1. Catalogs
  2. Systech Illinois
  3. MM500 Moisture analyser for corrosive gases

MM500 Moisture analyser for corrosive gases

MM500 Moisture analyser for corrosive gases

MM500 Moisture analyser for corrosive gases

Product catalog summary
Overview: The MM500 is an advanced moisture analyser designed for accurate and reliable trace moisture measurement in corrosive gases such as Chlorine and Hydrogen Chloride. It is suitable for both safe and hazardous area locations.
Key Features:
  • Autoranging capability from 0.01ppm to 1000ppm.
  • RS232/485 outputs for data communication.
  • Measurement units include ppmv, Dewpoint °C, and °F.
  • Sample system rated IP65/Nema 4 for environmental protection.
  • No calibration required, reducing maintenance efforts.
  • Inert gas purge and fault alarm for enhanced safety.
  • Constructed with corrosion-resistant materials.
Technical Specifications:
  • Measurement accuracy of ±5% of reading or 0.4 ppm(v).
  • Response time of 90% within 60 seconds.
  • Operating temperature range from 0–40°C (32–104°F).
  • Sample connections are 1/4 inch OD with a maximum pressure of 0.7 – 8.3 Barg.
  • Power requirements are 115/230 VAC, 50/60 Hz, selectable.
Models and Configurations:
  • MM513: Bench/Panel Mount, dimensions 190H x 237W x 410D (mm), weight 7.9kg.
  • MM533: Rack Mount 4U - 19 inch, houses 1 or 2 analysers, dimensions 178H x 484W x 410D (mm), weight 9.7kg (single unit).
  • MM523: IP66/NEMA 4X Wall Mount/Weatherproof, dimensions 404H x 328W x 180D (mm), weight 13.1kg.
Options:
  • Analogue outputs scalable to 0 - 10V, 0 - 100mV, and 4 - 20mA or 0 - 20mA, all isolated.
  • High/Low alarms with voltage-free changeover contacts rated 240V 3A.
  • 19” Rack Mount configuration available.
Company Information: Systech Illinois has over 30 years of experience in providing analysis solutions for various industries, with manufacturing plants in the UK and U.S. They offer a range of gas analysers, headspace analysers, and permeation analysers.
See more

Catalog excerpts

MM500 Moisture analyser for corrosive gases-1

MM500 Moisture analyser for corrosive gases Accurate and reliable, on-line trace moisture analyser for Chlorine, Hydrogen Chloride and other corrosive gases in safe or hazardous area locations This sample system works in conjunction with our range of MM500 analysers for moisture measurement in corrosive gases. • Autoranging from 0.01ppm to 1000ppm • RS232/485 outputs • ppmv, Dewpoint °C and °F units • Sample system IP65/Nema 4 Designed specifically for corrosive gases, the MM500 Sample System allows safe, accurate and reliable analysis of moisture in corrosive gas mixtures. The MM500 Moisture Analysers represent the latest advance in moisture analysis - designed to be customised to your application giving precise measurements while providing a simple, yet affordable analyser. All instruments in the range incorporate microprocessor control, with our high quality electrolytic moisture sensor, to bring flexibility to your process environment. • No calibration required • Inert gas purge • Fault alarm • Corrosion resistant materials throughout These analysers provide an absolute measurement, with accurate dependable results over a wide range from 0.01ppm to 1000ppm. Unit of measurement can be selected from ppmv or dew point (°C or °F). Sample wetted parts are made from corrosion resistant materials throughout. All non-wetted brackets and materials are stainless steel. Simply select the instrument configuration and sensor location and let the analyser do the rest.

 Open the catalog to page 1
MM500 Moisture analyser for corrosive gases-2

Rack Mount 4U - 19 inch Houses 1 or 2 analysers 178H x 484W x 410D (mm) 9.7kg (single unit) Technical Specifications Measurement Ranges Accuracy Autoranging from 0.01ppm to 1000ppm and equivalent in Dew Point Other ranges are available with limited accuracy, please consult factory ±5% of reading or 0.4 ppm(v) Response Time Selectable Units ppm(v) / Dew Point °C / Dew Point °F Display Type 5 digit high visibility LED Operating Conditions Sample and ambient temperature: 0–40°C (32–104°F) Sample Connections Maximum Sample Pressure 0.7 – 8.3 Barg Sample Flow Power Requirements Acceptable Gases Chlorine/HCI...

 Open the catalog to page 2
*Prices are pre-tax. They exclude delivery charges and customs duties and do not include additional charges for installation or activation options. Prices are indicative only and may vary by country, with changes to the cost of raw materials and exchange rates.