unnecessary. This means that electronic...
Open the catalog to page 4Principle Pressure Differential Systems Ten benefits of electronic overpressure systems 1. Faster self rescue Fire escape stairways are recommended even if other arrangements are permitted for escape and rescue routes. People evacuation is faster through smoke-free stairways or stairways with less smoke – the panic risk can be reduced. 2. Faster rescue by others On electronic overpressure systems, the air supply of the fans can be switched to the maximum air volume by a firefighter‘s switch. This enables pushing back and leading smoke away, even at high fire temperatures. The pressure in the...
Open the catalog to page 5Multibox EC Thanks to a special control system, we are able to realise a constant differential pressure in stairwells, using EC fans. The constantly-measured differential pressure is evaluated in the control system in real-time and compared with corresponding setpoint values. The speed of the EC fans is adjusted by the control system so that the setpoint values are adhered to in the stairwell. This prevents the forces required to open the doors from getting too high (max. 100 N). By selectively controlling the outflows in the individual storeys, e.g. windows, the necessary airspeed (at least...
Open the catalog to page 6Axial fan with frequency control Thanks to a special control system, a constant differential pressure is realised in the stairwell using AXC fans. The constantly-measured differential pressure is evaluated in the control system in real-time and compared with corresponding setpoint values. The speed of the fans is adjusted by the control system so that the setpoint values are adhered to in the stairwell. This prevents the forces required to open the doors from getting too high (max. 100 N). By selectively controlling the outflows in the individual storeys, e.g. windows, the necessary airspeed...
Open the catalog to page 7Multibox EC Casing The casing consists of an aluminium frame with fibreglass reinforced plastic corners of PA6. The double skin panels are manufactured from galvanized steel with 20 mm mineral wool insulation. Motor MUB-EC fans are driven by EC-external rotor motors. All motors are suitable for 50/60Hz. Impeller All models are equipped with impellers with backward curved blades, manufactured from aluminium. • High efficiency in all areas of the fan curve • Removable panels Speed control 100% speed control by a 0-10V signal. • Flexible air flow direction • Installation in any mounting position...
Open the catalog to page 8Reference: doubleU City, Country: Düsseldorf, Germany Products: Pressure differential system with 4 x MUB 062 630 EC
Open the catalog to page 9Axial fan AXC The adjustable pitch angle setting offers a wide performance and maximum flexibility to match precisely individual airflow requirements. The AXC axial fans have been performance tested in accordance with DIN ISO 5801, DIN 24163 and AMCA 210-99 on the Systemair fan test rig. Impeller The AXC die cast aerofoil aluminium impellers can be offered with full or fractional solidities, maximum efficiencies can be obtained. Different impeller/hub configurations allow high operating pressures. • AXC with aerofoil impeller, adjustable pitch angle for maximum efficiency • Die cast aluminium...
Open the catalog to page 10City, Country: Frankfurt am Main, Germany Products: Pressure differential systems with 4 x AXC 630-6-2 (7,5 kW) medium axial fans and 1 x DVV 800D6/F600 IE2 roof fan. Bildquelle: MACINA/KSP Jürgen Engel Architekten/FREO Group
Open the catalog to page 11Roof fan DVV and DVG Casing The casing is manufactured from seawater resistant aluminium. The base frame consist of galvanised steel. Motor Frequency converter controllable IEC flange motors which comply with Efficiency Class IE2. Impeller The impeller with backward-curved blades is manufactured from stainless steel. • Max. temperature 400°C/120 min, 600°C/120 min. Speed control For speed control use frequency inverter. • IE2 high efficiency motor inside • Suitable for coastal applications Please find more information in our online-catalogue at www.systemair.com. • Vertical exhaust • Low sound...
Open the catalog to page 12Induction thrust fan IHS The IHS is an induction thrust fan in a compact casing with an integrated, direct driven high performance centrifugal fan. It can be supplied with on-off switch (optional) and is suitable for horizontal installation. Casing Casing manufactured from galvanised steel, for maximum protection against corrosion. Motor 3-phase motors according to IEC standards; protection class IP55. • Easy installation and maintenance • Reduces the required supply air volume • Supply and extract air shafts can be minimized which saves space an money Impeller Aerodynamic centrifugal impeller...
Open the catalog to page 148 Pages
7 Pages
134 Pages
8 Pages
6 Pages
8 Pages
4 Pages
4 Pages
9 Pages
4 Pages
8 Pages
12 Pages
34 Pages
584 Pages
4 Pages
464 Pages
32 Pages
4 Pages
6 Pages
64 Pages
6 Pages
4 Pages
48 Pages
4 Pages
4 Pages
132 Pages
12 Pages
16 Pages
8 Pages
8 Pages
6 Pages
6 Pages
6 Pages
24 Pages
4 Pages
6 Pages
6 Pages
12 Pages
12 Pages
12 Pages
176 Pages
20 Pages
64 Pages
28 Pages
12 Pages
8 Pages
2 Pages
104 Pages
138 Pages
403 Pages
2 Pages
12 Pages
20 Pages
4 Pages
20 Pages
12 Pages
8 Pages
6 Pages
40 Pages
82 Pages
4 Pages
6 Pages
4 Pages
12 Pages