SWAN Analytische Instrumente AG CH-8340 Hinwil/Switzerland Tel. +41 44 943 63 00 swan@swan.ch . www.swan.ch Monitor AMI pH/Redox Data sheet No. DenA2121X010 Monitor for continuous measurement of pH or redox (ORP) in high purity water, steam and condensate. 280 Monitor AMI pH/Redox QV-Flow Complete system mounted on stainless steel panel: Transmitter AMI pH/Redox in a rugged aluminum enclosure (IP 66). EXI T Various combined or separated sensors with reference electrodes available. Flow cell QV-Flow IS1000 made of stainless steel with quick release vessel, needle valve, digital sample flow meter and temperature sensor. Factory tested, ready for installation and operation. Specifications: Measuring range: 1 to 13 pH respectively -500 to +1500 mV depending on installed sensor. Simultaneous measurement of pH or redox, sample temperature and sample flow. Big backlit LC display for the reading of measuring value, sample temperature, sample flow and operating status. Easy user menus with simple programming of all parameters by keypad. Two current outputs (0/4 - 20 mA) for measured signals (3rd output optional). Monitor AMI pH/Redox QV-Flow DC Option: Monitor AMI pH/Redox QV-Flow AC [ ] HART interface [ ] Swansensor pH Standard (requires Adapter A-83.910.120) [ ] Swansensor pH FL (requires SS Reference FL) [ ] Swansensor ORP Standard (requires Adapter A-83.910.120) [ ] Swansensor ORP FL (requires SS Reference FL) Option: [ ] 3 current signal output (0/4 – 20mA) [ ] Profibus DP & Modbus RTU interface (RS-485) [ ] Swansensor Reference FL (requires cable A-88.121.120 ) 06/2020 Subject to change without notice
Open the catalog to page 1SWAN Analytische Instrumente AG CH-8340 Hinwil/Switzerland Tel. +41 44 943 63 00 swan@swan.ch . www.swan.ch pH/ORP Measurement Monitor AMI pH/Redox Data sheet No. DenA2121X010 Electrical Connection Scheme Signal input galvanically separated Input resistance: > 1013 pH measurement Measuring range with: -Swansensor ST/AY: -Swansensor SI/FL: Resolution: Reference temperature: ORP measurement Measuring range with: -Swansensor ST/AY: -400 to 1200 mV -Swansensor SI/FL: -500 to 1500 mV Resolution: 1 mV Temperature compensations automatic, according to: - Nernst (for potable water and wastewater)...
Open the catalog to page 2All Swan Analytical Instruments catalogs and technical brochures
-
AMI ISE Universal
2 Pages
-
AMI Hydrazine
2 Pages
-
AMI Codes-II TC
2 Pages
-
AMI Codes-II
2 Pages
-
AMI CACE
2 Pages
-
An Introduction for Non-Chemists
19 Pages
-
Pautbac II
2 Pages
-
Opal
2 Pages
-
TOC Evolution VUV
2 Pages
-
Topaz Analyzer
2 Pages
-
Automated Quality Assurance
6 Pages
-
Seven Sins of Steam Sampling
16 Pages