Product catalog summary
Nomenclature and Model List
The document details the nomenclature and model list for ALTAX NEO gearmotors, emphasizing the importance of specifying correct nomenclature, voltage, and frequency when ordering. Models include outdoor, dustproof, increased safety, waterproof, and overseas standards. Detailed tables for three-phase, single-phase, and inverter motors highlight motor capacities and reduction ratios.
Standard Specifications
ALTAX NEO gearmotors are available in three-phase and single-phase configurations, with capacities from 90W to 2.2kW. They feature IP44 enclosures, continuous time ratings, and JIS compliance, designed for indoor use with specific environmental conditions.
Model Selection
The selection process involves determining equivalent transmission torque, reduction ratio, and checking radial loads. Formulas and tables assist in selecting the appropriate model based on load factors, radial loads, and starting frequencies.
Load and Application Considerations
Designed for up to 10 hours of operation per day with uniform loads, the document categorizes load conditions into uniform, light shock, and heavy shock loads, providing load factors for each.
Thermal Capacity and Inertia
Tables for calculating the motor's allowable thermal capacity and moment of inertia are included, with steps to calculate the product of C and Z within allowable limits.
Traction Model Notes
Models with 'R' or 'S' suffixes are traction-drive types. Consultation is advised for applications with severe impact loads or requiring high-precision positioning.
Dimension Tables
Detailed dimension tables are provided for flange and foot mount types, specifying output speeds, torque, and allowable radial loads for various models.
Motor Specifications and Variants
Specifications for various motor types, including single-phase and three-phase motors, with and without brakes, are detailed. It covers different power classes and outlines motor frame sizes, rated current, maximum torque, starting torque, starting current, and speed for each configuration.
Gearmotor Specifications
Details specifications for inverter-compatible motors, including reduction ratio ranges for indoor, outdoor, and light dust-proof types, specifying motor frame sizes and reduction ratios for different power outputs.
Brake Characteristics
Outlines characteristics of electromagnetic brakes for both single-phase and three-phase motors, including standard torque, moment of inertia, total braking energy, motion delay time, and brake current.
Rectifier and Circuit Information
Details on rectifier output voltages for brakes and differences between standard and quick braking circuits, explaining how quick braking circuits can shorten braking time.
Connection Diagrams
Includes connection diagrams for single-phase and three-phase motors, highlighting necessary components such as electromagnetic contactors and overload relays.
Paint Properties and Color
Specifies standard paint properties and colors for motors, including weather resistance, oil-proof, and heat resistance characteristics.
Warranty and Safety Precautions
Outlines the warranty period, conditions, and exclusions, emphasizing adherence to industrial safety and health laws.
Introduction
Guidelines and recommendations for installation and maintenance of machinery in environments with specific safety and operational requirements.
Maintenance Manual
Emphasizes the importance of reading the maintenance manual thoroughly before using any equipment.
Product Selection
Recommends choosing a product suitable for the operating environment and intended application for optimal performance and safety.
Protective Equipment
Highlights the necessity of installing protective equipment for machinery used in passenger transportation.
Flameproof Motors
Advises using flameproof type motors in explosive environments to prevent accidents.
Inverter Use with 400V Motors
Recommends using a high carrier frequency inverter with higher input voltage or insulation pressure for 400V class standard motors.
Oil and Grease Leakage Prevention
Suggests installing an oil pan or similar devices for applications sensitive to oil or grease.
See more

Catalog excerpts

ALTAX NEO-4

Nomenclature / List of Models Nomenclature Make sure to specify the applicable nomenclature, voltage, and frequency when ordering or inquiring. Also specify when the required model is: outdoor type, light dust proof type, increased safety type (eG3), water proof type (IP65), terminal box/terminal platform type or type for overseas standards. Brake Blank Without brake B With brake Slow-Speed Shaft Direction N Universal direction Suffix Blank Three-phase motor CA Capacitor-run single-phase motor Mounting Style V Flange H Foot Capacitor-start / capacitor-run single-phase motor Reversible single-phase...

