Special Features: The LPS250 Series power supply offers active power factor correction, remote sense and inhibit capabilities, power fail signals, single wire current sharing, built-in EMI filter, low output ripple, supervisory outputs of 5V and 12V, overvoltage and overload protection, thermal overload protection, and DC power good indicators. It operates at a 120 kHz switching frequency and has optional fan covers.
Electrical Specifications: The power supply provides 250 Watts of total power with an input voltage range of 85-264 VAC or 120-300 VDC and a frequency range of 47-440 Hz. It has an efficiency of 75% at full load and a power factor of 0.99. The inrush current is limited to 20 A max at a cold start of 25°C. Safety ground leakage current is less than 0.5 mA at 50/60 Hz, 264 VAC input.
Output Specifications: The maximum power output is 250 W with 30 CFM forced air. The adjustment range is 2:1 wide ratio. Supervisory outputs include 5 V at 100 mA and 12 V at 500 mA. The hold-up time is 20 ms at a 250 W load with 115 VAC nominal line. Overload protection includes short circuit protection on all outputs and case overload protection at 110-145% above peak rating. Overvoltage protection is set at 5.7 to 6.7 VDC for the 5 V output and 10% to 25% above nominal output for other models.
Logic Control: Power failure is indicated by a TTL logic signal that goes high 50-150 msec after the 5 V output and low at least 4 msec before loss of regulation. Remote on/off requires an external contact to inhibit outputs. DC OK signal goes high 50-150 msec after the output and low when there is a loss of regulation. Remote sense compensates for a 0.5 V lead drop minimum and operates without being connected.
Environmental Specifications: The operating temperature range is 0° to 50°C ambient, with a derate of 2.5% per degree from 50° to 70°C. It is designed to meet IEC 801, -2, -3, -4, -5, -6, Level 3 for electromagnetic susceptibility. Humidity is 5% to 95% non-condensing. Vibration is tested at 0.7 G peak from 5 Hz to 500 Hz. Storage temperature ranges from -40° to 85°C. The temperature coefficient is ±.04% per °C. MTBF is demonstrated at over 550,000 hours at full load and 25°C ambient conditions.
Safety and Compliance: The power supply complies with VDE 0805/EN60950, UL1950, CSA 22.2-234 Level 5, NEMKO EN 60950/EMKO-TUE, BABT EN60950/BS7002, and has a CB Certificate and report. It also carries the CE Mark (LVD).
Mechanical Specifications: Dimensions are provided in inches with a tolerance of ±.02”. The weight is 2.6 lb (1.19 kg). The warranty period is 1 year.
Ordering Information: The document provides contact details for Astec in America, Europe, and Asia, along with ordering information for different models and optional fan covers.
See more

Catalog excerpts

250 Watts LPS250 Series-1

Total Power: 250 Watts Input Voltage: 85-264 VAC 120-300 VDC # of Outputs: Single Electrical Specs Input Input range Frequency Inrush current Efficiency EMI filter 85-264 VAC; 120-300 VDC 47-440 Hz 20 A max., cold start @ 25°C 75% typical at full load FCC Class B conducted and radiated CISPR 22 Class B conducted and radiated EN55022 Class B conducted and radiated VDE 0878 PT3 Class B conducted and radiated 0.99 typical Power factor Safety ground leakage current Special Features • • • • • • • • • • • • • • • • Output Maximum power Active power factor correction IEC EN6100-3-2 compliance Remote sense & remote inhibit Power fail Single wire current sharing Built-in EMI filter Low output ripple 2 Supervisory outputs 5 V and 12 V Overvoltage protection Overload protection Thermal overload protection DC power good Cover -C 120 kHz switching frequency Optional top with fan cover -CF Optional end fan cover -CEF Adjustment range Supervisory output Hold-up time Overload protection Overvoltage protection With cover: 250 W with 30 CFM forced air. (-C) (-CF) (CEF) 2:1 wide ratio 5 V @ 100 mA regulated; 12V @ 500 mA 20 ms @ 250 W load, 115 VAC nominal line at factory voltage setting Short circuit protection on all outputs. Case overload protected @ 110-145% above peak rating 5 V output: 5.7 to 6.7 VDC. Other models 10% to 25% above nominal output Logic Control Power failure Remote on/off Operating temperature: 0° to 50°C ambient derate each output at 2.5% per degree from 50° to 70°C Electromagnetic susceptibility: Designed to meet IEC 801, -2, -3, -4, -5, -6, Level 3 Remote sense Humidity: Operating; non-condensing 5% to 95% TTL logic signal goes high 50-150 msec after 5 V output. It goes low at least 4 msec before loss of regulation Requires an external contact (N.O or N.C) to inhibit outputs TTL logic goes high 50-150 msec after the output. It goes low when there is loss of regulation. Compensates for 0.5 V lead drop min. Will operate without remote sense connected. Reverse connection protected. Vibration: Three orthogonal axes, sweep at 1 oct/min, 5 min. dwell at four major resonances 0.7 G peak 5 Hz to 500 Hz, operational Storage temperature: -40° to 85°C Temperature coefficient: ±.04% per °C MTBF demonstrated: >550,000 hours at full load and 25°C ambient conditionsation

 Open the catalog to page 1
250 Watts LPS250 Series-2

5810 Van Allen Way Carlsbad, CA 92008 Telephone: 760-930-4600 Facsimile: 760-930-0698 Astec House, Waterfront Business Park Merry Hill, Dudley West Midlands, DY5 1LX, UK Telephone: 44 (1384) 842-211 Facsimile: 44 (1384) 843-355 Units 2111-2116, Level 21 Tower1, Metroplaza 223, Hing Fong Road Fwai Fong, New Territories Hong Kong Telephone: 852-2437-9662 Facsimile: 852-2402-4426 Ordering Information Model Number Output Voltage Minimum Load Maximum Load with 30 CFM Forced Air 1. Peak current lasting <30 seconds with a maximum 10% duty cycle. 2. At 25°C including initial tolerance, line voltage,...

 Open the catalog to page 2

Archived catalogs

  1. Power Wizard

    2  Pages

  2. Fenix Flyer

    2  Pages

*Prices are pre-tax. They exclude delivery charges and customs duties and do not include additional charges for installation or activation options. Prices are indicative only and may vary by country, with changes to the cost of raw materials and exchange rates.