Wastewater TOC Analyzers

Wastewater TOC Analyzers

Wastewater TOC Analyzers

Product catalog summary
Overview
GE Analytical Instruments has developed the Sievers InnovOx Total Organic Carbon (TOC) Analyzers, available in Laboratory and On-Line models, to enhance sample handling and instrument uptime for organic carbon analysis in various sectors. The InnovOx employs Supercritical Water Oxidation (SCWO) for improved reliability and reduced maintenance compared to traditional TOC analyzers.

Features and Benefits
  • Wide Dynamic Operating Range: Measures up to 50,000 ppm.
  • Versatile Measurement Modes: Capable of measuring Total Inorganic Carbon (TIC), Non-Purgeable Organic Carbon (NPOC), Total Carbon (TC), and TOC by difference.
  • Sample Handling Robustness: Utilizes SCWO to handle complex sample matrices like brine and humic acid with high reliability.
  • Easy Operation: Features intuitive touch-screen interfaces and requires no warm-up or stabilization.
  • Low Maintenance: Offers up to six months of calibration stability and minimal operator intervention.
  • Remote Monitoring: Ethernet Web browser interface for remote control and monitoring.

Key Applications
  • Petrochemical
  • Food and Beverage
  • Pharmaceutical
  • Environmental Labs
  • Municipal/Industrial Wastewater
  • Power
  • Pulp and Paper

Technology and Operation
  • Sample Handling and Reagent Mixing: Ensures accuracy by processing large sample volumes with thorough agitation.
  • Supercritical Water Oxidation (SCWO): Achieves efficient oxidation of TOC to CO2, even in challenging conditions.
  • NDIR Detection: Utilizes a stable, nondispersive infrared detector with no moving parts.

Specifications
  • Analysis Modes: NPOC, TOC (TC-IC), TC, IC
  • Dynamic TOC Range: Up to 50,000 ppm
  • TOC Limit of Detection: 0.05 ppm NPOC
  • TOC Accuracy: ±3%
  • TOC Precision: RSD ≤ 1.5%
  • Analysis Time: 2.6 to 8.3 minutes in online mode
  • Calibration Stability: Up to 6 months

Accessories and Options
  • Air Purifier: Removes CO2 from air for use as a compressed gas source.
  • Filter Panel: Filters sample streams and cleans automatically.
  • Fail-Safe Accessory: Detects flow rate issues and consumable needs.
  • GE Autosampler: Handles high-volume applications with up to 120 sample tubes.
See more

Catalog excerpts

Wastewater TOC Analyzers-1

GE Power & Water Water & Process Technologies Fact Sheet Analytical Instruments Sievers InnovOx Laboratory and On-Line TOC Analyzers Overview GE Analytical Instruments designed the Sievers* InnovOx Total Organic Carbon (TOC) Analyzers to provide industryleading sample handling robustness and instrument uptime for process, environmental, and wastewater organic carbon analysis. Available in both Laboratory and On-Line models, the InnovOx uses an innovative Supercritical Water Oxidation technique that offers enhanced reliability, greater ease of use, and lower maintenance than typical combustion or UV persulfate TOC analyzers. L ow Maintenance and Cost of Ownership—Robust by design, the InnovOx requires minimal operator intervention or preventive maintenance, offers up to six months’ calibration stability, and features a solid state nondispersive infrared (NDIR) detector. E thernet Web browser interface (Lab)—Allows users to remotely monitor and control Analyzer operations and results using a Web-based interface via the instrument’s Ethernet port. U ser-configurable alarms and outputs (On-Line)—Notifies user of water system events and enables remote monitoring of analysis results and performance. Features and Benefits W ide Dynamic Operating Range—Measures up to 50,000 parts per million (ppm). V ersatile Measurement Modes—Measures Total Inorganic Carbon (TIC), NPOC, Total Carbon (TC) and TOC by difference (TC-TIC). S ample Handling Robustness—Uses an innovative Supercritical Water Oxidation (SCWO) technique to achieve superior TOC recoveries regardless of organic compounds and particulate impurities in the sample. The InnovOx can handle a wide variety of traditionally difficult sample matrices, including brine, cellulose, and humic acid (see table on page 4) with unprecedented reliability. E asy Operation—The InnovOx On-Line offers preset protocols for easy startup. Both OnLine and Laboratory models have intuitive color touch-screen interfaces, and operate immediately without any necessary heater warm-up or detector stabilization. InnovOx Laboratory TOC Analyzer Web Interface

 Open the catalog to page 1
Wastewater TOC Analyzers-2

InnovOx On-Line TOC Analyzer Touch-Screen Interface InnovOx On-Line TOC Analyzer Touch-Screen Interface Supercritical Water Oxidation (SCWO) Using a patented SCWO technique (see sidebar below), the Sievers InnovOx takes the water sample to a supercritical state by increasing the temperature, and subsequently the pressure, within the reactor. The properties of supercritical water enable an ultra-efficient oxidation of TOC to carbon Chlor-alkali Chemistry Environmental Labs Municipal/Industrial Wastewater Brine and Seawater dioxide, even in the presence of chloride and other inorganic species that...

 Open the catalog to page 2
Wastewater TOC Analyzers-3

InnovOx On-Line Analyzer Details Accessories and Options Air Purifier The Air Purifier removes CO2 from the air so the Analyzer can use house air as the compressed gas source. Filter Panel This accessory filters one sample stream, and it is automatically cleaned by back flushing with compressed air. The Filter Panel is adjustable for various particulate levels. Fail-Safe Accessory Sensors detect when the flow rate of each sample stream stops or consumables need replenishing. IP56 The IP56 configuration protects the Analyzer from water spray and dust that would interfere with its operation. NEMA 4X...

 Open the catalog to page 3
Wastewater TOC Analyzers-4

InnovOx Laboratory Analyzer Details Accessories and Options Air Filter The Air Filter is used to purify ambient air and pressurize it sufficiently for use as sparge and carrier gas. It easily attaches to the back of the Lab model, so the Analyzer can be used in place of external carrier gas cylinders. GE Autosampler For high-volume laboratory applications, the InnovOx can be used with the GE Autosampler. It can handle up to 120 35-mL sample tubes or up to 63 40-mL or 60-mL vials in one protocol. An optional stirring station creates a homogeneous mixture for analysis during the sampling process....

 Open the catalog to page 4

All Suez Water Technology & Solutions catalogs and technical brochures

  1. Tonkaflo

    3  Pages

  2. GenGard

    2  Pages

  3. ZeeWeed 1500

    2  Pages

  4. FoamTrol

    1  Page

  5. Procera

    2  Pages

  6. ED / BPED

    4  Pages

  7. EDR

    3  Pages

  8. BEVPAK series

    3  Pages

  9. PROflex

    5  Pages

  10. PRO E-Cell

    2  Pages

  11. GE BEV Series

    2  Pages

  12. RePAK Series

    2  Pages

  13. DEOX Process

    1  Page

  14. Spectrus

    2  Pages

*Prices are pre-tax. They exclude delivery charges and customs duties and do not include additional charges for installation or activation options. Prices are indicative only and may vary by country, with changes to the cost of raw materials and exchange rates.