Vmux Quick Startup Connecting an instrument • 1) Connect the instrument via cable 2) Wait for a few seconds 3) The channel will go green once a connection has been established The connection is automatically established on the next available channel at the next available output port • Bluetooth® Smart 1) Click on the «BT scan» button 2) Activate Bluetooth® on the instrument (menu BT/ON). If the instrument has already been connected to another master, don’t forget to reset pairing (menu BT/RESET). 3) Wait for connection and activation of services 4) The channel will go green once a connection has been established. A connection (USB or Bluetooth®) is automatically established on the next available channel at the next available output port. To connect the Sylvac S_FootSwitch Bluetooth®, press the main switch to activate Bluetooth® and follow steps 1)/3)/4). The S_FootSwitch Bluetooth® is not linked to an output port as instruments do. 1) Disconnect the instrument’s cable or click the cross corresponding to the channel to which the instrument is connected Bluetooth® Smart 1) Deactivate Bluetooth® on the instrument (menu BT/OFF) or click the cross corresponding to the channel on which the instrument is connected , this will erase the pairing if instrument is connected (green cross). The «Reset Config» button can also be used to disconnect all connected instruments (erase the Bluetooth® pairing for connected instruments) Reinitialising configuration (disconnecting all instruments) 1) Click on the «Reset Config» button; a confirmation message will appear 2) Confirm your selection to start reinitialisation 3) Reinitialisation will be comple

Open the catalog to page 1
Vmux - 2

Experts in connected metrology ! Changing an output port 1) Click on the output port (Output COM) to be changed; a dropdown list will appear 2) Select the desired output port 3) The change will be applied after a few seconds Redirecting all output ports to the same port 1) Click on the port redirection option 2) Select the desired output port; a warning message will appear 3) Confirm your choice to start redirection 4) Redirection will be applied after a few seconds Changing a channel 1) Click on the channel (Channel) to be changed; a drop-down list will appear 2) Select the desired channel...

Open the catalog to page 2
Vmux - 3

Experts in connected metrology ! Changing active channel Change active channel by clicking on channel’s box number. Alternatively, you can enable “Activate channel auto selection” option at the bottom right of the Settings view: channel selection will switch automatically to the instrument which value changes rapidly of more than 1mm. You can also change active channel by sending command “CHAx[cr]” or “ADNx[cr]” (where x is the channel number and [cr] is the carriage return character) to the output port. General settings You can change your global settings by pressing the Options button,...

Open the catalog to page 3
Vmux - 4

Experts in connected metrology ! Sending data request Perform a data request by sending command “?[cr]” (where [cr] is the carriage return character) to the output port. It will send a data request to all instruments connected to this output port, or only to the instrument connected on the active channel. You can edit these parameters in the export menu. You can send a data request to a specific channel by sending command “CHAx?[cr]” (where x is the channel number and [cr] is the carriage return character) to the output port. Sending special commands Send any Sylvac command (with [cr]as end...

Open the catalog to page 4
Vmux - 5

Experts in connected metrology ! In case of “Sequence action”, you can program a sequence of several actions : You can define any number of actions. Each will have a start trigger and a delay, if trigger is “None”, the actions will be executed consecutively. No timer available. A timer is available for the sequence. There is one trigger to start the timer and stop it. The define delay is the time between the execution of each actions. Exporting data 1) Go to “Options”, export tab. 2) Select an existing file (Excel, Word, Notepad, etc.) using the «Browse» button 3) Confirm your choice using...

Open the catalog to page 5
Vmux - 6

Experts in connected metrology ! On start-up • Vmux will start up with the last existing configuration • Bluetooth® instruments reconnect automatically if they are part of the last configuration (caution: the Bluetooth® sign must be blinking on the instrument’s display [BT command=ON] in order to detect the device). 32 available channels (max. 32 USB or max. 16 Bluetooth® and max. 16 USB) A maximum of 2 «Bluetooth® Smart» dongles 8 Bluetooth® devices by dongle Instruments can also be connected by USB cable Application is compatible with Windows XP, Windows 7, Windows 8 and Windows 10...

Open the catalog to page 6

All SYLVAC catalogs and technical brochures

  1. Applications

    1 Pages

  2. Catalogo e9.1

    277 Pages

  3. e8

    20 Pages

  4. Flyer UL4

    2 Pages

  5. Flyer D400S

    2 Pages

  6. Sylvac 2014

    219 Pages