IPER Ultra Efficient Pump Overview
The IPER Ultra Efficient Pump is designed for use in desalination reverse osmosis systems, offering significant energy savings. It is capable of producing 1,000 m3/d (264k gpd) of permeate and can reduce energy costs by up to 50% compared to systems without energy recovery.

Key Benefits
  • Highly energy-efficient, reducing operational costs.
  • Pre-engineered system combining flow controls, high-pressure pumping, and energy recovery.
  • No need for additional controls or pressure regulators.
  • Modular design with low inlet pressure requirements.

Features
  • Robust FRP water cylinders and dual-acting pistons for maximum energy transfer.
  • Simple one-button start-up and shut-down controls.
  • Nominal operating power of 100 KW.
  • Skid-mounted master control enclosure.
  • Low cycle rate compared to positive displacement pumps.

Operating Parameters
  • Maximum permeate: 264k gpd (183.5 gpm or 1,000 m3/d).
  • Fixed recovery rate: 35% to 45%.
  • Maximum pressure: 1160 psi (80 bar).
  • Operating temperature range: 40 to 95ºF (4 to 35ºC).
  • Minimum inlet pressure: 15 psi (1.0 bar).

Efficiency Explanation
  • Utilizes efficient Hydraulic Power Unit (HPU) technology.
  • Combines hydraulic energy from high-pressure SWRO reject with HPU energy for consistent flow and pressure.
  • Prevents mixing between raw seawater feed and SWRO reject.
  • Eliminates the need for a secondary boost pump.

Materials of Construction
  • High-pressure piping: SS Duplex 2205.
  • Low-pressure piping: Sch. 80, PVC.
  • High-pressure valves: Super Duplex 2507.
  • Frame: Epoxy painted carbon steel.
  • Water cylinders: FRP.
  • Enclosures: NEMA 4.

Installation and Utility Requirements
  • Inlet and outlet connections: 3.0” to 4.0” Victaulic.
  • Minimum inlet water pressure: 15 psi (1.0 bar).
  • Air pressure: 100 psi (6.9 bar), oil-free.
  • Power supply: 380/460 VAC, 3-phase, 50/60Hz.
  • Control circuit: 120/220 VAC, 1-phase, 50/60Hz.
See more

Catalog excerpts

Integrated Pump and Energy Recovery Pump (IPER)-1

Fact Sheet IPER* Ultra Efficient Pump SWRO Integrated Pump and Energy Recovery 1,000 m3/d (264k gpd) permeate Figure 1: IPER Ultra Efficient Pump IPER Benefits IPER is one of the most energy efficient pumps in the world (Figure 1). Applied to desalination reverse osmosis systems, it can reduce energy costs by 50%.1 Robust FRP water cylinders Dual-acting pistons transfer maximum energy One button start up and shut down controls Pre-engineered pumping system combines flow controls, high pressure pumping and energy recovery into one skid 100 KW Nominal Operating Power Ultra efficient hydraulic power source Skid mounted master control enclosure Proven, reliable hydraulic power source that is scalable and adaptable Extremely low cycle rate compared to positive displacement pumps No additional controls, drives, pressure regulators, or flow balancing required Modular design Low inlet pressure requirement to desalination plants operating with no energy recovery. Efficiency claims based on competitors published motor and pump efficiencies. Find a contact near you by visiting www.gewater.com and clicking on “Contact Us”. * Trademark of General Electric Company; may be registered in one or more countries. ©2014, General Electric Company. All rights reserved. FSppIPER_EN Oct-14

 Open the catalog to page 1
Integrated Pump and Energy Recovery Pump (IPER)-2

Uses the hydraulic energy from the high pressure SWRO reject, combined with energy from the HPU, to deliver constant flow and pressure to membranes Employs piston as a barrier so there is no appreciable mixing between raw seawater feed and SWRO reject Raw Seawater Water Feed In Cylinder Feed Out Leverages highly efficient and reliable Hydraulic Power Unit (HPU) technology (Fig 2) Eliminates secondary boost pump required by other energy recovery devices Figure 2: IPER operational flow diagram Operating Parameters Maximum SWRO Permeate Fixed Recovery Maximum Pressure Minimum Inlet Pressure High...

 Open the catalog to page 2

All Suez Water Technology & Solutions catalogs and technical brochures

  1. Tonkaflo

    3  Pages

  2. GenGard

    2  Pages

  3. ZeeWeed 1500

    2  Pages

  4. FoamTrol

    1  Page

  5. Procera

    2  Pages

  6. ED / BPED

    4  Pages

  7. EDR

    3  Pages

  8. BEVPAK series

    3  Pages

  9. PROflex

    5  Pages

  10. PRO E-Cell

    2  Pages

  11. GE BEV Series

    2  Pages

  12. RePAK Series

    2  Pages

  13. DEOX Process

    1  Page

  14. Spectrus

    2  Pages

*Prices are pre-tax. They exclude delivery charges and customs duties and do not include additional charges for installation or activation options. Prices are indicative only and may vary by country, with changes to the cost of raw materials and exchange rates.