EKI-R-E60S Circular Evacuation Dampers
1 /3Pages

EKI-R-E60S Circular Evacuation Dampers

EKI-R-E60S Circular Evacuation Dampers
1 /3Pages

Catalog excerpts

EKI-R-E60S Circular Evacuation Dampers-1

Fire Safety Products EKI-R-E60S Circular Evacuation Dampers Fire resistance class E30S & E60S installed out of the wall or ceiling in an insulated or un-insulated duct Ordering Codes Operating conditions alternatively EKI-R-E60S- Dimensions Operation type NOTES: E = Integrity S = Smoke leakage These evacuation dampers are designed and certified to comply with ES performance standards. EKI-R-E60S evacuation dampers are intended to be installed out of the wall/ceiling into an insulated/un-insulated duct. Installation of these units is described in the Installation, Operation and Maintenance Manual PP87_ EKI-R-E60S_EN. As standard, all dampers are servo-driven and can be delivered with a thermo -electrical release device, with a supply and communication control unit. Functionality of the evacuation damper Evacuation dampers are equipped with a servo that opens the damper blade on demand by the Building Management System or based on a current interruption in the thermo-electric release device. IMPORTANT: Evacuation dampers must be installed, operated and maintained according to the Installation, Operation and Maintenance Manual (PP87_EKI-R-E60S_EN)! Dampers equipped with the servo with a thermoelectrical release device may be operated in a workplace with an ambient operating temperatures of -10 to 65°C. The active fire-proof sealing must not be exposed to direct contact with water. The maximum air flow speed is 12 m/s with pure air without mechanical or chemical contamination with a uniform flow, without condensation, ice coating or ice. The maximum allowable pressure difference is 1200 Pa. This device is not actuated until the ambient temperature reaches 65°C. In case of a need for adjustment to higher temperatures in the working place it is advisable to consult such requirements with the producer and to indicate these requirements in the purchase order accordingly. In terms of their construction, the dampers are designed for use with a horizontal or a vertical blade axis. Transportation & Storage Conditions It is necessary to transport the dampers by means of transport that provide a cover and secures the dampers on pallets. When handling the dampers during transport and storage, the dampers must be protected against damage and weather conditions. The damper blades must be in the “CLOSED” position. It is recommended to store these products in a closed, dry, area where the temperature falls within the range of -10°C to +50°C. Material Used and its Disposal The product contains steel, zinc, calcium silicate board, graphite fire-proof laminate, ceramic sealing, polyurethane foam and ethylene-propylene dry rubber. These are processed in compliance with local regulations. The product does not contain any dangerous materials.

 Open the catalog to page 1
EKI-R-E60S Circular Evacuation Dampers-2

Fire Safety Products DV9-ST; spring return servo-operated fire dampers (24 V) without electro-thermal fuse, with auxiliary switches and Belimo BKN230-24 supply and communication unit. The manufacturer provides a 24-month warranty period starting on the date of expedition. DV9-T-ST; spring return servo-operated fire dampers (24 V) with electro-thermal fuse, auxiliary switches and Belimo BKN230-24 supply and communication unit Appendix Any requirements deviating from the above-mentioned technical specifications and conditions shall be discussed in advance with the manufacturer. The manufacturer...

 Open the catalog to page 2
EKI-R-E60S Circular Evacuation Dampers-3

Fire Safety Products Fig. 2: Circular Evacuation Damper PKI-R-E60S Circular evacuation dampers EKI-R-E60S are certified according to EN15650, tested in accordance with EN 1366-2 regulation and classified for out of the wall/ceiling in the duct in accordance with EN13501-3+AI:2009 regulation with direct field of application: Tab. 1: Main dimensions, blade overhangs and weight Technical parameters Durability test - 10 200 cycles without a change to the required attributes Testing pressure Safe position Possible installations Out of the wall/ceiling in the insulated/uninsulated duct, vertical/horizontal,...

 Open the catalog to page 3

All Systemair catalogs and technical brochures

  1. DELTRI+

    8  Pages

  2. SYSAQUA R32

    7  Pages

  3. Topvex

    134  Pages

  4. Topvex range

    8  Pages

  5. MoJet

    6  Pages

  6. prioJet EC

    4  Pages

  7. Roof Fans DVV

    8  Pages

  8. Jet Fan Systems

    34  Pages

  9. Roof fan TFC

    4  Pages

  10. Axial fans

    48  Pages

  11. Chilled Beam

    4  Pages

  12. SAVE Brochure

    8  Pages

  13. EC-Fans

    24  Pages

  14. Roof Fans DVG

    12  Pages

  15. Box Fans 2013

    20  Pages

  16. MRT Catalogue

    28  Pages

  17. ATEX-Fans

    2  Pages

  18. Fan Catalogue

    403  Pages

  19. AXC-Box

    2  Pages

*Prices are pre-tax. They exclude delivery charges and customs duties and do not include additional charges for installation or activation options. Prices are indicative only and may vary by country, with changes to the cost of raw materials and exchange rates.