Material
The primary material used for the Sun Ballast system is concrete, chosen for its durability and ability to withstand various climatic conditions.

Application
This system is suitable for any type of flat roof with a maximum slope of 5 degrees, including those on beaten ground with inert material or pavements.

Inclination Angle
The system is designed for an inclination angle of 10 degrees.

Quantity and Weight
  • Each pallet contains 10 pieces.
  • Each ballast weighs 60 kg.
  • The total pallet weight is 600 kg.

Pallet Dimensions
The dimensions of the pallet are 70 cm x 98 cm with a height of 58 cm.

Module Positioning
Modules can be positioned either horizontally or vertically.

Vertical Panel Laying
For vertical panel installation, a minimum distance of 60 cm is recommended between module rows.

Horizontal Panel Laying
For horizontal panel installation, the same minimum distance of 60 cm between module rows is recommended.

System Details and Recommendations
  • Use a torque of 12 - 14 Nm for M8 bolts in stainless steel.
  • Avoid using impulse screwdrivers.
  • Consult the panel manufacturer's assembly instructions.
  • Follow Sun Ballast's assembly instructions.
  • All dimensions are expressed in centimeters.
See more

Catalog excerpts

BALLAST 10°.V ART. 23010.V-1

Ideal support for Photovoltaic modules on a flat roof The main material of SUN BALLAST is concrete, which allows a low wear over time and the ability to withstand even the most intense perturbations and different climatic conditions Any type of flat roof with a maximum slope of 5 º on the ground, on beaten ground with inert material or pavements INCLINATION ANGLE BALLAST WEIGHT PALLET DIMENSIONS MODULE POSITIONING Horizontal / Vertical PALLET WEIGHT Exemplary images may be subject to minor modifications

 Open the catalog to page 1
BALLAST 10°.V ART. 23010.V-2

Ideal support for Photovoltaic modules on a flat roof SYSTEM DETAILS HORIZONTAL PANEL LAYING Side view Minimum distance recommended between module row 60 cm VERTICAL PANEL LAYING Side view Minimum distance recommended between module row 60 cm 20 • The torque applied shall refer to the mechanical standard conforming to the bolt in use; with M8 bolts in stainless steel use a torque of 12 - 14 Nm • Avoid screwdrivers impulse • It’s recommended to consult the information indicated in the assembly instructions of the panel manufacturer • Always follow Sun Ballast assembly instructions. • The dimensions...

 Open the catalog to page 2

Archived catalogs

  1. PRODUCT CATALOG

    64  Pages

*Prices are pre-tax. They exclude delivery charges and customs duties and do not include additional charges for installation or activation options. Prices are indicative only and may vary by country, with changes to the cost of raw materials and exchange rates.