 Open the catalog to page 4
ALTAX NEO-5

Standard Specification Standard Specifications ALTAX NEO Three-Phase / Single-Phase Gearmotor Type Item Capacity Range Three-Phase Motor Power Source Insulation Standard Specification Standard Specification with Built-in Brake Note: 90W - 2.2kW, 4-pole Note: 90W - 2.2kW, 4-pole RB, FB brake (non-asbestos lining) IP44 (indoor), totally-enclosed fan-cooled type IP44 (indoor), totally-enclosed fan-cooled type (The 90W and 0.1kW models are the totally-closed self- (The 90W and 0.1kW models are the totally-closed selfcooled type) cooled type) Three-rated power sources Three-rated power source 200V...

 Open the catalog to page 5
ALTAX NEO-6

Model Selection Model Selection Determine Model Determine Equivalent Transmission Torque Te Actual transmission torque T Determine the gearmotor’s load factor T : Actual transmission torque at the gearmotor’s slow-speed shaft [N m] Determine the equivalent transmission torque Te Te=T x Gearmotor’s load factor [N m] Te: Equivalent transmission torque [N m] Determine the reduction ratio Power frequency x 30 Reduction ratio Output speed Refer to the selection table TOUT: Gearmotor’s output torque [N m] Determine the model (Note) Select the model that satisfies Te TOUT Note: Models with "R" or "S"...

 Open the catalog to page 6
ALTAX NEO-7

Reference for Model Selection ALTAX NEO gearmotor is designed for 10 hours operation per day with uniform load. 1. Gearmotor’s Load Factor Table 1 Daily Duty Load Condition Uniform Load Conveyor (uniform load), pump (centrifugal), food processing machine (rice milling machine, can filling machine), elevator (uniform load), plastic molding machine, agitator (liquid), bar screen Main Applications Light Shock Load Conveyor (heavy duty, not uniformly fed), food processing machine (beet slicer, dough mixer, meat grinder), elevator (heavy load), agitator (liquids & solids, liquids variable density),...

 Open the catalog to page 7
ALTAX NEO-8

Reference for Model Selection Table 6: Motor’s Allowable Thermal Capacity (C x Z) Motor Output [kW] Motor’s Moment of Inertia [kg m2] With Brake With Brake Calculate C x Z by below steps (1)-(3). The value must be less than allowable C x Z listed in Table 6. (1) Calculate C using formula below. JM: Moment of inertia of motor [kg•m2] JL: Total moment of inertia (excluding motor) at motor shaft [kg•m ] GDL2: Total GD2 (excluding motor) at motor shaft [kgf•m2] (2) Calculate Z (number of starting times/hour) (a) Operating period consists of “operation time ta [sec]” and “stop time tb [sec].” Motor...

 Open the catalog to page 8
ALTAX NEO-9

Notes for Selecting a Traction Model Notes for Selecting a Traction Model The models that have “R” or “S” at the end of the frame size (for example, 507R, 5107DR, and 5127DS) are traction-drive models. They are suitable for normal applications, but consult us for confirmation for the following applications: (1) Load and Application Consult us for applications involving particularly severe impact load (crushers, breakers, high-speed cutting machines) or variable load (crank/cam motions). (2) Applications Requiring High-Precision Positioning Actual reduction ratio of traction-drive models fluctuates...

 Open the catalog to page 9
ALTAX NEO-10

Gearmotors, Flange Mount Type (CNVM), Foot Mount Type (CNHM) 90W Three-Phase Motor Reduction Ratio Selection Tables Input Capacity - Frame Size Symbol Output Speed r/min CNVM (Flange Mount) CNHM (Foot Mount) Figure in the bracket ( ) shows the dimension for types with brake. Output motor speed is the representative value at 1450r/min (50Hz) and 1750r/min (60Hz). Refer to page 31 for details. Radial load at slow speed shaft is the value at the middle of the slow speed shaft. Figure in the bracket ( ) shows the dimension for types with brake. Outdoor type, dustproof type with brake, and some type...

