Electromagnet Type CI OverviewThis document provides technical specifications for the Electromagnet Type CI, including optional features such as a return spring and rear output with IP40 protection. The document covers four models: CI45, CI60, CI80, and CI100.
Specifications- Rated Power Supply: All models operate at 12/24 V.
- Pull Coil Absorption at 20°C: Ranges from 15 A to 42.8 A depending on the model.
- Pull Coil Power at 20°C: Ranges from 360 W to 523 W.
- Hold Coil Absorption at 20°C: Ranges from 0.3 A to 0.7 A.
- Hold Coil Power at 20°C: Ranges from 7.2 W to 8.8 W.
- Coil Insulation Class: All models are Class H.
- Working Stroke: 45 mm for all models.
- Start Stroke Force Without Spring at 20°C: Ranges from 25 N to 150 N.
- Holding Force Without Spring at 20°C: Ranges from 210 N to 770 N.
- Spring Preload and Loading: Varies by model, with preload ranging from 5 N to 50 N and loading from 36 N to 230 N.
- Protection Degree: IP45 for all models.
- Total Weight: Ranges from 0.900 kg to 6.300 kg.
DimensionsThe document provides detailed dimensions for each model, including diameter, length, and mounting specifications.
Important Notes- The force values are based on a single work cycle at 20°C.
- Any variation in the specified data can affect other parameters.
- System Di Rosati reserves the right to modify dimensions and characteristics without notice.
ConnectionsThe document includes a schematic for coil connections, indicating common and pull coil connections.