1. Catalogs
  2. Sunny
  3. SYS1319-3015-T3

SYS1319-3015-T3

SYS1319-3015-T3

SYS1319-3015-T3

Product catalog summary
Product Overview: The SYS1319-T3 series is a 30W desktop power supply designed for I.T.E. use, conforming to RoHS standards. It features a wide input range of 90 to 264 VAC and operates at frequencies between 47 and 63 Hz. The device is suitable for use with IEC320-C13 AC cables and is manufactured in China.
Specifications:
  • Operating Temperature: 0 to 40°C
  • Dimensions: 86.8 x 47.3 x 32.3 mm
  • Efficiency Level: ErP V
  • Approvals/Marks: CE, TUV/GS, CB, cULus, KC (for specific models), FCC
Features:
  • Overload, overvoltage, and short circuit protection with auto recovery.
  • Output connectors are customizable, with a standard size of 2.1 x 5.5 x 11 mm.
  • Designed for use with cable IEC320-C7 and inlet C8 (T2).
Model Specifications:
ModelVoltage (V)Loading (A)Efficiency (%)Max Power (W)Ripple & Noise (mV p-p)
SYS1319-3012-T3120~2.50>83.530120
SYS1319-3015-T3150~2.00>80.630150
SYS1319-3018-T3180~1.66>87.030180
SYS1319-3024-T3240~1.25>84.030240
Input and Protection:
  • Input Voltage: 90 to 264 VAC
  • Frequency: 47 to 63 Hz
  • Current: 1A rms at AC low line input and DC output full load
  • Surge Current: Max 40/60A at cold start
  • Leakage Current: Max 3.5mA
  • Protection: Overload, overvoltage, short circuit with auto recovery
Environmental Conditions:
  • Operating Temperature: 0 to 40°C
  • Storage Temperature: -20 to 85°C
  • Humidity: Operating 8 to 90% RH, Storage 5 to 95% RH non-condensing
Safety and Compliance: The product complies with CE, EMC 2014/30/EU, LVD 2014/35/EU, and EN 60950-1:2006+A11+A1+A12+A2 standards.
Additional Information: The power supply includes a power-on LED, a turn-on delay of 3000 ms max, and a hold-up time of 10 ms at full load. It has a calculated MTBF of 500,000 hours at 25°C.
See more

Catalog excerpts

SYS1319-3015-T3-1

SYS1319-T3 series GREEN MODE Operating Temperature : Efficiency level (ErP) : Approvals / Marks : Features: Wide range Input (90 ~ 264)VAC / (47 ~ 63) Hz. For I.T.E. use only + RoHS conform. Over load, over voltage & short protection. Designed and certified also for cable IEC320-C7 & inlet C8 (T2). Output connector: standard: 2.1 x 5.5 x 11mm or customer requirement. Ripple & Noise [mV]p-p This model is certified for Uout=(5,6,9,12,15,16,18,19,20,24)V and Pout=(5~30)W is rising in steps of 1W Voltage 1A rms@ AC low line input and DC output full load 40/60Amax. @ power supply cold start, ambient temperature 25℃ @115Vac/230Vac nominal AC input. Leakage current Over load Over Voltage Current Surge Current max. Short Circuit Yes, Output to Ground, Auto recovery when fault has been removed. Short Current & Over Current can not exceed 8A max. after 1minute at nominal line input. Protection class Yes, to protect the power supply and system from damage Dielectric Strength 10ms @ AC nominal Input and Output full load MTBF Qualification 500,000 Calculated Hours at 25ºC, by Telcordia SR-332 Standard length of the cable 1,8m & It depends on customer requirements and upon specifications Efficiency (typical) >83.5% @ 240VAC input & Full load Power Consumption Max. 0.3Wrms @ AC nominal Input and Output min. load | some models have achieved efficiency level IV. Input Fuse 3000 ms max. @ AC low line input @ output full load Hold-up Time Operating: (8 ~ 90)% RH / Storage: (5 ~ 95)% RH non condensing protected against power line surges and any abnormal conditions CE | TUV/GS | CB | cULus | KC (Only for SYS1319-3012, SYS1319-3015) | FCC EMC

 Open the catalog to page 1
SYS1319-3015-T3-2

Mechanical case specification: Cable specification: 1185#18*1C + shield / 6FT (1830mm)

 Open the catalog to page 2

All Sunny catalogs and technical brochures

  1. ATS 065T-P480

    2  Pages

  2. SYS1541-1505

    2  Pages

  3. SYS1888-1505

    2  Pages

  4. SYS1529-1205

    2  Pages

  5. SYS1561-1105

    2  Pages

  6. SYS1121-Wxx

    2  Pages

*Prices are pre-tax. They exclude delivery charges and customs duties and do not include additional charges for installation or activation options. Prices are indicative only and may vary by country, with changes to the cost of raw materials and exchange rates.