BALLAST 0°.K ART. 23000.K

BALLAST 0°.K ART. 23000.K

BALLAST 0°.K ART. 23000.K

Product catalog summary
Material Specifications
The primary material used for the Sun Ballast system is concrete, chosen for its durability and ability to withstand various climatic conditions.

Application
The system is suitable for any type of flat roof with a maximum slope of 5 degrees, including those on beaten ground with inert material or pavements.

Inclination Angle
The system is designed for a 0° inclination angle.

Quantity and Weight
  • Each pallet contains 18 pieces.
  • Each ballast weighs 30 kg.
  • Pallet dimensions are 90 cm x 98 cm with a height of 35 cm.
  • Total pallet weight is 540 kg.

Module Positioning
Modules can be positioned either horizontally or vertically.

Vertical Panel Laying
Minimum recommended distance between module rows is 0 cm.

Horizontal Panel Laying
Minimum recommended distance between module rows is 0 cm.

System Details and Recommendations
  • Use a torque of 12 - 14 Nm for M8 bolts in stainless steel.
  • Avoid using impulse screwdrivers.
  • Consult the panel manufacturer's assembly instructions.
  • Follow Sun Ballast's assembly instructions.
  • All dimensions are expressed in centimeters.
See more

Catalog excerpts

BALLAST 0°.K ART. 23000.K-1

Ideal support for Photovoltaic modules on a flat roof The main material of SUN BALLAST is concrete, which allows a low wear over time and the ability to withstand even the most intense perturbations and different climatic conditions Any type of flat roof with a maximum slope of 5 º on the ground, on beaten ground with inert material or pavements INCLINATION ANGLE BALLAST WEIGHT PALLET DIMENSIONS MODULE POSITIONING Horizontal / Vertical PALLET WEIGHT Exemplary images may be subject to minor modifications

 Open the catalog to page 1
BALLAST 0°.K ART. 23000.K-2

Ideal support for Photovoltaic modules on a flat roof SYSTEM DETAILS VERTICAL PANEL LAYING Side view Minimum distance recommended between module rows 0 cm HORIZONTAL PANEL LAYING Side view Minimum distance recommended between module rows 0 cm • The torque applied shall refer to the mechanical standard conforming to the bolt in use; with M8 bolts in stainless steel use a torque of 12 - 14 Nm • Avoid screwdrivers impulse • It’s recommended to consult the information indicated in the assembly instructions of the panel manufacturer • Always follow Sun Ballast assembly instructions. • The dimensions...

 Open the catalog to page 2

Archived catalogs

  1. PRODUCT CATALOG

    64  Pages

*Prices are pre-tax. They exclude delivery charges and customs duties and do not include additional charges for installation or activation options. Prices are indicative only and may vary by country, with changes to the cost of raw materials and exchange rates.