Specifications:
The document outlines the specifications for the SYS1548-T3 series power supplies, detailing models with varying voltage outputs (12V to 36V), loading capacities, maximum power, ripple/noise levels, and connector sizes. Key models include SYS1548-5012-T3 and SYS1548-6524-T3, among others.

Features:
The power supplies are available in two inlet versions (C7 and C13) and offer regulated output with low ripple noise. They meet safety agency requirements and are EMI/EMS certified. Custom designs and private label marking are available, with a two-year warranty.

Performance and Efficiency:
The power supplies have a turn delay of 3000 ms max and a hold-up time of 5 ms min. They meet efficiency standards such as CEC, DOE, ERP, and MEPS Level VI. The transient response is specified with a maximum dv of 0.4V and a dynamic rise time of 10 us max.

Input and Protection:
Input voltage ranges from 90 to 264 VAC with a frequency of 47 to 63 Hz. The power supplies feature overcurrent, short circuit, and overvoltage protection, with auto-recovery capabilities. They include a 3.15A 250V fuse for input protection and are designed for no-load operation.

Safety and Compliance:
The power supplies comply with various safety standards, including CB, CE, GS, FCC, and more. They have a dielectric strength of 3000VAC and an M.T.B.F of 500,000 hours at 25ºC.

Environmental Conditions:
Operating temperature ranges from 0 to 40°C, with storage temperatures from -20 to 85°C. Humidity levels for operation are 8% to 90% RH, and for storage, 5% to 95% RH.

Physical Characteristics:
The power supplies weigh 300g per unit, with a gross weight of 16kg per box. They are packed in PE plastic bags, with 60 units per box.

Additional Information:
The document also mentions the use of natural convection cooling, housing materials (PC or PPO), and a temperature coefficient of less than ±0.5% / °C. The cable length is standard at 1500mm, with options for customization.
See more

Catalog excerpts

SYS1548-5012-T3-1

GREEN MODE Country of Origin : Operating Temperature : Approvals / Marks : Features: Available in 2 inlet versions: C7 (T2) C13(T3) Output connector: standard: 2.1 x 5.5 x 11mm or customer requirement | Regulated Output With Low Ripple Noise | Safety Agency Requirements and EMI/EMS Certified Private Label Marking Available | Modified and Custom Design Available | 2 Years Warranty Turn delay 3000 ms max@AC low line input@output full load 5ms min@AC nominal input@output full load (>half cycle) Efficiency (Normal) Meet CEC,DOE,ERP,MEPS Level VI@115v/60HZ,230V/50HZ Transient response (dv,tmax) 16ms tmax Dynamic rise time 10 us max,duty 40ms max,Dynamic load step is slew rate of 0.5A/us 0.4V dv max At AC nominal input loading from 20%load to 80%load SAFETY CB | CE | GS | FCC | cULus | CCC | BSMI | PSE | KC(only12V) | SAA | RCM | NOM (only5012/6012) | UKCA | EAC(only5012) | BIS(only6512/6012/5012) | S-MARK | STCOA Power out.Limit Full load 2 Hours Dielectric Strength Power consumption Less than 0.075W ms max. At AC nominal input@output min load 500,000 Calculated Hours at 25ºC, by Telcordia SR-332 Cable Length 1500mm (5 feet) standard cable or as required PLD (power line disturbance) Line power surge | Line voltage SAG-more info on request Cooling method Natural Convection Cooling Housing material Temperature coefficient: INPUT Voltage 2.0A rms@AC low line input and DC output full load Inrush Surge Current (cold start) 40/80A max@power supply cold start,ambient temperature 25°C @115Vac/230Vac nominal AC input leakage current Operating: 8%~90%RH / Storage: 5%~95% RH non condens- Over current/ Short protection The power supply will self-protect any output to ground & auto recovery when abnormal circuit faults remove. An output short circuit is defined as any output impedance less than 0.1 ohms. Over Voltage The power supply will be auto recovered when faults remove Input protection F1:3.15A 250V Fuse The power supply shall be protected against power line surges and any abnormal condition The power supply is provided with no load operation to prevent the power supply and system from damage. Protection class I, (ITU-T K.21 Surge 6KV on request)

 Open the catalog to page 1
SYS1548-5012-T3-2

Mechanical case Cable specification:

 Open the catalog to page 2

All Sunny catalogs and technical brochures

  1. ATS 065T-P480

    2  Pages

  2. SYS1541-1505

    2  Pages

  3. SYS1888-1505

    2  Pages

  4. SYS1529-1205

    2  Pages

  5. SYS1561-1105

    2  Pages

  6. SYS1121-Wxx

    2  Pages

*Prices are pre-tax. They exclude delivery charges and customs duties and do not include additional charges for installation or activation options. Prices are indicative only and may vary by country, with changes to the cost of raw materials and exchange rates.