 Open the catalog to page 10
ALTAX NEO-11

Gearmotors, Flange Mount Type (CNVM), Foot Mount Type (CNHM) 0.1kW Three-Phase Motor Reduction Ratio Selection Tables Input Capacity - Frame Size Symbol Output Speed r/min CNVM (Flange Mount) CNHM (Foot Mount) Model CNVM01-507R(-B)-Reduction Ratio CNVM01-5067(-B)-Reduction Ratio CNVM01-5077(-B)-Reduction Ratio CNVM01-5087(-B)-Reduction Ratio CNVM01-5097(-B)-Reduction Ratio CNVM01-5097DR(-B)-Reduction Ratio CNVM01-5107DR(-B)-Reduction Ratio CNVM01-5107DA(-B)-Reduction Ratio CNVM01-5127DA(-B)-Reduction Ratio Model CNHM01-507R(-B)-Reduction Ratio CNHM01-5067(-B)-Reduction Ratio CNHM01-5077(-B)-Reduction...

 Open the catalog to page 11
ALTAX NEO-12

Gearmotors, Flange Mount Type (CNVM), Foot Mount Type (CNHM) 0.2kW Three-Phase Motor Reduction Ratio Selection Tables Input Capacity - Frame Size Symbol Output Speed r/min CNVM (Flange Mount) CNHM (Foot Mount) Model CNVM02-507R(-B)-Reduction Ratio CNVM02-506H(-B)-Reduction Ratio CNVM02-5077(-B)-Reduction Ratio CNVM02-5087(-B)-Reduction Ratio CNVM02-5097(-B)-Reduction Ratio CNVM02-5097DR(-B)-Reduction Ratio CNVM02-5107DR(-B)-Reduction Ratio CNVM02-5117DR(-B)-Reduction Ratio CNVM02-5127DA(-B)-Reduction Ratio Model CNHM02-507R(-B)-Reduction Ratio CNHM02-506H(-B)-Reduction Ratio CNHM02-5077(-B)-Reduction...

 Open the catalog to page 12
ALTAX NEO-13

Gearmotors, Flange Mount Type (CNVM), Foot Mount Type (CNHM) 0.25kW Three-Phase Motor Reduction Ratio Selection Tables Input Capacity - Frame Size Symbol Output Speed r/min CNVM (Flange Mount) CNHM (Foot Mount) Model CNVM03-507R(-B)-Reduction Ratio CNVM03-5077(-B)-Reduction Ratio CNVM03-5087(-B)-Reduction Ratio CNVM03-5097(-B)-Reduction Ratio CNVM03-5107(-B)-Reduction Ratio CNVM03-5097DR(-B)-Reduction Ratio CNVM03-5107DR(-B)-Reduction Ratio CNVM03-5117DR(-B)-Reduction Ratio CNVM03-5127DA(-B)-Reduction Ratio Model CHHM03-507R(-B)-Reduction Ratio CHHM03-5077(-B)-Reduction Ratio CHHM03-5087(-B)-Reduction...

 Open the catalog to page 13

All SUMITOMO Drive Technologies America catalogs and technical brochures

  1. Fine Cyclo

    70  Pages

  2. PARAMAX ® 9000

    281  Pages

  3. E CYCLO

    28  Pages

  4. IB P2 Catalog

    36  Pages

  5. IB PK1 Catalog

    70  Pages

  6. IB-P1 Catalog

    94  Pages

Archived catalogs

  1. Servo

    114  Pages

  2. Astero® series

    95  Pages

  3. Hedcon catalog

    23  Pages

  4. SPA Series

    10  Pages

  5. HF430 Catalog

    31  Pages

  6. FINE CYCLO

    2  Pages

  7. Servo PPG

    4  Pages

  8. IB P1 series

    93  Pages

  9. Fine Cyclo®

    22  Pages

*Prices are pre-tax. They exclude delivery charges and customs duties and do not include additional charges for installation or activation options. Prices are indicative only and may vary by country, with changes to the cost of raw materials and exchange rates.