CEN-60 Series
3Pages

{{requestButtons}}

Catalog excerpts

CEN-60 Series - 1

CEN-60 Series 60W IP66 Constant Voltage LED Lighting Power Supplies Features • • • • • • • • • Universal AC input up to 295VAC Adjustable output voltage & constant current levels IP66 level for indoor and outdoor applications Built in active PFC function Short circuit, over current, over voltage, over temperature protections Cooling by free air convection High reliability Compliance to worldwide safety regulations for lighting Suitable for dry, damp, wet locations Specification Voltage Inrush Current Leakage Current Power Factor PF>0.97/115VAC, PF>0.95/230VAC, PF>0.9/277VAC at full load (Please refer to "Power Factor Characteristic" curve) MODEL No. Voltage Voltage Adj. Range Constant Current Operation OUTPUT Rated Current Current Adj, Range Power Ripple & Noise Over Voltage Shutdown output voltage, re-power on to recover PROTECTION Short Circuit Hiccup mode, recovers autimatically after fault condition is removed Over Temperature 85℃ ±10℃ (RTH1); shutdown output voltage, re-power on to recover Over Current 95~110%; constant current limiting, recovers automatically after fault condition is removed Voltage Tolerance Load Regulation Setup Time ELEC. CHAR. Line Regulation Operating: -30~+70℃ ; De-rating: 50~70℃@60% load ; Storage: -40~ +80℃ Operating: 20%~95% RH; Storage: 10%~95% RH (non condensing) ±0.03%/℃ (0~50℃) 10~500Hz, 5G 12min./1cycle, period for 72min. each along X, Y, Z axes Withstand Voltage Isolation Resistance I/P-O/P, I/P-FG, O/P-FG:>100M Ohms / 500VDC / 25℃/ 70% RH Safety Standard Humidity Temp. Coefficient Compliance to EN61000-4-2,3,4,5,6,8,11, EN55024, EN61547, light industry level (surge 4KV), criteria A M.T.B.F. OTHERS Compliance to EN55015, EN61000-3-2 Class C (75% load) ; EN61000-3-3 1. All parameters NOT specially mentioned are measured at 230VAC input, rated load and 25℃ of ambient temperature. 2. Ripple & noise are measured at 20MHz of bandwidth by using a 12" twisted pair-wire terminated with a 0.1uf & 47uf parallel capacitor. 3. Tolerance : includes set up tolerance, line regulation and load regulation. 4. Derating may be needed under low input voltage. Please check the static characteristics for more details. 5. Constant current operation region is within 75% ~ 100% rated output voltage. This is the suitable operation region for LED related applications, but please reconfirm special electrical requirements foR specific system design. 6. The power supply is considered a component that will be operated in combination with final equipment. Since EMC performance will be affected by the complete installation, the final equipment manufacturers must re-qualify EMC Directive on the complete installation. 7. Direct connecting to LEDs is suggested, but is not suitable for using additional drivers. Sunpower Technology LLP Orion House, Calleva Park, Aldermaston, Berkshire RG7 8SN Tel: +44 (0)118 981 1001 • E-mail: sales@sunpower-uk.com

Open the catalog to page 1
CEN-60 Series - 2

60W IP66 Constant Voltage LED Lighting Power Supplies Block Diagram De-Rating Curve Static Characteristics Sunpower Technology LLP Orion House, Calleva Park, Aldermaston, Berkshire RG7 8SN Tel: +44 (0)118 981 1001 • E-mail: sales@sunpower-uk.com

Open the catalog to page 2
CEN-60 Series - 3

CEN-60 Series 60W IP66 Constant Voltage LED Lighting Power Supplies Power Factor Characteristics Efficiency vs Load (48V Model) Constant Current Mode Driving Method For LED Module 100 Constant Current area Typical LED power supply I-V curve Sunpower Technology LLP Orion House, Calleva Park, Aldermaston, Berkshire RG7 8SN Tel: +44 (0)118 981 1001 • E-mail: sales@sunpower-uk.com

Open the catalog to page 3

All Sunpower UK catalogs and technical brochures

Archived catalogs