Specifications:
Country of Origin: China
Operating Temperature: 0~40°C
Dimensions: 73.8 × 44.3 × 28.8 mm
Certified AC Plugs: EU, UK, USA/Japan/Taiwan, Australia, China, Korea
Efficiency Level: VI
Power Range: 5W~6W

Model Specifications:
  • SYS1001-0505-Wxx*: 5V, 0~1.0A, 5W, 150mV ripple/noise, 2.1x5.5x11mm connector
  • SYS1001-0608-Wxx*: 7.5V, 0~0.8A, 6W, 150mV ripple/noise, 2.1x5.5x11mm connector
  • SYS1001-0609-Wxx*: 9V, 0~0.66A, 6W, 150mV ripple/noise, 2.1x5.5x11mm connector
  • SYS1001-0612-Wxx*: 12V, 0~0.5A, 6W, 150mV ripple/noise, 2.1x5.5x11mm connector
  • SYS1001-0615-Wxx*: 15V, 0~0.4A, 6W, 200mV ripple/noise, 2.1x5.5x11mm connector
  • SYS1001-0618-Wxx*: 18V, 0~0.33A, 6W, 200mV ripple/noise, 2.1x5.5x11mm connector
  • SYS1001-0624-Wxx*: 24V, 0~0.25A, 6W, 240mV ripple/noise, 2.1x5.5x11mm connector

Features:
Certified plugs for various regions, regulated output with low ripple noise, safety agency requirements, and EMI/EMS certified.

Output Specifications:
Turn delay: 3000ms max, Hold up time: 8ms min, Efficiency: >72% at 115V/60Hz, 230V/50Hz, Transient response: 0.4V dv max, Power output limit: 6W, Burn-in limit: Full load 2 hours, Power consumption: 0.1W max.

Input Specifications:
Voltage: 90~264VAC, Frequency: 47~63Hz, Current: 0.5A rms, Inrush Surge Current: 30/40A max, Leakage current: 0.25mA max.

Protection:
Over current/short protection with auto recovery, over voltage protection, input protection with fuse, no load protection, Protection class II.

Compliance and Safety:
CE, EMC 2014/30/EU, LVD 2014/35/EU, EN 60950-1, EN 62368-1, Safety certifications include cTUVus, FCC, GS, CE, CB, RCM, SAA, PSE, EAC, LVD, UKCA.

Other Specifications:
Dielectric Strength: 3000VAC, M.T.B.F: 500,000 hours, Cable Length: 1370mm, Cooling method: Natural Convection, Housing material: PC + ABS, Temperature coefficient: < ±0.5% / °C.

Environmental Conditions:
Operating Temperature: 0~40°C, Storage Temperature: -20~85°C, Operating Humidity: 8%~90% RH, Storage Humidity: 5%~95% RH non-condensing.

Weight and Packing:
Net Weight: 80g/pc + plug, Gross Weight: 95g/pc + plug, Packing: 100 pcs/box.

Mechanical and Cable Specifications:
Various plug types for different regions, standard cable length, and wall mount design.
See more

Catalog excerpts

SYS1001-Wxx series-1

Wall mount GREEN MODE Country of Origin : Operating Temperature : EU, UK, USA/Japan/Taiwan, Aus, China, Korea Approvals / Marks : Features: Certified plugs Wxx = W2E - Europe | W3U - England | W2 - USA, Canada, Japan,Taiwan | W2A - Australia | W2C - China | W2K - Korea Output connector: standard: 2.1 x 5.5 x 11mm or customer requirement | Regulated Output With Low Ripple Noise | Safety Agency Requirements and EMI/EMS Certified Turn delay 3000ms max@AC low line input@output full load 8ms min@AC nominal input@output full load Efficiency (Normal) >72%@115v/60HZ,230V/50HZ input &Full load Transient response (dv,tmax) 0.4V dv max At AC nominal input loading from 20%load to 80% 16ms tmax Dynamic rise time 10 us max,duty 40ms max,Dynamic load step is slew rate of 0.5A/us Power out.Limit Full load 2 Hours Dielectric Strength (Hi-pot) Power consumption 0.1W max. At AC nominal input@output min load 500,000 Calculated Hours at 25ºC, by Telcordia SR-332 Cable Length 1370mm (4.5 feet) standard cable or as required PLD (power line disturbance) Line power surge | Line voltage SAG-more info on request Cooling method Natural Convection Cooling Housing material Temperature coefficient: INPUT Voltage 0.5A rms@AC low line input and DC output full load Inrush Surge Current (cold start) 30/40A max@power supply cold start,ambient temperature 25°C @115Vac/230Vac nominal AC input leakage current Operating: 8%~90%RH / Storage: 5%~95% RH non condensing Over current/ Short protection The power supply will be auto recovered when over current or short circuit faults remove (fold back). Is defined as any output impedance of less than 0.1Ω.The power supply will be auto Over Voltage The power supply will not be auto recovered when faults remove Input protection F1 1A/250V Fuse The power supply shall be protected against The power supply is provided with no load operation to prevent Protection class

 Open the catalog to page 1
SYS1001-Wxx series-2

Wall mount Mechanical case specification: Mechanical specification (country housing): US / Japan type (W2) Cable specification:

 Open the catalog to page 2

All Sunny catalogs and technical brochures

  1. ATS 065T-P480

    2  Pages

  2. SYS1541-1505

    2  Pages

  3. SYS1888-1505

    2  Pages

  4. SYS1529-1205

    2  Pages

  5. SYS1561-1105

    2  Pages

  6. SYS1121-Wxx

    2  Pages

*Prices are pre-tax. They exclude delivery charges and customs duties and do not include additional charges for installation or activation options. Prices are indicative only and may vary by country, with changes to the cost of raw materials and exchange rates.