Electromagnet Type 36 OverviewThis document provides technical specifications for the Electromagnet Type 36, including models I36, C36, and CI36. Each model operates with a rated power supply of 12/24 V and features different power and force characteristics.
Specifications- Power Supply: 12/24 V for all models.
- Pull Coil Absorption at 20°C: I36: 48/25.3 A, C36: 60/30 A, CI36: 60/30 A.
- Pull Coil Power at 20°C: I36: 576/606 W, C36: 720/720 W, CI36: 720/720 W.
- Hold Coil Absorption at 20°C: C36 and CI36: 0.4/0.2 A.
- Hold Coil Power at 20°C: C36 and CI36: 4.8/4.8 W.
- Coil Insulation Class: H for all models.
- Working Stroke: 20 mm for all models.
- Protection Degree: IP 45 for all models.
- Total Weight: I36: 0.900 Kg, C36: 1.700 Kg, CI36: 3.200 Kg.
Performance Characteristics- Start Stroke Force Without Spring at 20°C: I36: 60 N, C36: 50 N, CI36: 50 N.
- Holding Force Without Spring at 20°C: I36: 210 N, C36: 250 N, CI36: 470 N.
- Spring Preload at Beginning of Working Stroke: I36: 5 N, C36: 22 N, CI36: 13 N.
- Spring Loading at End of Working Stroke: I36: 36 N, C36: 54 N, CI36: 140 N.
Dimensions- Model I36: E: 53 mm, F: 15 mm, G: 118 mm, H: M5, I: 15 mm.
- Model C36: E: 74.5 mm, G: 124.5 mm.
- Model CI36: E: 53 mm, F: 15 mm, G: 118 mm, H: M5, I: 15 mm.
Additional Features- Optional return spring and rear output IP40 available.
- Cable length approximately 300 mm.
- Wiring for Type I36 includes 2 wires, while Type CI36 includes 3 wires (Red: Pull Coil, Black: Common, White: Hold Coil).
NotesThe force values are based on a single work cycle at 20°C. Any variation in the data may affect other parameters. System Di Rosati reserves the right to modify dimensions and characteristics without prior notice.