Fire Safety Products www.systemair.com Fire and smoke dampers Smoke Extract fans
Open the catalog to page 1Fire and Smoke dampers PK-I Fire dampers Systemair Fire dampers are manufactured and certified to latest European Standards EN1366-2. With wide product range and sizes for 60, 90 and 120 minute resistance for round and 90 and 60 minute resistance for rectangular ducting. - Round fire damper PK-I-R are available in Sizes: Diam 100 mm to diam 1000 mm. - Square fire damper PK-I-S are available in Sizes: 200 x 200 mm to 1600 x 1000 mm PK-I fire damper units are designed to be imbedded into the fire partition walls. All units as standard are available with manual rearmament lever or Actuator...
Open the catalog to page 2PVM Partition fire dampers Partition fire dampers type PVM are designed for nonducted applications where two fire zones are adjacent to each other.. These fire dampers are as standard imbedded into the fire partition wall and they incorporate protection grill on each side of the unit. Available as standard with manual operated reset lever and fusible link system or actuator driven with electrothermal cut off switch. Partition Fire dampers are tested a in accordance to EN1634-1 and classified as per EN 13501-2 for 60, 90 or 120 minute resistance. Available in sizes from 200x220 to 600x820...
Open the catalog to page 3HA (F) Smoke Extract axial The Systemair HA (F) range of long cased smoke extract axial fans is available in sizes from 315 up to 1600 mm impeller diameter. The HA (F) axial fans have been performance tested in accordance with DIN ISO fan test rig. High temperature testing at Technical University Munich, Germany, Three years warranty make it a safe choice. Fully tailored impellers Fully welded steel impellers tailored to match precisely individual air flow and pressure requirements. axial fans The Systemair AXC (B) range of long cased smoke extract axial fans is available in sizes from 315...
Open the catalog to page 4Multi stage fans For higher pressure drops two stage fans are offered. Two fans in series increase the available static pressure drop. Jet fan systems for Car park ventilation AJR and AJB for safe daily ventilation and smoke extraction (300°C/2h) in accordance with EN 12101-3. Systemair jet fans AJR and AJB offer highest system performance at low installation and running costs. They are available in impeller diameter 315, 355 and 400 mm. The system provides day-by-day ventilation as well as smoke extraction. For straight airflow the silencers have integrated inlet cones and guide vanes. The...
Open the catalog to page 5Roof Fans DVV Roof Fans The DVV smoke exhaust fans are used in case of fire to extract smoke gases from rooms, and are also used for normal ventilation working conditions. All fans are with backward curved impellers with the motor out side of the air stream. Certified according to EN 12101-3 • Roof smoke exhaust fan • 400°C/120 min (F400) and 600°C/120 min (F600) • For air volumes of 2 800 to 52 500 m3/h • Octagonal casing in Aluminum with vertical outlet. KBT/KBR Smoke Extract Fans KBT with impeller manufactured from galvanised sheet steel with forwardcurved blades. KBR with impeller...
Open the catalog to page 6Application and building description Smoke Extraction using natural ventilation In small to medium size buildings, natural convection or better known as chimney effect is commonly used. Using natural ventilation, smoke dampers and trap doors are installed at dedicated ducts for smoke evacuation, such would be a simple and effective solution for smoke exhaust. In such installations smoke detectors and controllers would be used to command such system. However, once the building construction begins to be more complex such as in the number of habitants, proper positioning of the chimney and the...
Open the catalog to page 7All Systemair catalogs and technical brochures
-
DELTRI+
8 Pages
-
SYSAQUA R32
7 Pages
-
Topvex
134 Pages
-
Topvex range
8 Pages
-
MoJet
6 Pages
-
Jet Tunnel Fans
8 Pages
-
Jet Fan IV smart
4 Pages
-
prioJet EC
4 Pages
-
Metro and Tunnel Fans
9 Pages
-
Pressure Differential System
20 Pages
-
Energy-efficient Ventilation
4 Pages
-
Roof Fans DVV
8 Pages
-
Roof Fans DVG EC
12 Pages
-
Jet Fan Systems
34 Pages
-
Fan Catalogue 2016
584 Pages
-
Roof fan TFC
4 Pages
-
Fan Catalogue 2013
464 Pages
-
The sileo generation
32 Pages
-
Thermo fan MUB/T-S EC
4 Pages
-
Thermo Fan AxZent
6 Pages
-
Fans with EC motor E8261
64 Pages
-
Roof Fans TFSR/TFSK E8071
6 Pages
-
Roof fan DVN EC / DVNI EC
4 Pages
-
Axial fans
48 Pages
-
Chilled Beam
4 Pages
-
Cassette chilled beam
4 Pages
-
Systemair Catalog Edition V
132 Pages
-
Product Overview
12 Pages
-
ErP Guideline 2013
16 Pages
-
SAVE Brochure
8 Pages
-
Thermo Fan MUB/T
8 Pages
-
Circular Duct Fan prioAir
6 Pages
-
Axial Fans AW sileo EC
6 Pages
-
Frequency Inverter FRQ
6 Pages
-
EC-Fans
24 Pages
-
Energy-efficient Ventilatio
4 Pages
-
Roof Fans TFSK/TFSR
6 Pages
-
Roof Fans DVS/DHS sileo
6 Pages
-
Roof Fans DVG
12 Pages
-
Smoke & Heat Extract Fans KVB/F
12 Pages
-
Smoke Extract Fan MUB/F
12 Pages
-
Air Conditioning catalogue
176 Pages
-
MRT Catalogue
28 Pages
-
Box Fans 2013
20 Pages
-
Smoke extract fans
12 Pages
-
ATEX-Fans
2 Pages
-
Air Distribution Products Catalogue
104 Pages
-
Residential Ventilation
64 Pages
-
Air Handling Units
138 Pages
-
Fan Catalogue
403 Pages
-
AXC-Box
2 Pages
Archived catalogs
-
LG, LGW – a comfort device
4 Pages
-
Portier – the designers choic
12 Pages
-
VX,VR – Heat recovery units
20 Pages
-
Maxi Comfort 800
20 Pages
-
Fans with EC-motors
12 Pages
-
KDRE/KDRD
8 Pages
-
TFSK/TFSR roof fans
6 Pages
-
Axial Fans
40 Pages
-
DV catalogue 2009
82 Pages
-
Iris Damper
4 Pages
-
Air Curtains
6 Pages
-
TLP Supply-air unit
4 Pages
-
Systemair Free Cooling
12 Pages