Introduction
This document provides specifications and guidelines for the installation of photovoltaic modules on flat roofs using the Sun Ballast system. It includes details on ballast types, material specifications, and installation procedures.

Ballast Specifications
  • Front Ballast (Art. 23005.CF): Weighs 20 kg, pallet dimensions are 70 cm x 98 cm x 85 cm, with 32 pieces per pallet and a total pallet weight of 640 kg.
  • Central Ballast (Art. 23005.CR): Weighs 16 kg, pallet dimensions are 88 cm x 65 cm x 57 cm, with 36 pieces per pallet and a total pallet weight of 576 kg.
  • Terminal Ballast (Art. 23005.CRT): Weighs 35 kg, pallet dimensions are 90 cm x 98 cm x 45 cm, with 16 pieces per pallet and a total pallet weight of 560 kg.

Material and Application
The Sun Ballast system is primarily made of concrete, providing durability and resistance to various climatic conditions. It is suitable for any flat roof with a maximum slope of 5º, including ground with inert material or pavements.

System Details
  • Inclination Angle: 5°
  • Distance Between Modules: Fixed
  • Module Positioning: Horizontal

Installation Guidelines
  • Use a torque of 12 - 14 Nm for M8 stainless steel bolts.
  • Avoid using impulse screwdrivers.
  • Consult the panel manufacturer's assembly instructions and always follow Sun Ballast's instructions.
  • Minimum recommended configuration is 5 rows of 5 panels.
  • For panels with a short side greater than 1m, consult the technical department.

Additional Information
For further details, visit the Sun Ballast website at www.sunballast.it.
See more

Catalog excerpts

5° CONNECT SYSTEM ART. 23005.CF/.CR/.CRT-1

Ideal support for Photovoltaic modules on a flat roof The main material of SUN BALLAST is concrete, which allows a low wear over time and the ability to withstand even the most intense perturbations and different climatic conditions Any type of flat roof with a maximum slope of 5º on the ground, on beaten ground with inert material or pavements Inclination angle Module positioning Distance between modules Fixed distance Front Ballast Art. 23005.CF Ballast weight Pallet dimensions Pallet weight Central Ballas Art. 23005.CR Ballast weight Pallet dimensions Pallet weight Terminal Ballas Art. 23005.CRT Ballast weight Pallet dimensions Pallet weight Exemplary images may be subject to minor modifications

 Open the catalog to page 1
5° CONNECT SYSTEM ART. 23005.CF/.CR/.CRT-2

Ideal support for Photovoltaic modules on a flat roof SYSTEM DETAILS HORIZONTAL PANEL LAYING Side view 45 • The torque applied shall refer to the mechanical standard conforming to the bolt in use; with M8 bolts in stainless steel use a torque of 12 - 14 Nm • Avoid screwdrivers impulse • It’s recommended to consult the information indicated in the assembly instructions of the panel manufacturer • Always follow Sun Ballast assembly instructions. • The dimensions shown in the figure are all expressed in centimeters. • Minimum recommended configuration: 5 rows of 5 panels. • For short side panel...

 Open the catalog to page 2

Archived catalogs

  1. PRODUCT CATALOG

    64  Pages

*Prices are pre-tax. They exclude delivery charges and customs duties and do not include additional charges for installation or activation options. Prices are indicative only and may vary by country, with changes to the cost of raw materials and exchange rates.