1. Catalogs
  2. Supmea Automation
  3. SUP-LUGB-A Vortex flow meter
video corpo

SUP-LUGB-A Vortex flow meter

SUP-LUGB-A Vortex flow meter

SUP-LUGB-A Vortex flow meter

Product catalog summary
Introduction
The LUGB-SUP-A Vortex Flow Meter is designed for measuring the flow of liquids, gases, and vapors, including turbid liquids with impurities. It is applicable in industries such as petroleum, chemical, paper making, metallurgy, electric force, environmental protection, and food.

Features
  • Low pressure loss, wide range, and high accuracy.
  • Unaffected by fluid density, pressure, temperature, and viscosity when measuring volume flow.
  • No moving parts, ensuring high reliability and low maintenance.
  • Operates in temperatures ranging from -40℃ to +400℃.
  • Supports both analog and digital outputs for integration with digital systems.

Principle of Operation
The flow meter operates on the principle of Karman vortex street, where a bluff body in the fluid generates alternating vortex columns. The frequency of these vortices is used to calculate the flow velocity and volume flow rate.

Specifications
  • Nominal Diameter: DN10-DN500
  • Pressure Ratings: Various, depending on connection type and size.
  • Medium Temperature: Ranges from -40°C to +420°C.
  • Material: Stainless steel
  • Accuracy: ±1%R to ±2.5%R depending on type.
  • Power Supply: 12VDC, 24VDC, or 3.6V Li battery
  • Output: Pulse and 4-20mA current
  • Communication: RS485, Modbus-RTU
  • Protection Grade: IP65, IP68

Instrument Flow Range
Flow ranges are specified under reference conditions for gas and liquid, with specific details for saturated steam.

Instrument Dimensions
Dimensions are provided for various pipe diameters, detailing height, width, and length specifications.

Operation Instructions
  • Interface and key functions are described for setting and navigating the menu.
  • Parameter settings require password verification.

Ordering Code
The ordering code section provides options for model configuration, including medium type, nominal pipe size, accuracy, display, output, communication, compensation type, installation, power supply, pressure rating, and temperature rating.
See more

Catalog excerpts

SUP-LUGB-A Vortex flow meter-1

E-mail: [email protected] Vortex Flow Meter Committed to process automation solutions Add: 5th floor, Building 4, Singapore-Hangzhou Science & Technology Park, Hangzhou,China

 Open the catalog to page 1
SUP-LUGB-A Vortex flow meter-2

E-mail: [email protected] SUP-LUGB Vortex flow meter is on the principle of Karman street, to measure liquid, gas and vapor even turbid liquid including micro grain and impurity. Applications: petroleum, chemical industry, paper making, metallurgy, electric force, environmental protection, food industry and etc. Features ·small pressure loss, wide range, high accuracy; ·It is hardly affected by fluid density, pressure, temperature and viscosity when measuring volume flow under working status; ·No moving mechanical parts, thus high reliability and low maintenance. Instrument parameters can be stable...

 Open the catalog to page 2
SUP-LUGB-A Vortex flow meter-3

E-mail: [email protected] the Strouhal number (st) is a dimensionless unknown. The figure below shows the relationship between Strouhal number (St) and Reynolds number (Re). In the curve table, the flat part of St = 0.17, the release frequency and velocity are proportional, that is the measuring range of vortex flow sensor. As long as the frequency f is detected, the flow velocity of fluid in the pipe can be obtained. Volume flow rate is determined by the velocity V. The ratio of measured pulse number and the volume is called meter constant (K), see Formula 2. Formula 2 :K = 3600 f/Q (1/m3) In...

 Open the catalog to page 3
SUP-LUGB-A Vortex flow meter-4

E-mail: [email protected] Product Introduction Nominal pressure wafer connection Main body material Accuracy Power Voltage Nominal pressure flange connection Medium temperature (℃) Output Communication Protection Grade Ambient conditions Pressure lose Applicable mediums Transmission distance Pulse: high level≥6V, low level≤1V; current: 4-20mA RS485, Modbus-RTU IP65, IP68 Temp. -20℃ to 60℃ , relative humidity 5% to 95%, atmospheric pressure 86 to 106 KPa △P≤1.2ρ V P² (△P unit is Pa, ρ unit is kg/m³ ,V unit is m/s) Gas, liquid and steam 3 wire pulse output:≤300m, 2 wire current output (4-20mA)≤1500m;...

 Open the catalog to page 4
SUP-LUGB-A Vortex flow meter-5

E-mail: [email protected] Instrument Flow Range 1. Reference conditions: Gas: air under normal temperature and normal pressure, t = 20 ℃ , P = 0.1 MPa (absolute pressure),ρ=1.205 kg/m3,ν= 15×10 m /s Liquid: water under normal temperature:t = 20℃,ρ= 998.2 kg/m3,ν= 1.006×10 m /s 2. LUGB Vortex flowmeter measure saturated steam of different density corresponding with flow range under working condition: Add: 5th floor, Building 4, Singapore-Hangzhou Science & Technology Park, Hangzho

 Open the catalog to page 5
SUP-LUGB-A Vortex flow meter-6

E-mail: [email protected] Instrument Dimensions Wafer version Flange version P&T compensation compact version Add: 5th floor, Building 4, Singapore-Hangzhou Science & Technology Park, Hangzhou,China

 Open the catalog to page 6
SUP-LUGB-A Vortex flow meter-7

E-mail: [email protected] Operation Instruction 1. Interface key (K1): Enter the setting status and confirm the setting value; key (K2): moves the cursor position to the next loop; key (K3): Add 1 or function selection to the value of the cursor; key (K4): Returns to the previous menu item. 3. Menu press key (K1) to enter the menu. Press (K2) to cycle through the menus and press (K1) to enter. 4. Parameter settings In the menu, press key (K1) to enter the password verification interface. After entering the correct password, you can set the parameters. Add: 5th floor, Building 4, Singapore-Hangzhou...

 Open the catalog to page 7
SUP-LUGB-A Vortex flow meter-8

E-mail: [email protected] Ordering code Vortex Flow Meter Model - Liquid Steam Nominal pipe size Without display Pulse output Communication output Temperature compensation Pressure compensation Compensation type Temp & pressure compensation I2 Flange installation Power supply Pressure rating Add: 5th floor, Building 4, Singapore-Hangzhou Science & Technology Park, Hangzho

 Open the catalog to page 8
SUP-LUGB-A Vortex flow meter-9

E-mail: [email protected] Add: 5th floor, Building 4, Singapore-Hangzhou Science & Technology Park, Hangzhou,China

 Open the catalog to page 9
*Prices are pre-tax. They exclude delivery charges and customs duties and do not include additional charges for installation or activation options. Prices are indicative only and may vary by country, with changes to the cost of raw materials and exchange rates.