1. Catalogs
  2. Sunny
  3. SYS1888-1505

SYS1888-1505

SYS1888-1505

SYS1888-1505

Product catalog summary
Specifications:
The SYS1888-Wxx/T2 series is a wall mount power supply with an operating temperature range of 0 to 40°C and dimensions of 64 x 27 x 76 mm. It is manufactured in China and has an efficiency level of VI. The power supply is available in various models with different voltage outputs ranging from 5V to 24V, all with a maximum power output of 18W and a ripple/noise level of 200 mV p-p. The standard output connector is 2.1 x 5.5 x 11 mm, with options for customization.
Features:
The power supply includes certified plugs for different regions, regulated output with low ripple noise, and compliance with safety agency requirements and EMI/EMS certifications. It offers private label marking, modified and custom design options, and a 2-year warranty.
Output Specifications:
The power supply has a turn delay of 3000ms max, a hold-up time of 8ms min, and an efficiency greater than 84.3% at full load. It features a transient response with a maximum dv of 0.4V and a dynamic rise time of 10 us max. The power output limit is 18W, with a burn-in limit of 4 hours at 40°C.
Input Specifications:
The input voltage range is 90-264VAC with a frequency of 50-60Hz. The current is 0.5A rms at full load, and the inrush surge current is 30/40A max at a cold start. The leakage current is 5mA max.
Protection:
The power supply includes overcurrent/short protection, overvoltage protection, input protection with a 1A 250V fuse, no-load protection, and is classified as protection class II.
Safety and Compliance:
The power supply complies with CE, EMC 2014/30/EU, LVD 2014/35/EU, EN 60950-1, EN 62368-1, and various safety certifications including cTUVus, FCC, GS, CE, CB, RCM, SAA, PSE, and UKCA.
Other Specifications:
It has a dielectric strength of 3000VAC, an M.T.B.F of 50,000 hours at 25ºC, and a standard cable length of 1370mm. The cooling method is natural convection, and the housing material is PC + ABS.
Environmental Conditions:
The operating temperature is 0-40°C with humidity levels of 8-90% RH. Storage conditions are -20-80% RH non-condensing.
Weight and Packing:
The net weight is 105g per piece plus plug, and the gross weight is 122g per piece plus plug. The packing includes 100 pieces per box.
Mechanical and Cable Specifications:
The mechanical case and cable specifications vary based on the voltage, with different AWG ratings for different voltage outputs. The power supply is available in various plug types for different regions.
See more

Catalog excerpts

SYS1888-1505-1

Wall mount GREEN MODE Country of Origin : Operating Temperature : Approvals / Marks : Features: Certified plugs Wxx = W2E - Europe | W3U - England | W2 - USA, Canada, Japan,Taiwan | W2A - Australia | T2 - Desktop Output connector: standard: 2.1 x 5.5 x 11mm or customer requirement | Regulated Output With Low Ripple Noise | Safety Agency Requirements and EMI/EMS Certified Private Label Marking Available | Modified and Custom Design Available | 2 Years Warranty Turn delay 3000ms max@AC low line input@output full load 8ms min@AC nominal input@output full load Efficiency (Normal) >84.3%@115v/60HZ,230V/50HZ input &Full load Transient response (dv,tmax) 0.4V dv max At AC nominal input loading from 20%load to 80% load 16ms tmax Dynamic rise time 10 us max,duty 40ms max,Dynamic load step is slew rate of 0.5A/us Power out.Limit Dielectric Strength (Hi-pot) Power consumption 0.1W max. At AC nominal input@output min load 50,000 Calculated Hours at 25ºC, according to the MIL-STD217F Cable Length 1370mm (4.5 feet) standard cable or as required Line power surge | Line voltage SAG-more info on request INPUT Voltage PLD (power line disturbance) 0.5A rms@AC low line input and DC output full load Cooling method Natural Convection Cooling Inrush Surge Current (cold start) 30/40A max@power supply cold start,ambient temperature 25°C @100Vac/240Vac nominal AC input Housing material leakage current Temperature coefficient: PROTECTION Over current/ Short protection The power supply will be auto recovered when over current or short circuit faults remove (fold back). Is defined as any output impedance of less than 0.1Ω.The power supply will be auto recovered when short circuit faults remove Over Voltage The power supply will not be auto recovered when faults remove 110%-150%. (Voltage limit) Input protection F1:1A 250V Fuse The power supply shall be protected against power line surges and any abnormal condition The power supply is provided with no load operation to prevent the power supply and system from damage. Protection class Operating: 0~40℃ / Storage: -20%~80%RH non condensing Operating: 8%~90%RH / Storage: 5%~90% RH non condensing

 Open the catalog to page 1
SYS1888-1505-2

Wall mount Mechanical case specification: Cable specification: