Overview of GE 2020 EDR Systems
The GE 2020 Electrodialysis Reversal (EDR) system is a reliable desalination technology used in various industrial and public infrastructure applications. It features carbon electrodes, high water recovery up to 94%, salt removal between 50% to 95%, and self-cleaning through polarity reversal. The system is tolerant to free chlorine and moderate suspended solids, and allows for adjustable product water performance without blending.
Key Benefits
  • Efficient use of water resources
  • Low pretreatment and chemical consumption costs
  • Long membrane life of over 10 years
  • Resilience to suboptimal feed water quality
Standard Design and Components
  • MK-IV-2 EDR stacks with GE Carbon Electrodes
  • Cartridge filter and concentrate recirculation pump with VFD
  • GE Fanuc Micro PLC and 12” color Quick Panel HMI
  • Comprehensive operation and maintenance manual
Instrumentation and Operating Parameters
  • Flow and pressure transmitters at various outlets
  • Conductivity measurement at inlet and product outlet
  • Operating temperature range: 40 to 100ºF (4 to 38ºC)
  • Maximum feed pressure: 50 psi
  • Input voltage: 480VAC/3/60Hz
Feed Water Requirements
  • Typical Feed TDS: 100 to 3,000 ppm
  • Maximum Feed TDS: 12,000 ppm
  • pH range: 2 to 10
  • SDI: 10 (5 min. test)
  • Turbidity: < 0.5 NTU
Material and Construction
  • Welded frame made of painted carbon steel
  • Sch. 80 PVC piping for dilute and concentrate streams
  • ANSI flanges and NEMA-rated rectifier and control panel
Quality Assurance
  • UL Certification
  • ISO 9001:2000 Facility
Model Specifications
The document provides detailed specifications for various models (2020-2L-2S, 2020-2L-3S, 2020-4L-2S, 2020-4L-3S, 2020-6L-2S, 2020-6L-3S, 2020-8L-2S, 2020-8L-3S) including flow rates, number of stacks, lines, stages, dimensions, piping sizes, electrical requirements, and power consumption. Performance is dependent on inlet feed water quality and temperature, requiring a Watsys projection for proper system design and performance guarantee.
See more

Catalog excerpts

Electrodialysis Reversal (EDR)-1

Fact Sheet GE 2020 EDR Systems Electrodialysis Reversal Technology The GE 2020 Electrodialysis Reversal (EDR) product is a proven and reliable desalination technology that has been in service in a variety of industrial and public infrastructure applications. Use of Carbon Electrodes results in no gas produced and no separate electrode stream required. High Water Recovery, up to 94% Salt Removal of 50 to 95% Polarity Reversal self-cleaning with electricity Free chlorine tolerance Tolerance to moderate suspended solids Adjustable product water performance without blending Ability to disassemble stacks for inspection Silica tolerance Efficient use of scarce water resources Low pretreatment requirements and costs Low chemical consumption costs Long membrane life, typically 10+ years Strong ability to recover from less than ideal feed water quality Standard Design and Scope of Supply MK-IV-2 EDR stacks with GE Carbon Electrodes Cartridge filter Concentrate Recirculation pump with VFD GE Fanuc Micro PLC & 12” (30 cm) color Quick Panel HMI Full Owners Operation & Maintenance Manual, Factory Acceptance Test results and Stack Performance Test results

 Open the catalog to page 1
Electrodialysis Reversal (EDR)-2

EDR 2020 2 & 4 Line Standard Systems MODEL Flow Rates 280 gpm 260 gpm 560 gpm 520 gpm 63.6 m3/h 59.1 m3/h 127.2 m3/h 118.2 m3/h 165 to 325 gpm 165 to 270 gpm 325 to 655 gpm 325 to 545 gpm Product Flow Range 37.5 to 73.8 m3/h 37.5 to 61.3 m3/h 73.8 to 148.8 m3/h 73.8 to 123.8 m3/h Concentrate Outlet Flow Depends on recovery and product 2.2 gpm 2.5 gpm 4.3 gpm 5.0 gpm Electrode Outlet Flow 8.3 lpm 9.5 lpm 16.3 lpm 19 lpm General Information Number of Stacks 4 6 8 12 Number of Lines 2 2 4 4 Number of Stages 2 3 2 3 Type of Stack MK-IV-2 MK-IV-2 MK-IV-2 MK-IV-2 Dimensions System Dimensions 90” x...

 Open the catalog to page 2
Electrodialysis Reversal (EDR)-3

EDR 2020 6 & 8 Line Standard Systems MODEL Flow Rates 840 gpm 780 gpm 1120 gpm 1040 gpm 190.8 m3/h 177.2 m3/h 254.4 m3/h 236.2 m3/h 485 to 985 gpm 485 to 820 gpm 645 to 1315 gpm 645 to 1090 gpm Product Flow Range 110.2 to 223.7 m3/h 110.2 to 186.2 m3/h 146.5 to 298.7 m3/h 146.5 to 247.6 m3/h Concentrate Outlet Flow Depends on recovery and product flow rate 6.5 gpm 7.5 gpm 8.7 gpm 10 gpm Electrode Outlet Flow 25 lpm 28 lpm 33 lpm 38 lpm General Information Number of Stacks 12 18 16 24 Number of Lines 6 6 8 8 Number of Stages 2 3 2 3 Type of Stack MK-IV-2 MK-IV-2 MK-IV-2 MK-IV-2 Dimensions System...

 Open the catalog to page 3

All Suez Water Technology & Solutions catalogs and technical brochures

  1. Tonkaflo

    3  Pages

  2. GenGard

    2  Pages

  3. ZeeWeed 1500

    2  Pages

  4. FoamTrol

    1  Page

  5. Procera

    2  Pages

  6. ED / BPED

    4  Pages

  7. EDR

    3  Pages

  8. BEVPAK series

    3  Pages

  9. PROflex

    5  Pages

  10. PRO E-Cell

    2  Pages

  11. GE BEV Series

    2  Pages

  12. RePAK Series

    2  Pages

  13. DEOX Process

    1  Page

  14. Spectrus

    2  Pages

*Prices are pre-tax. They exclude delivery charges and customs duties and do not include additional charges for installation or activation options. Prices are indicative only and may vary by country, with changes to the cost of raw materials and exchange rates.