Please use the following table to assist in placing your order with our sales staff. Order No. Description Application To close the measuring sections in case the sensor unit is removed A695 0009 Thread adapter, G 1/2" internal Used to adapt S401 or S450 to a PT to PT 1/2" external, SUS303 thread ball valve A695 0008 Thread adapter, G 1/2" internal Used to adapt S401 or S450 to a NPT to NPT 1/2" external, SUS303 thread ball valve Wafer type flow conditioners, which is flanged between two flanges 5-8 times diameter upstream of the flow meter. Please specify nominal pipe diameter and pressure High...
Open the catalog to page 2Ordering Please use the following table to assist in placing your order with our sales staff. Sensor cable, 5 pole, AWG 24 (0.2 mm²), 50 m Used to connect sensors and devices to gateways, power supplies and PLCs Sensor cable, 5 pole, AWG 24 (0.2 mm²), 100 m Used to connect sensors and devices to gateways, power supplies and PLCs RS-485 cable, 4 pole twisted pairs, AWG 24 (0.2 mm²), 50 m Used to connect sensors and devices to Modbus Masters RS-485 cable, 4 pole twisted pairs, AWG 24 (0.2 mm²), 100 m Used to connect sensors and devices to Modbus Masters Power supply, DIN rail, Input 85 ... 264...
Open the catalog to page 3Ordering Please use the following table to assist in placing your order with our sales staff. Measuring chamber, 2 l/min @ 0.8 MPa(g), fast connector, without filter, max pressure 1.6 MPa(g), suitable for all SUTO dew point sensors For easy connection and disconnection to compressed air system through quick-disconnector Measuring chamber, 2 l/min @ 0.8 MPa(g), 6 mm hose quick connector, without filter, max. pressure 1.6 MPa(g), suitable for all SUTO dew point sensors For easy connection and disconnection to compressed air system through quick-disconnector By-pass-type chamber with 6 mm hose in...
Open the catalog to page 4Please use the following table to assist in placing your order with our sales staff. Order No. Description Application Picture Is used to check dew point sensors. The pot creates a constant relative humidity A554 0002 Test pot 11.3 % rH of 11.3 %. The resulting dew point is depending on the ambient temperature, at 25 °C it is equal to -6.3 °C input and 2 alarm outputs, Installations in dryers or similar 85 ... 265 VAC supply, equipment as dew point indicator C219 0055 M12 connector with RS-485 termination resistor, 120 Q Termination resistor for enhancing communication stability of RS-485 network...
Open the catalog to page 5Ordering Please use the following table to assist in placing your order with our sales staff. Modbus/RTU to HART converter Modbus/RTU to HART converter, DIN rail mountable, requires 24 VDC power supply (not included) Modbus/RTU to Modbus/TCP converter Modbus/RTU to Modbus/TCP converter, wall mountable, requires 24 VDC power supply (not included) International Edition (EN) - 25-1. © 2025 SUTO iTEC GmbH. www.suto-itec.com