1. Catalogs
  2. Sunny
  3. SYS1588-2709-T2

SYS1588-2709-T2
1 /2Pages

SYS1588-2709-T2

SYS1588-2709-T2
1 /2Pages

Catalog excerpts

SYS1588-2709-T2-1

GREEN MODE Country of Origin : Operating Temperature : Approvals / Marks : Features: Available in inlet version: C7 (T2) Output connector: standard: 2.1 x 5.5 x 11mm or customer requirement | Regulated Output With Low Ripple Noise | Safety Agency Requirements and EMI/EMS Certified Private Label Marking Available | Modified and Custom Design Available | 2 Years Warranty Turn delay 5000 ms max@AC low line input@output full load 8ms min@AC nominal input@output full load Efficiency (Normal) >85%@115v/60HZ,230V/50HZ input &Full load Transient response (dv,tmax) 0.4V dv max At AC nominal input loading from 20%load to 80% load 16ms tmax Dynamic rise time 10 us max,duty 40ms max,Dynamic load step is slew rate of 0.5A/us Power out.Limit Full load 2 Hours Dielectric Strength Power consumption 0.1W max. At AC nominal input@output min load 500,000 Calculated Hours at 25ºC, by Telcordia SR-332 Cable Length 1500mm (5 feet) or 1830mm (6 feet) standard cable or as required INPUT Voltage PLD (power line disturbance) Line power surge | Line voltage SAG-more info on request 1.5A rms@AC low line input and DC output full load Cooling method Natural Convection Cooling Inrush Surge Current (cold start) 40/60A max@power supply cold start,ambient temperature 25°C @115Vac/230Vac nominal AC input Housing material leakage current 5mA maximum,At nominal AC input voltage and frequency. Temperature coefficient: PROTECTION Over current/ Short protection The power supply will be auto recovered when over current or short circuit faults remove (fold back). Is defined as any output impedance of less than 0.1Ω.The power supply will be auto recovered when short circuit faults remove Over Voltage he power supply shall be self-recovering when the fault condition is removed. Input protection The switching adaptor use 2.0A fuse. The power supply is provided with no load operation to prevent the power supply and system from damage. Protection class II, (ITU-T K.21 Surge 6KV on request) Operating: 8%~90%RH / Storage: 5%~95% RH non condensing

 Open the catalog to page 1
SYS1588-2709-T2-2

Mechanical case specification: Cable specification:

 Open the catalog to page 2

All Sunny catalogs and technical brochures

  1. ATS 065T-P480

    2  Pages

  2. SYS1541-1505

    2  Pages

  3. SYS1888-1505

    2  Pages

  4. SYS1529-1205

    2  Pages

  5. SYS1561-1105

    2  Pages

  6. SYS1121-Wxx

    2  Pages

*Prices are pre-tax. They exclude delivery charges and customs duties and do not include additional charges for installation or activation options. Prices are indicative only and may vary by country, with changes to the cost of raw materials and exchange rates.