SYS1530-1215-W2E
2Pages

{{requestButtons}}

Catalog excerpts

SYS1530-1215-W2E - 1

Wall mount GREEN MODE Country of Origin : Operating Temperature : Features: PSU housing ready for use in country : Wxx = W2E - Europe | W2 - USA, Canada, Japan Output connector: standard: 2.1 x 5.5 x 11mm or customer requirement | Regulated Output With Low Ripple Noise | Safety Agency Requirements and EMI/EMS Certified Private Label Marking Available | Modified and Custom Design Available | 2 Years Warranty Turn delay 3000 ms max @ AC low line input@output full load 5ms min@AC nominal input@output full load (>half cycle) Efficiency (Normal) Transient response (dv,tmax) Meet CEC,DOE,ERP,MEPS Level VI @115v/60HZ,230V/50HZ 0.4v dv max At AC nominal input loading from 50% load to max load or peak load 16ms tmax | Dynamic rise time 10uS max , duty 40mS max , Dynamic load step is slew rate of 0.5A/uS Power out.Limit Full load 2 Hours Power consumption Less than 0.075W ms max. At AC nominal input@output min load OTHERS Dielectric Strength(Hi-pot) 500,000 Calculated Hours at 25ºC, by Telcordia SR-332 Cable Length 1370mm (4.5 feet) standard 2 wire cable or as required Line power surge | Line voltage SAG-more info on request PLD (power line disturbance) Cooling method Natural Convection Cooling 0.3A rms @ AC low line input and DC output full load Housing material Inrush Surge Current (cold start) 40/60A max@power supply cold start,ambient temperature 25°C @115Vac/230Vac nominal AC input Temperature coefficient: leakage current Operating: 8%~90%RH / Storage: 5%~95% RH non condensing Over current/ Short protection The power supply will self-protect any output to ground & auto recovery when abnormal circuit faults remove. An output short circuit is defined as any output impedance less than 0.1 ohms. Over Voltage The power supply will be auto recovered when faults remove Input protection F1 1A/250V Fuse The power supply shall be protected against power line surges and any abnormal condition The power supply is provided with no load operation to prevent the power supply and system from damage. Protection class II, (ITU-T K.21 Surge 6KV on request)

Open the catalog to page 1
SYS1530-1215-W2E - 2

Wall mount Mechanical case specification: Mechanical specification (country housing): Europe type (W2E) US / Canada / Japan type (W2) Cable specification:

Open the catalog to page 2

All Sunny catalogs and technical brochures

  1. SYS1541-1505

    2 Pages

  2. SYS1888-1505

    2 Pages

  3. SYS1529-1205

    2 Pages

  4. SYS1561-1105

    2 Pages

  5. SYS1121-Wxx

    2 Pages