Overview: The document provides technical specifications and details for pressure switches models 0159, 0175, 0161, and 0162. These switches are designed for various applications with features like adjustable switching pressure, high overpressure safety, and compliance with RoHSII standards.
Specifications:
  • Temperature Resistance: Varies by sealing material, with NBR ranging from -40°C to +100°C, EPDM from -30°C to +120°C, and FKM from -5°C to +120°C.
  • Switching Frequency: 200 cycles per minute.
  • Mechanical Life Expectancy: 1,000,000 cycles for diaphragm pressure switches up to 50 bar.
  • Pressure Rise Rate: ≤ 1,000 bar/s.
  • Hysteresis: Approximately 10-30%, adjustable for certain models.
  • Vibration and Shock Resistance: Compliant with DIN EN 60068-2-6 and DIN EN 60068-2-27 standards.
  • Housing Material: Aluminium.
  • Protection Class: IP65 with socket device, otherwise IP00.
Electrical Values:
  • Rated Working Voltage: Up to 250 V AC and various DC voltages.
  • Rated Insulation Voltage: 300 V.
  • Rated Impulse Withstand Voltage: 2.5 kV.
  • Conventional Thermal Current: 6 A.
  • Switching Overvoltage: Less than 2.5 kV.
Models and Features:
  • Model 0159: Diaphragm and piston pressure switches with adjustable switching points and overpressure safety up to 600 bar.
  • Model 0161/0162: Similar features with factory-adjustable hysteresis and socket device compatibility.
  • Model 0175: Designed for low pressure with high accuracy, featuring overpressure safety up to 25 bar.
Installation and Adjustment: The set point can be adjusted by loosening the locknut and turning the set screw. Clockwise adjustments increase the switching pressure.
Applications: Suitable for use with hydraulic/machine oil, air, nitrogen, brake fluid, water, hydrogen, oxygen, acetylene, and various hydraulic fluids depending on the seal material.
See more

Catalog excerpts

M.7 Pressure switches 30 A/F-1

Changeover with silver contacts Attachment options for wall fitting and block style enable clearly structured, accessible, easy-maintenance installation Switching pressure can be adjusted easily by user High overpressure safety Socket devices enable simple installation on the ma

 Open the catalog to page 1
M.7 Pressure switches 30 A/F-2

Technical details Temperature resistance of sealing materials: Electrical values

 Open the catalog to page 2
M.7 Pressure switches 30 A/F-3

0159 Diaphragm / piston pressure switch up to 250 V • Aluminium housing • Changeover with silver contacts • Overpressure safety up to 200 / 600 bar1) • Switching point continuously adjustable by turning knurled screw whilst system in operation Refer to page 75 for the temperature range and application thresholds of sealing materials. 1 Static value. Dynamic value is 30-50 % lower. Values pertain to the hydraulic/pneumatic part of the pressure switch.

 Open the catalog to page 3
M.7 Pressure switches 30 A/F-4

0161 / 0162 Diaphragm / piston pressure switch up to 250 V • Aluminium housing • Changeover with silver contacts • Overpressure safety up to 200 / 600 bar11 • Socket device similar to DIN EN 1 75301 (DIN 43650) • Hysteresis adjustable at factory Tolerance at room Dimension A Article number With female G 1/4 thread 0161 Diaphragm pressure switches 200" Block style (with O-ring NBR 5 x 1.5 mm) 0162 Diaphragm pressure switches 200" 0162 Piston pressure switches 600" Seal material - Application areas Refer to page 75 for the temperature range and application thresholds of sealing materials. Article...

 Open the catalog to page 4
M.7 Pressure switches 30 A/F-5

Article number: 0175 Diaphragm pressure switches up to 250 V • For low pressure, high accuracy • Aluminium housing • Changeover with silver contacts • Overpressure safety up to 25 bar1) • Socket device similar to DIN EN 175301 (DIN 43650) • Hysteresis adjustable at factory 1 Adjusting the set point To adjust the set point, undo the locknut and adjust the set screw M16 using a screwdriver. Clockwise screwing increases the switching pressure. After adjusting, tighten the locknut again. 1 Static value. Dynamic value is 30-50 % lower. Values pertain to the hydraulic/pneumatic part of the pressure...

 Open the catalog to page 5

All SUCO Robert Scheuffele GmbH & Co. KG catalogs and technical brochures

*Prices are pre-tax. They exclude delivery charges and customs duties and do not include additional charges for installation or activation options. Prices are indicative only and may vary by country, with changes to the cost of raw materials and exchange rates.