Fire Safety Products EKI-R-E60S Circular Evacuation Dampers Fire resistance class E30S & E60S installed out of the wall or ceiling in an insulated or un-insulated duct Ordering Codes Operating conditions alternatively EKI-R-E60S- Dimensions Operation type NOTES: E = Integrity S = Smoke leakage These evacuation dampers are designed and certified to comply with ES performance standards. EKI-R-E60S evacuation dampers are intended to be installed out of the wall/ceiling into an insulated/un-insulated duct. Installation of these units is described in the Installation, Operation and Maintenance Manual PP87_ EKI-R-E60S_EN. As standard, all dampers are servo-driven and can be delivered with a thermo -electrical release device, with a supply and communication control unit. Functionality of the evacuation damper Evacuation dampers are equipped with a servo that opens the damper blade on demand by the Building Management System or based on a current interruption in the thermo-electric release device. IMPORTANT: Evacuation dampers must be installed, operated and maintained according to the Installation, Operation and Maintenance Manual (PP87_EKI-R-E60S_EN)! Dampers equipped with the servo with a thermoelectrical release device may be operated in a workplace with an ambient operating temperatures of -10 to 65°C. The active fire-proof sealing must not be exposed to direct contact with water. The maximum air flow speed is 12 m/s with pure air without mechanical or chemical contamination with a uniform flow, without condensation, ice coating or ice. The maximum allowable pressure difference is 1200 Pa. This device is not actuated until the ambient temperature reaches 65°C. In case of a need for adjustment to higher temperatures in the working place it is advisable to consult such requirements with the producer and to indicate these requirements in the purchase order accordingly. In terms of their construction, the dampers are designed for use with a horizontal or a vertical blade axis. Transportation & Storage Conditions It is necessary to transport the dampers by means of transport that provide a cover and secures the dampers on pallets. When handling the dampers during transport and storage, the dampers must be protected against damage and weather conditions. The damper blades must be in the “CLOSED” position. It is recommended to store these products in a closed, dry, area where the temperature falls within the range of -10°C to +50°C. Material Used and its Disposal The product contains steel, zinc, calcium silicate board, graphite fire-proof laminate, ceramic sealing, polyurethane foam and ethylene-propylene dry rubber. These are processed in compliance with local regulations. The product does not contain any dangerous materials.
Open the catalog to page 1Fire Safety Products DV9-ST; spring return servo-operated fire dampers (24 V) without electro-thermal fuse, with auxiliary switches and Belimo BKN230-24 supply and communication unit. The manufacturer provides a 24-month warranty period starting on the date of expedition. DV9-T-ST; spring return servo-operated fire dampers (24 V) with electro-thermal fuse, auxiliary switches and Belimo BKN230-24 supply and communication unit Appendix Any requirements deviating from the above-mentioned technical specifications and conditions shall be discussed in advance with the manufacturer. The...
Open the catalog to page 2Fire Safety Products Fig. 2: Circular Evacuation Damper PKI-R-E60S Circular evacuation dampers EKI-R-E60S are certified according to EN15650, tested in accordance with EN 1366-2 regulation and classified for out of the wall/ceiling in the duct in accordance with EN13501-3+AI:2009 regulation with direct field of application: Tab. 1: Main dimensions, blade overhangs and weight Technical parameters Durability test - 10 200 cycles without a change to the required attributes Testing pressure Safe position Possible installations Out of the wall/ceiling in the insulated/uninsulated duct,...
Open the catalog to page 3All Systemair catalogs and technical brochures
-
DELTRI+
8 Pages
-
SYSAQUA R32
7 Pages
-
Topvex
134 Pages
-
Topvex range
8 Pages
-
MoJet
6 Pages
-
Jet Tunnel Fans
8 Pages
-
Jet Fan IV smart
4 Pages
-
prioJet EC
4 Pages
-
Metro and Tunnel Fans
9 Pages
-
Pressure Differential System
20 Pages
-
Energy-efficient Ventilation
4 Pages
-
Roof Fans DVV
8 Pages
-
Roof Fans DVG EC
12 Pages
-
Jet Fan Systems
34 Pages
-
Fan Catalogue 2016
584 Pages
-
Roof fan TFC
4 Pages
-
Fan Catalogue 2013
464 Pages
-
The sileo generation
32 Pages
-
Thermo fan MUB/T-S EC
4 Pages
-
Thermo Fan AxZent
6 Pages
-
Fans with EC motor E8261
64 Pages
-
Roof Fans TFSR/TFSK E8071
6 Pages
-
Roof fan DVN EC / DVNI EC
4 Pages
-
Axial fans
48 Pages
-
Chilled Beam
4 Pages
-
Cassette chilled beam
4 Pages
-
Systemair Catalog Edition V
132 Pages
-
Product Overview
12 Pages
-
ErP Guideline 2013
16 Pages
-
SAVE Brochure
8 Pages
-
Thermo Fan MUB/T
8 Pages
-
Circular Duct Fan prioAir
6 Pages
-
Axial Fans AW sileo EC
6 Pages
-
Frequency Inverter FRQ
6 Pages
-
EC-Fans
24 Pages
-
Energy-efficient Ventilatio
4 Pages
-
Roof Fans TFSK/TFSR
6 Pages
-
Roof Fans DVS/DHS sileo
6 Pages
-
Roof Fans DVG
12 Pages
-
Smoke & Heat Extract Fans KVB/F
12 Pages
-
Smoke Extract Fan MUB/F
12 Pages
-
Air Conditioning catalogue
176 Pages
-
MRT Catalogue
28 Pages
-
Box Fans 2013
20 Pages
-
Smoke extract fans
12 Pages
-
Fire Safety Products
8 Pages
-
ATEX-Fans
2 Pages
-
Air Distribution Products Catalogue
104 Pages
-
Residential Ventilation
64 Pages
-
Air Handling Units
138 Pages
-
Fan Catalogue
403 Pages
-
AXC-Box
2 Pages
Archived catalogs
-
LG, LGW – a comfort device
4 Pages
-
Portier – the designers choic
12 Pages
-
VX,VR – Heat recovery units
20 Pages
-
Maxi Comfort 800
20 Pages
-
Fans with EC-motors
12 Pages
-
KDRE/KDRD
8 Pages
-
TFSK/TFSR roof fans
6 Pages
-
Axial Fans
40 Pages
-
DV catalogue 2009
82 Pages
-
Iris Damper
4 Pages
-
Air Curtains
6 Pages
-
TLP Supply-air unit
4 Pages
-
Systemair Free Cooling
12 Pages