Catalog excerpts
Wall mount SYS1638-Wxx series GREEN MODE Operating Temperature : Approvals / Marks : Features: Certified plugs Wxx = W2E - Europe | W3U - England | W2 - USA, Canada, Japan,Taiwan | W2C - China | W2K - Korea Output connector: standard: 2.1 x 5.5 x 11mm or customer requirement | Regulated Output With Low Ripple Noise | Safety Agency Requirements and EMI/EMS Certified Private Label Marking Available | Modified and Custom Design Available | 2 Years Warranty Turn delay 3000ms max@AC low line input@output full load 5ms min@AC nominal input@output full load Efficiency (Normal) >79.03%@115v/60HZ,230V/50HZ input &Full load Transient response (dv,tmax) 0.6V dv max At AC nominal input loading from 20%load to 80% load Dynamic rise time 10 us max,duty 40ms max,Dynamic load step is slew rate of 0.5A/us Power out.Limit Full load 2 Hours Power consumption 0.075W max. At AC nominal input@output min load Dielectric Strength(Hi-pot) M.T.B.F 0.5A rms@AC low line input and DC output full load Inrush Surge Current (cold start) 40/60A max@power supply cold start,ambient temperature 25ºC @115Vac/230Vac nominal AC input leakage current Line power surge | Line voltage SAG-more info on request Cooling method 1500mm (5 feet) standard cable or as required PLD (power line disturbance) 500,000 Calculated Hours at 25ºC, by Telcordia SR-332 Cable Length Natural Convection Cooling Housing material Temperature coefficient: ENVIRONMENT Temperature Operating: 8%~90%RH / Storage: 5%~95% RH non condensing Over current/ Short protection The power supply will be auto recovered when over current or short circuit faults remove (fold back). Is defined as any output impedance of less than 0.1Ω.The power supply will be auto recovered when short circuit faults remove Over Voltage The power supply will not be auto recovered when faults remove 110%-150%. (Voltage limit) Input protection F1 1A/250V Fuse The power supply shall be protected against power line surges and any abnormal condition The power supply is provided with no load operation to prevent the power supply and system from damage. Protection class
Open the catalog to page 1Wall mount Mechanical case specification: 1) SYS1638-series (EU) Mechanical specification (country housing): US / Japan type (W2)
Open the catalog to page 2All Sunny catalogs and technical brochures
-
SYS1575-9012-M3
2 Pages
-
ATS 065T-P480
2 Pages
-
SYS1548-5012-T3
2 Pages
-
SYS1548-5012-T2
2 Pages
-
SYS1546-3612-T3
2 Pages
-
SYS1546-3612-T2
2 Pages
-
SYS1588-2709-T2
2 Pages
-
SYS1319-3015-T3
2 Pages
-
SYS1544-2412-T3
2 Pages
-
SYS1544-2412-T2
2 Pages
-
SYS1001-1212-T2
2 Pages
-
SYS1001-0612-T2
2 Pages
-
SYS1541-1505
2 Pages
-
SYS1308N-1505-W2E
2 Pages
-
SYS1888-1505
2 Pages
-
SYS1530-1215-W2E
2 Pages
-
SYS1529-1205
2 Pages
-
SYS1381N-1205-W2E
2 Pages
-
SYS1561-1105
2 Pages
-
SYS1121-Wxx
2 Pages
-
SYS1121-Wxx series
2 Pages
-
SYS1001-Wxx series
2 Pages
-
SYS1052-W2E series
2 Pages
-
SYS1001-W2E series
2 Pages