Turbidiyu meter
7Pages

{{requestButtons}}

Catalog excerpts

Turbidiyu meter - 1

Turbidity meter Turbidity meter

Open the catalog to page 1
Turbidiyu meter - 2

Turbidity meter online turbidity / MLSS concentration analyzer is an intelligent online chemical analyzer, which is widely used for continuous monitoring of turbidity, MLSS concentration and temperature in such solutions as thermal power, chemical, fertilizer, metallurgical, environmental protection, pharmaceutical, biochemical solutions, food, and tap water. Remote transmission monitoring and recording of continuous monitoring data is realized through the transmitting output connection recorder, and the monitoring and recording can also be realized by connecting the RS485 interface which...

Open the catalog to page 2
Turbidiyu meter - 3

Turbidity meter Turbidity sensor Specification Detailed Information O-ring: Fluorine rubber Cable: PVC Waterproof grade Measuring range IP68/NEMA6P Turbidity:0.00 ~ 4000NTU/ MLSS concentration: 0.1 ~ 20000 mg/L, 0.1 ~ 45000 mg/L, 0.1 ~ 120000 mg/L Turbidity: Less than ±2% of the measured value or ±0.1NTU, Display accuracy whichever is larger / MLSS concentration: less than ±5% of the measured value (depending on the homogeneity of the MLSS) Pressure range Storage temperature Ambient temperature for measurement Calibration of sample, slope calibration Cable length 10m standard cable, can be...

Open the catalog to page 3
Turbidiyu meter - 4

Turbidity meter Using 2.8 inch 128*64 lattice screen Using isolated transmitting output, which has less interference Using isolated RS485 communication TUR/TLSS measurement, upper and lower limit control, transmitting output and RS485 communication can be made High and low alarm functions and retardation can be set The buzzer and LCD backlight switch on and off function Operation language selectable, English or Chinese Correction and calibration of are available Display Turbidity monitoring screen:

Open the catalog to page 4
Turbidiyu meter - 5

Turbidity meter Description The device is designed for use on site. A rugged housing protects the electronics and the electrical connections from corrosive environmental conditions . As an alternative, the device can also be installed in a control panel. PUT100 turbidity meter  High alarm:High alarm  Low alarm:Low alarm  ESC:Check related warning status on the “monitoring page” Return to previous level page in the up& down level page linked to “menu page”  Menu: Enter the MENU on the “monitoring page” Exit the MENU on the “menu page”  :“MOVE RIGHT” and “MOVE DOWN”

Open the catalog to page 5
Turbidiyu meter - 6

Turbidity meter Wiring diagram Identification of terminal  AGND: Turbidity / MLSS concentration electrode power supply negative  RS485-A: Turbidity / MLSS concentration electrode communication positive  RS485-B: Turbidity / MLSS concentration electrode communication negative HO: High alarm normally open relay HC: High alarm normally closed relay LO: Low alarm normally open relay LC: Low alarm normally closed relay

Open the catalog to page 6
Turbidiyu meter - 7

Turbidity meter Calibration The Turbidity/MLSS concentration sensor has been calibrated before delivered, and the self calibration can be carried out according to the following steps if required. The use of standard liquid is required for the calibration of the MLSS concentration, taking two-point calibration as an example:  Connect the sensor to the transmitter. Set up the related parameters (set the Turbidity/MLSS concentration factoras1 in the signal setting), enter the Turbidity/MLSS Concentration Calibration actual value measurement interface and clean the sensor. Put the probe into...

Open the catalog to page 7

All Supmea Automation catalogs and technical brochures