Catalog excerpts
Wall mount GREEN MODE Country of Origin : Operating Temperature : Approvals / Marks : Features: Certified plugs Wxx = W2E - Europe | W3U - England | W2 - USA, Canada, Japan,Taiwan | W2A - Australia | W2K - Korea | W2C - China Output connector: standard: 2.1 x 5.5 x 11mm or customer requirement | Regulated Output With Low Ripple Noise | Safety Agency Requirements and EMI/EMS Certified Private Label Marking Available | Modified and Custom Design Available | 2 Years Warranty Turn delay 3000ms max 3S max on the condition that input volotage 230V, full load. 5ms min@AC nominal input@output full load Transient response (dv,tmax) Directive EU 2019/1782 0.6V dv max At AC nominal input loading from 20%load to 80% load 10ms tmax Dynamic rise time 10 us max,duty 40ms max,Dynamic load step is slew rate of 0.5A/us Ambient temp: 35C+-3%; 80% load; input voltage 230V; 2 hours. Dielectric Strength (Hi-pot) Power consumption 0.1W max. At AC nominal input@output min load 500,000 Calculated Hours at 25ºC, by Telcordia SR -332 Cable Length 1830mm (6 feet) standard cable or as required PLD (power line disturbance) Line power surge | Line voltage SAG-more info on request Cooling method Natural Convection Cooling Housing material Temperature coefficient: INPUT Voltage 1A rms@AC low line input and DC output full load Inrush Surge Current (cold start) 60A max@power supply cold start, ambient temperature 25°C @100Vac/240Vac nominal AC input leakage current HI-POT B / IEC 320 2pin primary to secondary 4000Vdc 10mA 1min Operating: 0~40℃ / Storage: -20%~85%RH non condensing Operating: 8%~90%RH / Storage: 5%~95% RH non condensing Over current/ Short protection The power supply will self-protect any output to ground, And auto recovery when abnormal circuit faults remove. An output short circuit is defined as any output impedance of less than 0.1 ohms. Over Voltage The power supply will not be auto recovered when faults remove 110%-150%. (Voltage limit) Input protection 2A /250V Fuse. The power supply shall be protected against power line surges and any abnormal condition The power supply is provided with no load operation to prevent the power supply and system from damage. Protection class WEIGHT NW: 116-133g/pc based on the model Box cca 12kg based on the model
Open the catalog to page 1Wall mount Mechanical case specification: Mechanical specification (country housing): Europe type (W2E) Cable specification: 1185#20*1C + shield / 6FT (1830mm)
Open the catalog to page 2All Sunny catalogs and technical brochures
-
SYS1575-9012-M3
2 Pages
-
ATS 065T-P480
2 Pages
-
SYS1548-5012-T3
2 Pages
-
SYS1548-5012-T2
2 Pages
-
SYS1546-3612-T3
2 Pages
-
SYS1546-3612-T2
2 Pages
-
SYS1588-2709-T2
2 Pages
-
SYS1319-3015-T3
2 Pages
-
SYS1544-2412-T3
2 Pages
-
SYS1544-2412-T2
2 Pages
-
SYS1001-1212-T2
2 Pages
-
SYS1001-0612-T2
2 Pages
-
SYS1541-1505
2 Pages
-
SYS1888-1505
2 Pages
-
SYS1530-1215-W2E
2 Pages
-
SYS1529-1205
2 Pages
-
SYS1381N-1205-W2E
2 Pages
-
SYS1561-1105
2 Pages
-
SYS1121-Wxx
2 Pages
-
SYS1121-Wxx series
2 Pages
-
SYS1638-Wxx series
2 Pages
-
SYS1001-Wxx series
2 Pages
-
SYS1052-W2E series
2 Pages
-
SYS1001-W2E series
2 Pages