Catalog excerpts
HDP-190 Sries 190W Dual Output Enclosed Power Supply with PFC Features Universal AC input/ Full range 镕 Built-in active PFC function, PF>0.94 Protections: Short Circuit/Overload/ Over Voltage/ Over temperature Օ Cooling by free air convection 1U low profile 36mm Օ Conformal coated ZVS technology to reduce power dissipation Օ LED indicator for power on case no: 8019kf 215 x 115 x 36 mm Spcification Voltage 90V ~ 264VAC universal full range or 127V ~ 370VDC. Frequency 47 -- 63 Hz INPUT Current <2.7A@115VAC; 1.1A@230VAC input, full load Inrush Current <30A@115V , <45A@230V AC input, Cold start at 25°c ambient Leakage Current <2.0mA@240VAC input MODEL No. HDP-190 Output No. V1 V2 Voltage 3.8V 2.8V Min Load 0A 0A OUTPUT Max Load 40A 22A Output Tolerance ± 2% ± 2% Line Regulation ± 0.5% ± 0.5% Load Regulation ± 2% ± 2% Ripple Noise MAX. 100mV 100mV Efficiency (TYP.) 86% Power 181.4W V1 total power output shall not exceed 160W; V2 total power output shall not exceed 66W (The V1 & 2 combined total power output shall not exceed 192W) Over Voltage 4.37~5.13V 3.22~3.78V Shutdown o/p voltage, re-power on to recover PROTECTION Over Temperature 95°C ± 5°C (TSW1) detect on heatsink of power transistor; Shut down o/p voltage, re-power on to recover Over Load V1 + V2: 105~150% max. Output power; or V2: 125~170% rated current Hiccup mode, recovers automatically after fault condition is removed Rise Time <50mS@ 115~230VAC at full load ELEC. CHAR. Hold up Time >16mS@ 115~230VAC at full load Setup Time <1.0 Sec @ 230VAC; 2.5 Sec @ 115VAC ENVIRONMENT Temperature Operating: -30 ~ +70c ; Storage: -40~ +85c Humidity Operating: 20% ~ 90% RH; Storage: 10% ~ 95% RH (non condensing) Withstand Voltage I/P-O/P:3KVAC, I/P-FG:1.5KVAC, O/P-FG:0.5KVAC, 1minute SAFETY Isolation Resistance I/P-O/P, I/P-FG, O/P-FG 100MQ/500VDC Safety Standard UL60950-1; TUV EN60950-1 Approved EMC EMI EN55022; EN61000-3-2,3 EMS EN61000-4-2,3,4,5,6,8,11; EN55024; EN61000-6-2 Cooling Natural cooling OTHERS M.T.B.F. 111.3K hrs min. MIL-HDBK-217F (°C) Packing 0.95Kg; 15pcs/15.3Kg/0.7 CUFT 1 All parameters NOT specially mentioned are measured at 230VAC input, rated load and 25°C of ambient temperature 2 Ripple & noise are measured at 20MHz of bandwidth by using a 12" twisted pair-wire terminates with a 0.1uf & 47uf parallel capacitor 3 Tolerance: Includes set up tolerance, line regulation and load regulation 4 The power supply is considered a component of end-equipment. The end-equipment must be re-confirmed whether comply with EMC directives. 5 Derating may be needed under low input voltages. Please check the derating curve for more details 6 Output voltage between V1 and V2 should be higher tahn 0.8V (V1-V220.8V) Sunpower Technology LLP Orion House, Calleva Park, Aldermaston, Berkshire RG7 8SN Tel: +44 (0)118 981 1001 闕 E-mail: sales@sunpower-uk.com
Open the catalog to page 1HDP-190 Sries 190W Dual Output Enclosed Power Supply with PFC Block Diagram I/P o- EMI FILTER <L|JMRTENNGT o+V1 o COM FG o- +V2 De-Rating Curve Output De-Rating Vs. Input Voltage 100 100 90 80 70 80 20 50 40 10 20 30 40 50 Ambient Temperature (°C) 70 (HORIZONTAL) 90 95 100 115 130 145 165 185 205 225 245 264 Input Voltage (V) 60Hz Dimensions 215 Terminal Pin. No Assignment: Pin No. Assignment 1 AC/L 2 AC/N 3 FG 4,5 V2 (+2.8V) 6,7 V1 (+3.8V) 8~11 COM 215 16max - 32.5 150 !.. < =1 4-M4 L=5mm Sunpower Technology LLP Orion House, Calleva Park, Aldermaston, Berkshire RG7 8SN Tel: +44 (0)118 981...
Open the catalog to page 2All Sunpower UK catalogs and technical brochures
-
HLG-100H Series
4 Pages
-
ELN-60-D Series
3 Pages
-
ELN-30-D Series
3 Pages
-
CLG-100 Series
3 Pages
-
CEN-75 Series
3 Pages
-
CEN-60 Series
3 Pages
Archived catalogs
-
1000W Front End Power System
8 Pages