Chilled Beam
4Pages

{{requestButtons}}

Catalog excerpts

Chilled Beam - 1

Cooling effects for Cirrus 120 - 300 Chilled Beam Pressure Drop (kPa) and water ow at 0,05 l/s Cooling capacity Water (W) at Tmean Unit size • Cirrus chilled beam for ushmounting in false ceilings • Adapted for standard 600 mm false ceilings module • Available with the following functions: heating, comfort, control, NCS (Nozzle Control System), RCS (Room Comfort Support). Nozzle setting Cirrus 120 - 300 Cirrus is chilled beam and integrates ventilation, cooling and heating. It covers a wide range of supply air and assures you the best room comfort. It is supported with a nozzle technology NCS (nozzle control system) that gives you the highest induction rate and exible air pattern. Together with RCS (room comfort support), it helps you to have a good indoor condition by directing the air so it will create low air velocities in the occupied zone. Cirrus is available in length of 120, 180, 240 and 300 mm and adapted to false ceilings with a module of 600 mm. Denitions Tmean (K): s the Temperature difference between mean water (cooling/heating in and out) and room air TR Cooling capacity Primary air (W) at TPr Temperature difference between room air TR and primary air TPr Temperature difference between water ow TWIN and return TWOUT Temperature difference between room air TR and primary air TPr Temperature difference between water ow TWIN and return TWOUT TSWIN (K): Temperature difference between ceiling room air Tt and inlet water TWIN Primary air pressure drop PW (kPa): Water pressure drop Room temperature Ceiling room temperature TWOUT (ºC): Water return temperature Primary air cooling capacity Water cooling capacity TWIN (ºC): Water inlet temperature Ptotal (W): Total cooling capacity PPr + PSW QW (l/h): Water volume ow rate Q(l/s): Primary air volume ow rate LW-dB(A): Sound power level 2

Open the catalog to page 1
Chilled Beam - 2

Heating effects for Cirrus 120 - 300 Primary airow l/s Sound power Cirrus Length Correction Koct, dB Octave band, middle frequency (Hz) Pressure drop in coil - 4 pipes system - Cooling Pressure drop in coil - 4 pipes system - Heating Pressure drop coil The average sound attenuation L of the cassette chilled beam Stratus from duct to room includes the end reetion of the connecting duct. Correction Koct, dB Octave band, middle frequency (Hz) Sound attenuation The correction Koct is the average in the area of application of the cassette chilled beam Stratus. The sound power levels for each...

Open the catalog to page 2
Chilled Beam - 3

Discription and product code Front spigot With the use of RCS, you avoid the risk of getting a draft in the occupied zone and with an unhealthy workplace. To arrange the vanes in a pattern when beams have a risk to collide, are easily done and doesn’t affect pressure drop or noise level. E 1/2” Pipe male connection NCS (Nozzle Control System) Air-flow direction With the possibility to select a range of nozzle position that suits your installation. You will be able to adjust to the desired supply airow by selecting Nozzle positions S (Small), M (Mid) and L (for higher capacities by combining...

Open the catalog to page 3
Chilled Beam - 4

Fans | Air Handling Units | Air Distribution Products | Fire Safety | Air Curtains and Heating Products | Tunnel Fans Systemair • Inhouse studio • 2011 Chilled Beam

Open the catalog to page 4

All Systemair catalogs and technical brochures

  1. DELTRI+

    8 Pages

  2. SYSAQUA R32

    7 Pages

  3. Topvex

    134 Pages

  4. Topvex range

    8 Pages

  5. MoJet

    6 Pages

  6. prioJet EC

    4 Pages

  7. Roof fan TFC

    4 Pages

  8. Axial fans

    48 Pages

  9. EC-Fans

    24 Pages

  10. Roof Fans DVG

    12 Pages

  11. MRT Catalogue

    28 Pages

  12. Box Fans 2013

    20 Pages

  13. ATEX-Fans

    2 Pages

  14. Fan Catalogue

    403 Pages

  15. AXC-Box

    2 Pages

Archived catalogs

  1. KDRE/KDRD

    8 Pages

  2. Axial Fans

    40 Pages

  3. Iris Damper

    4 Pages

  4. Air Curtains

    6 Pages