Group: SWAN Systeme / Seres OL
Catalog excerpts
SWAN Analytische Instrumente AG CH-8340 Hinwil/Switzerland Tel. +41 44 943 63 00 swan@swan.ch . www.swan.ch Monitor AMI Codes-II TC Data sheet no. DenA2544X6000 Complete monitoring system for the automatic, continuous measurement of total chlorine in potable water, sanitary water, cooling water and effluent. Monitor AMI Codes-II TC For the continuous online determination of disinfectants based on the DPD colorimetric method (EN ISO 7393-2; APHA 4500-Cl G). Measurement values : total chlorine 1, total chlorine 2, calculated dichloramine, flow and if installed pH and temperature. Complete system including measurement and control electronics, photometer, flow indicator, reaction chamber, reagent dosing system and reagent containers. Integrated pH measurement with temperature compensation (available as option). All usual dosing devices for disinfectants and pH control can be connected either through relays or analog output signals. Two independent controllers can operate simultaneously. Dosing of disinfectant can be interrupted automatically with an external signal, e.g. during sample flow interruption or filter backwashing. Two (optionally three) selectable measurement values are available as analog output signals. Alarm display and activation of alarm relay when user defined, critical limits for a measurement value are reached. Continuous, automatic monitoring of main instrument functions (dirty photometer, sample flow, reagents). Large back-lit LCD display showing all measured values and status information simultaneously. Factory tested, ready for installation and operation. Options: Communication interface pH option containing pH sensor, temperature sensor, cables and electronics board. Accessory: Chemical cleaning module. For details please see separate data sheet no. DenA82312000. Monitor AMI Codes-II TC DC Option: [ ] 3 current signal output (0/4 – 20mA) [ ] Profibus DP & Modbus RTU interface (RS-485) Option: 06/2020 Subject to change without notice
Open the catalog to page 1SWAN Analytische Instrumente AG CH-8340 Hinwil/Switzerland Tel. +41 44 943 63 00 swan@swan.ch . www.swan.ch Disinfectant measurement Monitor AMI Codes-II TC Data sheet no. DenA2544X6000 Electrical Connection Scheme Total chlorine (tc1 & tc2) measurement Measuring range (Standard) Accuracy 0.00 - 1.00 ppm 0.01 ppm 1.00 - 3.00 ppm 0.06 ppm 3.00 - 5.00 ppm 0.2 ppm Measuring range (Extended) 0.0 – 10 ppm Measurement time tc1: Measurement time tc2: Cycle time: tc1: measurement 3-5 seconds after injection of DPD & KI tc2: measurement 2 minutes after injection of DPD & KI Dichloramine:...
Open the catalog to page 2All Swan Analytical Instruments catalogs and technical brochures
-
AMI ISE Universal
2 Pages
-
AMI Hydrazine
2 Pages
-
AMI Codes-II
2 Pages
-
AMI CACE
2 Pages
-
AMI pH/Redox
2 Pages
-
An Introduction for Non-Chemists
19 Pages
-
Pautbac II
2 Pages
-
Opal
2 Pages
-
TOC Evolution VUV
2 Pages
-
Topaz Analyzer
2 Pages
-
Automated Quality Assurance
6 Pages
-
Seven Sins of Steam Sampling
16 Pages