Specifications:
Country of Origin: China
Operating Temperature: 0~40°C
Dimension: 115 x 55 x 35 mm
Efficiency Level: VI

Model Specifications:
  • SYS1548-5012-T2: 12V, 0~4.17A, 50W, 200mV ripple, 2.1x5.5x11mm connector
  • SYS1548-5024-T2: 24V, 0~2.08A, 50W, 240mV ripple, 2.1x5.5x11mm connector
  • SYS1548-6512-T2: 12V, 0~5.42A, 65W, 180mV ripple, multiple connector options
  • SYS1548-6515-T2: 15V, 0~4.33A, 65W, 200mV ripple, 2.1x5.5x11mm connector
  • SYS1548-6518-T2: 18V, 0~3.61A, 65W, 240mV ripple, 2.1x5.5x11mm connector
  • SYS1548-6519-T2: 19V, 0~3.42A, 65W, 240mV ripple, 2.1x5.5x11mm connector
  • SYS1548-6524-T2: 24V, 0~2.71A, 65W, 300mV ripple, 2.1x5.5x11mm connector
  • SYS1548-6536-T2: 36V, 0~1.80A, 65W, 360mV ripple, 2.1x5.5x11mm connector

Features:
Available in C7 (T2) and C13 (T3) inlet versions. Output connector is standard or customizable. Regulated output with low ripple noise. Safety agency requirements and EMI/EMS certified. Private label marking and custom design available. 2-year warranty.

Approvals/Marks:
Output: Turn delay 3000 ms max, hold up time 5ms min, efficiency meets CEC, DOE, ERP, MEPS Level VI. Transient response: 0.4V dv max, 16ms tmax. Power out limit: Peak 75W. Burn in limit: Full load 2 hours. Power consumption: Less than 0.075W.

Input:
Voltage: 90~264VAC, Frequency: 47~63Hz, Current: 2.0A rms. Inrush surge current: 40/80A max. Leakage current: T2: 0.25mA max, T3: 3.0mA max.

Protection:
Over current/short protection with auto recovery. Over voltage auto recovery. Input protection with 3.15A 250V fuse. No load protection. Protection class II.

Safety:
Complies with CE, EMC 2014/30/EU, LVD 2014/35/EU, EN 60950-1, EN 62368-1. Certifications: CB, CE, GS, FCC, cULus, SAA, RCM, UKCA.

Others:
Dielectric strength: 3000VAC. M.T.B.F: 500,000 hours. Cable length: 1500mm standard. Cooling method: Natural convection. Housing material: PC or PPO. Temperature coefficient: < ±0.5% / °C.

Environment:
Operating temperature: 0~40°C, Storage temperature: -20~85°C. Operating humidity: 8%~90% RH, Storage humidity: 5%~95% RH non-condensing.

Weight and Packing:
Net weight: 290g/pc, Gross weight: 16kg/box. Packing: 60 pcs/box, 48x44x23 cm.

Mechanical Case Specification:
UNI cable type and FIX cable type specifications provided. Various connector types available for different applications.
See more

Catalog excerpts

SYS1548-5012-T2-1

GREEN MODE Country of Origin : Operating Temperature : Approvals / Marks : Features: mentioned or It will be provide with the specify model per request. “E” - 4.2 x 6.0 x 10 CenterPINØ1.4mm (black) for LCD (DELL+LG) “B” - 2.1 x 5.5 x 9.5 (black) for common use “M” - 2.5 x 5.5 x 11.5 (white) for LCD ACER “D” - 3.0 x 6.3 x 9 (green) for LCD ACER “Е” - 1.7 x 5.5 x 11.5 (yellow) Available in 2 inlet versions: C7 (T2) C13(T3) Output connector: standard: 2.1 x 5.5 x 11mm or customer requirement | Regulated Output With Low Ripple Noise | Safety Agency Requirements and EMI/EMS Certified Private Label Marking Available | Modified and Custom Design Available | 2 Years Warranty Turn delay 3000 ms max@AC low line input@output full load 5ms min@AC nominal input@output full load (>half cycle) Efficiency (Normal) Meet CEC,DOE,ERP,MEPS Level VI@115v/60HZ,230V/50HZ Transient response (dv,tmax) 0.4V dv max At AC nominal input loading from 20%load to 80% load 16ms tmax Dynamic rise time 10 us max,duty 40ms max,Dynamic load step is slew rate of 0.5A/us SAFETY CB | CE | GS | FCC | cULus | SAA | RCM | UKCA Power out.Limit Full load 2 Hours Dielectric Strength Power consumption Less than 0.075W ms max. At AC nominal input@output min load 500,000 Calculated Hours at 25ºC, by Telcordia SR-332 Cable Length 1500mm (5 feet) standard cable or as required Line power surge | Line voltage SAG-more info on request PLD (power line disturbance) 2.0A rms@AC low line input and DC output full load Cooling method Natural Convection Cooling Inrush Surge Current (cold start) 40/80A max@power supply cold start,ambient temperature 25°C @115Vac/230Vac nominal AC input Housing material Temperature coefficient: leakage current Operating: 8%~90%RH / Storage: 5%~95% RH non condensing Over current/ Short protection The power supply will self-protect any output to ground & auto recovery when abnormal circuit faults remove. An output short Over Voltage The power supply will be auto recovered when faults remove Input protection F1:3.15A 250V Fuse The power supply shall be protected against power line surges and any abnormal condition The power supply is provided with no load operation to prevent the power supply and system from damage. Protection class II, (ITU-T K.21 Surge 6KV on request)

 Open the catalog to page 1
SYS1548-5012-T2-2

Mechanical case specification: Cable specification: a) UNI cable type (1185#16*1C + shield / 5FT) ---- types of UNI plugs can be changed by customer b) FIX cable type (1185#16 for 12V model, 1185#20 for 24V model)

 Open the catalog to page 2

All Sunny catalogs and technical brochures

  1. ATS 065T-P480

    2  Pages

  2. SYS1541-1505

    2  Pages

  3. SYS1888-1505

    2  Pages

  4. SYS1529-1205

    2  Pages

  5. SYS1561-1105

    2  Pages

  6. SYS1121-Wxx

    2  Pages

*Prices are pre-tax. They exclude delivery charges and customs duties and do not include additional charges for installation or activation options. Prices are indicative only and may vary by country, with changes to the cost of raw materials and exchange rates.