Catalog excerpts
RS-150 Sries 150W Single Output Switching Power Supplies Case No: 8017HW 199 x 99 x 38 mm Features Protections:Short circuit/Over load/Over voltage 镕 Cooling by free air convection LED indicator for power on Օ 100% full load burn-in test All using 105°C long life electrolytic capacitors Օ Withstand 300VAC surge input for 5 second High operating temperature up to 70°C Օ Withstand 5G vibration test High efficiency, long life and high reliability *1»ESCBCՀ Spcification Voltage 88V ~ 132VAC/176~264VAC selectable by switch universal full range or 248V ~ 373VDC Frequency 47 -- 63 Hz INPUT Current <3A@115VAC 2A@230VAC input, full load Inrush Current <40A@230VAC input, Cold start at 25°c ambient Leakage Current <2.0mA@240VAC input OUTPUT MODEL No. RS-150-3.3 RS-150-5 RS-150-12 RS-150-15 RS-150-24 RS-150-48 Voltage 3.3V 5V 12V 15V 24V 48V Rated Current 30A 26A 12.5A 10A 6.5A 3.3A Current Range 0~30A 0~26A 0~12.5A 0~10A 0~6.5A 0~3.3A Voltage Adj. Range 3.2~3.5V 4.75~5.5V 11.4~13.2V 14.25~16.5V 22.8~26.4V 45.6~52.8V Output Tolerance ± 3% ± 2% ± 1% ± 1% ± 1% ± 1% Line Regulation ± 0.5% ± 0.5% ± 0.5% ± 0.5% ± 0.5% ± 0.5% Load Regulation ± 2% ± 1% ± 0.5% ± 0.5% ± 0.5% ± 0.5% Ripple Noise MAX. 80mV 80mV 120mV 120mV 120mV 200mV Efficiency (TYP.) 74% 78% 83% 84% 86% 87% Power 99W 130W 150W 150W 156W 158.4W Over Voltage 3.8~4.45V 5.75~6.75V 13.8~16.2V 17.25~20.25V 27.6~32.4V 55.2~64.8V PROTECTION Hiccup mode, recovers automatically after fault condition is removed Over Load When the power supply is over 110%~ 150% max load or short circuited it will go into hiccup mode and recover automatically after the fault is removed. Rise Time ELEC. CHAR. Hold up Time <20mS@230VAC, 30ms@115VAC at full load >28mS@230V, 20mS@115VAC at full load Setup Time <0.8 Sec@230VAC , 1.2@115VAC ENVIRONMENT Temperature Operating: -25 ~ +70c ; Storage: -40~ +85c Humidity Operating: 20% ~ 90% RH; Storage: 10% ~ 95% RH (non condensing) Withstand Voltage I/P-O/P:3KVAC, I/P-FG:1.5KVAC, O/P-FG:0.5KVAC, 1minute SAFETY Isolation Resistance I/P-O/P, I/P-FG, O/P-FG 100MQ/500VDC Safety Standard UL60950-1, TUV EN60950-1 Approved EMC EMI Compliance to EN55022, EN61000-3-2,3 EMS EN61000-4-2,3,4,5,6,8,11, ENV50204, EN61000-6-2 (EN50082-2) Cooling Natural cooling OTHERS M.T.B.F. 244KHrs min. MIL-HDBK-217F (25c) Packing 0.7Kg; 20pcs/15Kg/0.8 CUFT 1 All parameters NOT specially mentioned are measured at 230VAC input, rated load and 25c of ambient temperature. 2 Ripple & noise are measured at 20MHz of bandwidth by using a 12" twisted pair-wire terminated with a 0.1uf & 47uf parallel capacitor. 3 Tolerance : includes set up tolerance, line regulation and load regulation. 4 Line regulation is measured from low line to high line at rated load. 5 Load regulation is measured from 0% to 100% rated load. 6 The power supply is considered a component which will be installed into a final equipment. The final equipment must be re-confirmed that it still meets EMC directives. 7 Length of set up time is measured at cold first start. Turning ON/OFF the power supply very quickly may lead to increase of the set up time. Sunpower Technology LLP Orion House, Calleva Park, Aldermaston, Berkshire RG7 8SN Tel: +44 (0)118 981 1001 闕 E-mail: sales@sunpower-uk.com
Open the catalog to page 1RS-150 Sries 150W Single Output Switching Power Supplies Block Diagram 230 50115 I/P o- EMI FILTER RECTIFIERS & FILTER POWER SWITCHING RECTIFIERS & FILTER -o +V -o -V FG o- CONTROL DETECTION CIRCUIT O.L.P. O.V.P. - De-Rating Curve Static Characteristics Ta=25c 100 N. \ Others 80 Xv 60 3.3V,5V ^ 40 - 20 - 40 -25 -25 10 20 30 40 Ambient Temprature (°C) 50 60 7驎HEoRRizoNi)rAL) 88 176 95 190 100 200 115 230 120 240 132 264 Input Voltage (VAC) 60Hz Dimensions 197 Terminal Pin. No Assignment: m m ML Pin No. Assignment 1 AC/L 2 AC/N 3 FG 4 DC OUTPUT -V 5 DC OUTPUT +V 4.5, 57.5 120 199 6.5 190 t 22...
Open the catalog to page 2All Sunpower UK catalogs and technical brochures
-
HLG-100H Series
4 Pages
-
ELN-60-D Series
3 Pages
-
ELN-30-D Series
3 Pages
-
CLG-100 Series
3 Pages
-
CEN-75 Series
3 Pages
-
CEN-60 Series
3 Pages
Archived catalogs
-
1000W Front End Power System
8 Pages