Product catalog summary
Overview: The SUP-LDG electromagnetic flow meter by Supmea is designed for measuring the flow of electrically conductive fluids using electrodes to detect the magnetic field induced by fluid flow. This design minimizes mechanical wear and is suitable for various industrial applications.
Specifications: The flow meter requires a minimum fluid conductivity of 5μS/cm and is not suitable for non-conductive fluids like oil. It offers a measuring accuracy of 0.5% F.S, supports RS485 mod-bus communication, and provides a 4-20mA output. It can measure flow in both directions and is unaffected by changes in temperature, pressure, or fluid density.
Applications: Suitable for sewage treatment, chemical industry, environmental protection, metallurgy, medicine, papermaking, and water supply systems.
Features: Provides accurate readings without pressure loss and is unaffected by fluid viscosity. It cannot detect gases or non-conductive liquids.
Measurement Principle: Based on Faraday's law of electromagnetic induction, it generates an electromotive force proportional to the flow speed, detected by electrodes and processed to display flow data.
Installation and Operation: Should not be installed on vibrating pipes or the suction side of pumps. Requires grounding to prevent electromagnetic interference and supports various installation methods, including flange and clamp mounting.
Materials and Construction: Sensor housing is made of carbon steel, with options for stainless steel. Lining materials include neoprene, polyurethane, and Teflon. Electrode materials include stainless steel, titanium, and platinum.
Environmental and Operating Conditions: Operates in temperatures from -10℃ to 60℃, with storage temperatures from -40℃ to 65℃. Designed for environments with a minimum water conductivity of 20μS/cm.
Ordering Information: Customizable based on type, pipe size, accuracy, output, communication, installation method, power supply, pressure rating, temperature rating, electrode material, lining material, grounding, body material, and ingress protection.
See more

Catalog excerpts

SUP-LDG Flow meter-1

Datasheet electromagnetic flow meter SUP-LDG Committed to process automation solutions Tel: 86-15158063876 E-mail: [email protected] www.supmea.com F-

 Open the catalog to page 1
SUP-LDG Flow meter-2

Datasheet Electromagnetic flow meter for flow measurement SUP-LDG-DNXX flow meter Supmea's electromagnetic flow meter does not contain any moving parts, rotating gears or turbines, or bearings. Instead, it relies on two electrodes to measure the density of the induced magnetic field that results from an electrically conductive fluid, such as water, flowing through a pipe. So there is no susceptibility to bearing wear or other mechanical wear-and-tear issues. As for the electrodes and the liner used in electromagnetic flow meter, these components can be fabricated from a variety of materials to...

 Open the catalog to page 2
SUP-LDG Flow meter-3

Principle The measurement principle of magnetic flowmeters can be described as follows: when the liquid goes through the pipe at the flow rate of v with a diameter D, within which a magnetic flux density of B is created by an exciting coil, the following electromotive E is generated in proportion to flow speed v: E=K×B×V×D Where: E-Induced electromotive force K-Meter constant B-Magnetic induction density V-Average flow speed in cross-section of measuring tube D-Inner diameter of measuring tube The induced voltage signal is detected by two electrodes and transmitted to the converter via a cable....

 Open the catalog to page 3
SUP-LDG Flow meter-4

Type Remote type Remote type flowmeter signal converter 2 Remote type electromagnetic flowmeter sensor 3 Signal cable 4 User manual 1 Compact type Compact type 1 2 Compact type electromagnetic flowmeter User manual

 Open the catalog to page 4
SUP-LDG Flow meter-5

Parameter Power supply Power supply Power consumption Signal cable Apply only to remote type Shielded cable Output Current output function Measurement of volume and quality (in the case of constant density) Internal voltage Pulse and frequency output function Pulse output Set up Pulse and frequency output basis Output pulse width: 0.25ms ~100ms Duty cycle: 50% (Pulse frequency ≥5Hz) Fmax ≤ 5000 cp/s Status output function passive Output as alarm UOuter≤ 36VDC Communications Serial communications Current (4-20 mA) , pulse , frequency , state switch

 Open the catalog to page 5
SUP-LDG Flow meter-6

Measurement Accuracy Max measuring error Measurement value ±0.5%(Flow speed > 1m/s); Measurement value ±0.5% ±2mm/s(Flow speed <1m/s) Temperature sensor measuring range Maximum measurement error ±0.1℃(Within the measuring range of temperature sensor) Operating Environment Temperature Environment -10℃ - 55℃ for Compact-Type Flowmeter -10℃ - 60℃ for Converter of Remote-Type Flowmeter -10℃ – 55℃ for Converter of Remote-Type Flowmeter Electric Conductivity Water Other Min. 20μS/cm (Actual electric conductivity should be greater than 50μS/cm) Min. 5μS/cm (Actual electric conductivity should be greater...

