SYS1888-1505
2Pages

{{requestButtons}}

Catalog excerpts

SYS1888-1505 - 1

Wall mount GREEN MODE Country of Origin : Operating Temperature : Approvals / Marks : Features: Certified plugs Wxx = W2E - Europe | W3U - England | W2 - USA, Canada, Japan,Taiwan | W2A - Australia | T2 - Desktop Output connector: standard: 2.1 x 5.5 x 11mm or customer requirement | Regulated Output With Low Ripple Noise | Safety Agency Requirements and EMI/EMS Certified Private Label Marking Available | Modified and Custom Design Available | 2 Years Warranty Turn delay 3000ms max@AC low line input@output full load 8ms min@AC nominal input@output full load Efficiency (Normal) >84.3%@115v/60HZ,230V/50HZ input &Full load Transient response (dv,tmax) 0.4V dv max At AC nominal input loading from 20%load to 80% load 16ms tmax Dynamic rise time 10 us max,duty 40ms max,Dynamic load step is slew rate of 0.5A/us Power out.Limit Dielectric Strength (Hi-pot) Power consumption 0.1W max. At AC nominal input@output min load 50,000 Calculated Hours at 25ºC, according to the MIL-STD217F Cable Length 1370mm (4.5 feet) standard cable or as required Line power surge | Line voltage SAG-more info on request INPUT Voltage PLD (power line disturbance) 0.5A rms@AC low line input and DC output full load Cooling method Natural Convection Cooling Inrush Surge Current (cold start) 30/40A max@power supply cold start,ambient temperature 25°C @100Vac/240Vac nominal AC input Housing material leakage current Temperature coefficient: PROTECTION Over current/ Short protection The power supply will be auto recovered when over current or short circuit faults remove (fold back). Is defined as any output impedance of less than 0.1Ω.The power supply will be auto recovered when short circuit faults remove Over Voltage The power supply will not be auto recovered when faults remove 110%-150%. (Voltage limit) Input protection F1:1A 250V Fuse The power supply shall be protected against power line surges and any abnormal condition The power supply is provided with no load operation to prevent the power supply and system from damage. Protection class Operating: 0~40℃ / Storage: -20%~80%RH non condensing Operating: 8%~90%RH / Storage: 5%~90% RH non condensing

Open the catalog to page 1
SYS1888-1505 - 2

Wall mount Mechanical case specification: Cable specification:

Open the catalog to page 2

All Sunny catalogs and technical brochures

  1. SYS1541-1505

    2 Pages

  2. SYS1529-1205

    2 Pages

  3. SYS1561-1105

    2 Pages

  4. SYS1121-Wxx

    2 Pages