Specifications:
Country of Origin: China
Operating Temperature: 0~40°C
Dimensions: 93 x 50 x 33 mm
Efficiency Level (ErP): VI
Power Output: 5W~6W
Model Series: Desktop SYS1001-T2

Electrical Characteristics:
Output Turn Delay: 3000ms max at AC low line input and full load
Hold Up Time: 8ms min at AC nominal input and full load
Efficiency: >72% at 115V/60Hz, 230V/50Hz input and full load
Transient Response: 0.4V dv max, 16ms tmax, dynamic rise time 10us max
Power Output Limit: 6W
Burn-in Limit: Full load for 2 hours
Power Consumption: 0.1W max at AC nominal input and minimum load

Input Specifications:
Voltage: 90~264VAC
Frequency: 47~63Hz
Current: 0.5A rms at AC low line input and DC output full load
Inrush Surge Current: 30/40A max at cold start, 25°C
Leakage Current: 0.25mA max

Protection Features:
Over Current/Short Protection: Auto recovery upon fault removal
Over Voltage: No auto recovery
Input Protection: F1:1A 250V Fuse
No Load Protection: Provided
Protection Class: II
Compliance: CE, EMC 2014/30/EU, LVD 2014/35/EU, EN 60950-1, EN 62368-1

Safety and Certifications:
Certifications: cTUVus, FCC, GS, CE, CB, RCM, SAA, PSE, EAC, UKCA

Other Features:
Dielectric Strength: I/P-O/P: 3000VAC
MTBF: 500,000 hours at 25°C
Cable Length: 1370mm standard or as required
Cooling Method: Natural Convection
Housing Material: PC + ABS
Temperature Coefficient: < ±0.5% / °C

Environmental Conditions:
Operating Temperature: 0~40°C
Storage Temperature: -20~85°C
Operating Humidity: 8%~90% RH
Storage Humidity: 5%~95% RH non-condensing

Weight and Packaging:
Net Weight: 98g/pc
Gross Weight: 115g/pc
Packing: 100 pcs/box

Model Specifications:
  • SYS1001-0505-T2: 5V, 0~1.0A, 5W, 150mV ripple/noise
  • SYS1001-0608-T2: 7.5V, 0~0.8A, 6W, 150mV ripple/noise
  • SYS1001-0609-T2: 9V, 0~0.66A, 6W, 150mV ripple/noise
  • SYS1001-0612-T2: 12V, 0~0.5A, 6W, 150mV ripple/noise
  • SYS1001-0615-T2: 15V, 0~0.4A, 6W, 200mV ripple/noise
  • SYS1001-0618-T2: 18V, 0~0.33A, 6W, 200mV ripple/noise
  • SYS1001-0624-T2: 24V, 0~0.25A, 6W, 240mV ripple/noise

Features:
Available in C7 (T2) inlet version, standard output connector 2.1 x 5.5 x 11mm, regulated output with low ripple noise, safety agency requirements and EMI/EMS certified, private label marking available, modified and custom design available, 2 years warranty.

For more information, visit www.sunny-euro.com.
See more

Catalog excerpts

SYS1001-0612-T2-1

GREEN MODE Country of Origin : Operating Temperature : Features: Available in inlet version: C7 (T2) Output connector: standard: 2.1 x 5.5 x 11mm or customer requirement | Regulated Output With Low Ripple Noise | Safety Agency Requirements and EMI/EMS Certified Private Label Marking Available | Modified and Custom Design Available | 2 Years Warranty Turn delay 3000ms max@AC low line input@output full load 8ms min@AC nominal input@output full load Efficiency (Normal) >72%@115v/60HZ,230V/50HZ input &Full load Transient response (dv,tmax) Power out.Limit 0.4V dv max At AC nominal input loading from 20%load to 80% 16ms tmax Dynamic rise time 10 us max,duty 40ms max,Dynamic load step is slew rate of 0.5A/us OTHERS Dielectric Strength (Hi-pot) Power consumption 0.1W max. At AC nominal input@output min load 500,000 Calculated Hours at 25ºC, by Telcordia SR-332 1370mm (4.5 feet) standard cable or as required Full load 2 Hours Cable Length Line power surge | Line voltage SAG-more info on request 0.5A rms@AC low line input and DC output full load Cooling method Natural Convection Cooling Inrush Surge Current (cold start) 30/40A max@power supply cold start,ambient temperature 25°C @115Vac/230Vac nominal AC input Housing material leakage current Temperature coefficient: Over current/ Short protection The power supply will be auto recovered when over current or short circuit faults remove (fold back). Is defined as any output impedance of less than 0.1Ω.The power supply will be auto recovered when short circuit faults remove Over Voltage The power supply will not be auto recovered when faults remove Input protection F1:1A 250V Fuse The power supply shall be protected against The power supply is provided with no load operation to prevent Protection class Operating: 8%~90%RH / Storage: 5%~95% RH non condensing

 Open the catalog to page 1
SYS1001-0612-T2-2

Mechanical case specification: Cable specification:

 Open the catalog to page 2

All Sunny catalogs and technical brochures

  1. ATS 065T-P480

    2  Pages

  2. SYS1541-1505

    2  Pages

  3. SYS1888-1505

    2  Pages

  4. SYS1529-1205

    2  Pages

  5. SYS1561-1105

    2  Pages

  6. SYS1121-Wxx

    2  Pages

*Prices are pre-tax. They exclude delivery charges and customs duties and do not include additional charges for installation or activation options. Prices are indicative only and may vary by country, with changes to the cost of raw materials and exchange rates.