 Open the catalog to page 6
SUP-LDG Flow meter-7

Converter Compact Type Remote Type Measurement sensor Nominal Diameter Flange Pressure rating (High pressure can be customized) DN15-DN1000 In line with GB/T9119-2000 standard carbon steel (Optional stainless steel flanges), other standard flange can be customized DN6 - DN80, PN<4.0MPa DN100 - DN150, PN<1.6MPa DN200 – DN1000, PN<1.0MPa Lining Material Electrode Material DN1200 – DN2000, PN<0.6MPa Chloroprene rubber (CR), Polytetrafluoroethylene (PTFE/F4), Fluorinated ethylene propylene (FEP/F46), Teflon(PFA) 316L Stainless Steel, Hastelloy C, Hastelloy B, Ti, Ta, Pt IP68 Medium temperature Buried...

 Open the catalog to page 7
SUP-LDG Flow meter-8

Parameter Electrode selection Material Corrosion Resistance Molybdenum-containing stainless steel Applicable: Domestic/industrial water, sewage, weak acid and alkali saline as well as concentrated nitric acid at room temperature. Not Applicable : Hydrofluoric acid, hydrochloric acid, chlorine, bromine, iodine and other media. Applicable: Non-oxidizing acid, such as hydrochloric acid and hydrofluoric acid of certain concentration and other alkali liquor with a concentration of no less than 70% sodium hydroxide Not Applicable: Nitric acid and other oxidizing acids Applicable: corrosion by oxidizing...

 Open the catalog to page 8
SUP-LDG Flow meter-10

Flow Range Nominal Diameter (mm) Reduction formula: (Flow )Q = (flow velocity) V×π×(DN/2)2,Unit: m/s and m3/h

 Open the catalog to page 10
SUP-LDG Flow meter-12

Parameter ★ Process connection Clamp on (Stainless steel) Flange (Stainless steel) Flange (Carbon steel) ★ Location Do not install the electromagnetic flowmeter on a free-vibrating pipe without any support. Instead, a mounting base shall be used to secure the measuring tube. When the electromagnetic flowmeter is required to be installed underground, the pipes at both inlet and outlet ends shall be provided with support items, and a metal protection plate shall be installed above the flowmeter.

 Open the catalog to page 12
SUP-LDG Flow meter-13

(1) No bubbles shall be observed in the pipes. (3) The electromagnetic flowmeter cannot be installed Pipes shall be designed to prevent the air bubbles in the on the suction side of the pump fluids from accumulating the measurement pipe of a sensor. If a valve exists near the flowmeter, try to mount the flowmeter on the valve’s upstream side for preventing a decrease of pressure inside the pipe possibly, consequently avoiding the possibility of air bubbles. ensure that no gas can be separated from the liquid. (4) For long pipelines, control valves are generally installed on the downstream of...

 Open the catalog to page 13
SUP-LDG Flow meter-14

(7) Measurement error caused by incidental gas and damage of lining caused by vacuum shall be avoided As the voltage of induced signal of electromagnetic flowmeter is small, it’s more prone to be affected by noises or other electromagnetic signals. This is why the electromagnetic flowmeter needs to be grounded in many occasions. This functions to form an internal space for shielding external interference through the grounding of flowmeter casing, thereby improving measurement accuracy. Wiring Remote 100-240VAC power supply 24V power supply Relay out Pulse/Frequency output Excitation signal Electrode...

 Open the catalog to page 14
SUP-LDG Flow meter-15

Ordering code LDG-SUP -M1-DN50-J1-D2-I2-V1-P3-T1-E1-L2-G2-B1-IP1 LDG-SUP- Pipe size Power supply Pressure rating Temperature rating Electrode material Lining material Description Compact type Remote type DN10 - DN2000 1.00% 0.50% No output Pulse output 4-20mA output No RS232 RS485 HART Thread installation Flange installation Clamp mounting Clamp installation 220VAC 24VDC Battery powered 0.6MPa 1.0MPa 1.6MPa 2.5MPa 4.0MPa Others ≤60℃(CR/PU) ≤120℃(F4/F46) ≤150℃(PFA) 316L stainless steel Titanium Tantalum Hastelloy B Hastelloy C Platinum Tungsten carbide Neoprene(CR)